摘要
Objective: Traditional operation frequently depends on experience of doctors and anatomic landmark visual observation, which often leads to deviation in acetabular prosthesis implantation. Computer navigation technique greatly improves accuracy of prosthesis implantation. The present meta-analysis aimed at assessing the accuracy and clinical significance of computer navigation for acetabular implantation. Methods: All studies published through March 2013 were systematically searched from PubMed, EMBnse, Science Direct, Cechrane library and other databases. Relevant journals or conference proceedings were searched manually. Only randomized controlled trials (RCTs) were included. Two independent reviewers identified and assessed the literature. Mean difference (MD) and Odds ratio (OR) of radiologic and clinical outcomes were pooled throughout the study between navigated and conventional THA. The meta-analysis was conducted by RevMan 5.1 software. Results: Thirteen studies were included in the review, with a total sample size of 1071 hips. Statistically significant differences were observed between navigated and conventional groups in the number of acetabular cups implanted beyond the safe zone [OR 0.13, 95% confidence interval (CI) (0.08-0.22); P < 0.00001], operative time [MD = 19.87 min, 95% CI (14.04-24.35); P < 0.00001] and leg length discrepancy [MD = -4.16 mm, 95% CI (-7.74 to -1.48); P = 0.004]. No significant differences in cup inclination, anteversion, incidence of postoperative dislocation or deep vein thrombosis were found. Conclusions: The present meta-analysis indicated that the use of computer navigation in patients undergoing THA improves the precision of acetabular cup placement by decreasing the number of outliers, and decreases leg length discrepancy. More high quality RCTs are required to further confirm our results. (C) 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:528 / 533
页数:6
相关论文
共 29 条
[21]   Limitations of Imageless Computer-Assisted Navigation for Total Hip Arthroplasty [J].
Lin, Fang ;
Lim, Dohyung ;
Wixson, Richard L. ;
Milos, Steven ;
Hendrix, Ronald W. ;
Makhsous, Mohsen .
JOURNAL OF ARTHROPLASTY, 2011, 26 (04) :596-605
[22]   Evaluation of Component Positioning in Primary Total Hip Arthroplasty Using an Imageless Navigation Device Compared With Traditional Methods [J].
Najarian, Brian C. ;
Kilgore, John E. ;
Markel, David C. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (01) :15-21
[23]   A Comparison between Robotic-assisted and Manual Implantation of Cementless Total Hip Arthroplasty [J].
Nakamura, Nobuo ;
Sugano, Nobuhiko ;
Nishii, Takashi ;
Kakimoto, Akihiro ;
Miki, Hidenobu .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (04) :1072-1081
[24]   Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty - A prospective, randomized, controlled study [J].
Parratte, Sebastien ;
Argenson, Jean-Noel A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (03) :494-499
[25]   Factors influencing cup orientation in 500 consecutive total hip replacements [J].
Rittmeister, M. ;
Callitsis, C. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (445) :192-196
[26]   Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position [J].
Sendtner, Ernst ;
Schuster, Tibor ;
Woerner, Michael ;
Kalteis, Thomas ;
Grifka, Joachim ;
Renkawitz, Tobias .
INTERNATIONAL ORTHOPAEDICS, 2011, 35 (06) :809-815
[27]   Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation [J].
Sugano, N. ;
Nishii, T. ;
Miki, H. ;
Yoshikawa, H. ;
Sato, Y. ;
Tamura, S. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (04) :455-460
[28]   Joint replacement-total hip replacement with CT-based navigation [J].
Widmer, KH ;
Grützner, PA .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 :84-89
[29]  
Yu Zhong, 2007, Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi, V21, P1057