Determination of Quaternary Ammonium Compounds in Oranges and Cucumbers Using QuEChERS Extraction and Ultra-Performance Liquid Chromatography/Tandem Mass Spectrometry

被引:18
|
作者
Javier Arrebola-Liebanas, Francisco [1 ]
Herrera Abdo, Maria Angeles [2 ]
Fernandez Moreno, Jose Luis [2 ]
Martinez-Vidal, Jose L. [1 ]
Garrido Frenich, Antonia [1 ]
机构
[1] Univ Almeria, Dept Chem & Phys, Res Ctr Agr & Food Biotechnol BITAL, Analyt Chem Area, E-04120 Almeria, Spain
[2] LAB, Lab Pesticide Residues, E-04131 Almeria, Spain
关键词
BENZALKONIUM CHLORIDE; PESTICIDE-RESIDUES; FOOD; IDENTIFICATION; COMMODITIES; LC/MS/MS; BIOCIDES; SAMPLES; WATER;
D O I
10.5740/jaoacint.SGEArrebolaLiebanas
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and fast method has been developed for determining relevant quaternary ammonium compounds in cucumber and orange samples. The target compounds were benzoalkonium chloride (BAC-10, BAC-12, BAC-14, and BAC-16), didecyldimethylammonium chloride, and benzethonium chloride, all frequently used biocides in the agrifood industry. An extraction based on the buffered Quick, Easy, Cheap, Effective, Rugged, and Safe method and determination by ultra-performance LC/MS/MS that eluted the biocides in less than 5 min Were used. The method was fully validated and implemented in a UNE-EN-ISO/IEC 17025 accredited laboratory for its application to the analysis of real samples. Performance characteristics of the method are reported, including an estimation of measurement uncertainty. Calibration curves were set between 0.01 and 0.150 mg/kg, LOD values were always between 0.4 and 1.0 mu g/kg, LOQ values were in the range 1-4 mu g/kg, recovery was between 81 and 115%, intraday and interday precision were always lower than 17% (expressed as RSD), and expanded uncertainty was always lower than 40%. The validation was accomplished for the two studied matrixes at spiking concentrations of 0.011 and 0.050 mg/kg. The method has been applied to the analysis of 30 cucumber and orange samples that were found to contain concentrations of BAC-12 that ranged between 0.015 and 0.210 mg/kg and of BAC-14 between 0.018 and 0.081 mg/kg.
引用
收藏
页码:1021 / 1026
页数:6
相关论文
共 50 条
  • [41] Determination of tetracyclines and their degradation products in soil using ultra-performance liquid chromatography-tandem mass spectrometry
    Chen L.
    Jia C.
    Liu B.
    Zhang Y.
    Earth Science Frontiers, 2019, 26 (06) : 1 - 6
  • [42] Determination of neonicotinoid insecticides residues in eels using subcritical water extraction and ultra-performance liquid chromatography-tandem mass spectrometry
    Xiao, Zhiming
    Yang, Yunxia
    Li, Yang
    Fan, Xia
    Ding, Shuangying
    ANALYTICA CHIMICA ACTA, 2013, 777 : 32 - 40
  • [43] Determination of sulfoxaflor residues in vegetables, fruits and soil using ultra-performance liquid chromatography/tandem mass spectrometry
    Xu, Jun
    Dong, Fengshou
    Liu, Xingang
    Li, Jing
    Li, Yuanbo
    Shan, Weili
    Zheng, Yongquan
    ANALYTICAL METHODS, 2012, 4 (12) : 4019 - 4024
  • [44] Trace Enantioselective Determination of Imidazolinone Herbicides in Various Food Matrices Using a Modified QuEChERS Method and Ultra-Performance Liquid Chromatography/Tandem Mass Spectrometry
    Rui Li
    Mingfeng Hu
    Kunfeng Liu
    Hui Zhang
    Xuesheng Li
    Huihua Tan
    Food Analytical Methods, 2019, 12 : 2647 - 2664
  • [45] Determination of Pydiflumetofen Residues in Some Foods of Plant and Animal Origin by QuEChERS Extraction Combined with Ultra-Performance Liquid Chromatography–Tandem Mass
    Lili Rong
    Xiaohu Wu
    Jun Xu
    Fengshou Dong
    Xingang Liu
    Yongquan Zheng
    Food Analytical Methods, 2018, 11 : 2682 - 2691
  • [46] Trace Enantioselective Determination of Imidazolinone Herbicides in Various Food Matrices Using a Modified QuEChERS Method and Ultra-Performance Liquid Chromatography/Tandem Mass Spectrometry
    Li, Rui
    Hu, Mingfeng
    Liu, Kunfeng
    Zhang, Hui
    Li, Xuesheng
    Tan, Huihua
    FOOD ANALYTICAL METHODS, 2019, 12 (12) : 2647 - 2664
  • [47] Identification of the hemoglobin variants by ultra-performance liquid chromatography - Tandem mass spectrometry
    Han, M.
    Lee, K.
    Jun, S.
    Song, S. H.
    Song, J.
    CLINICA CHIMICA ACTA, 2019, 493 : S61 - S61
  • [48] Evaluation of allergens in propolis by ultra-performance liquid chromatography/tandem mass spectrometry
    Gardana, Claudio
    Simonetti, Paolo
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (11) : 1675 - 1682
  • [49] Application of QuEchERS Method in Determining Imidaclothiz Residue in Soil and Citrus by Ultra-performance Liquid Chromatography Tandem Mass Spectrometry
    Qin, Li
    Liu, Fuguang
    Wu, Huiming
    Zhu, Guonian
    MATERIALS FOR ENVIRONMENTAL PROTECTION AND ENERGY APPLICATION, PTS 1 AND 2, 2012, 343-344 : 855 - 861
  • [50] Miniaturized liquid–liquid extraction coupled with ultra-performance liquid chromatography/tandem mass spectrometry for determination of topramezone in soil, corn, wheat, and water
    Yuanbo Li
    Fengshou Dong
    Xingang Liu
    Jun Xu
    Jing Li
    Caihong Lu
    Yunhao Wang
    Yongquan Zheng
    Analytical and Bioanalytical Chemistry, 2011, 400 : 3097 - 3107