Determination of Quaternary Ammonium Compounds in Oranges and Cucumbers Using QuEChERS Extraction and Ultra-Performance Liquid Chromatography/Tandem Mass Spectrometry

被引:18
作者
Javier Arrebola-Liebanas, Francisco [1 ]
Herrera Abdo, Maria Angeles [2 ]
Fernandez Moreno, Jose Luis [2 ]
Martinez-Vidal, Jose L. [1 ]
Garrido Frenich, Antonia [1 ]
机构
[1] Univ Almeria, Dept Chem & Phys, Res Ctr Agr & Food Biotechnol BITAL, Analyt Chem Area, E-04120 Almeria, Spain
[2] LAB, Lab Pesticide Residues, E-04131 Almeria, Spain
关键词
BENZALKONIUM CHLORIDE; PESTICIDE-RESIDUES; FOOD; IDENTIFICATION; COMMODITIES; LC/MS/MS; BIOCIDES; SAMPLES; WATER;
D O I
10.5740/jaoacint.SGEArrebolaLiebanas
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and fast method has been developed for determining relevant quaternary ammonium compounds in cucumber and orange samples. The target compounds were benzoalkonium chloride (BAC-10, BAC-12, BAC-14, and BAC-16), didecyldimethylammonium chloride, and benzethonium chloride, all frequently used biocides in the agrifood industry. An extraction based on the buffered Quick, Easy, Cheap, Effective, Rugged, and Safe method and determination by ultra-performance LC/MS/MS that eluted the biocides in less than 5 min Were used. The method was fully validated and implemented in a UNE-EN-ISO/IEC 17025 accredited laboratory for its application to the analysis of real samples. Performance characteristics of the method are reported, including an estimation of measurement uncertainty. Calibration curves were set between 0.01 and 0.150 mg/kg, LOD values were always between 0.4 and 1.0 mu g/kg, LOQ values were in the range 1-4 mu g/kg, recovery was between 81 and 115%, intraday and interday precision were always lower than 17% (expressed as RSD), and expanded uncertainty was always lower than 40%. The validation was accomplished for the two studied matrixes at spiking concentrations of 0.011 and 0.050 mg/kg. The method has been applied to the analysis of 30 cucumber and orange samples that were found to contain concentrations of BAC-12 that ranged between 0.015 and 0.210 mg/kg and of BAC-14 between 0.018 and 0.081 mg/kg.
引用
收藏
页码:1021 / 1026
页数:6
相关论文
共 26 条
  • [1] DIRECT DETERMINATION OF BENZALKONIUM CHLORIDE IN OPHTHALMIC SYSTEMS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    AMBRUS, G
    TAKAHASHI, LT
    MARTY, PA
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1987, 76 (02) : 174 - 176
  • [2] [Anonymous], 2012, SANCO124952011 EUR C
  • [3] Determination of quaternary ammonium compounds in seawater samples by solid-phase extraction and liquid chromatography-mass spectrometry
    Bassarab, P.
    Williams, D.
    Dean, J. R.
    Ludkin, E.
    Perry, J. J.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (05) : 673 - 677
  • [4] Assessment of uncertainty in pesticide multiresidue analytical methods:: main sources and estimation
    Cuadros-Rodríguez, L
    Torres, MEH
    López, EA
    González, FJE
    Liébanas, FJA
    Vidal, JLM
    [J]. ANALYTICA CHIMICA ACTA, 2002, 454 (02) : 297 - 314
  • [5] Ferrer I, 2002, ANAL CHEM, V74, P1275, DOI 10.1021/ac010969l
  • [6] Identification of alkyl dimethylbenzylammonium surfactants in water samples by solid-phase extraction followed by ion trap LC/MS and LC/MS/MS
    Ferrer, I
    Furlong, ET
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (12) : 2583 - 2588
  • [7] Development and validation of an HPLC/UV/MS method for simultaneous determination of 18 preservatives in grapefruit seed extract
    Ganzera, Markus
    Aberham, Anita
    Stuppner, Hermann
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (11) : 3768 - 3772
  • [8] High-throughput determination of pesticide residues in food commodities by use of ultra-performance liquid chromatography-tandem mass spectrometry
    Garrido Frenich, A.
    Martinez Vidal, J. L.
    Pastor-Montoro, E.
    Romero-Gonzalez, R.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (03) : 947 - 959
  • [9] Multiresidue Pesticide Analysis of Tuber and Root Commodities by QuEChERS Extraction and Ultra-Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry
    Garrido Frenich, Antonia
    Martin Fernandez, Maria Del Mar
    Diaz Moreno, Laura
    Martinez Vidal, Jose Luis
    Lopez-Gutierrez, Noelia
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (05) : 1319 - 1330
  • [10] DETERMINATION OF BENZALKONIUM CHLORIDE IN AQUEOUS OPHTHALMIC PREPARATIONS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GOMEZGOMAR, A
    GONZALEZAUBERT, MM
    GARCESTORRENTS, J
    COSTASEGARRA, J
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (8-12) : 871 - 876