Influence of soil resistivity on substations earth grounding system

被引:2
作者
Martineac, Corina [1 ]
Hasanah, Rini Nur [2 ]
机构
[1] Tech Univ Cluj Napoca, Elect Engn Fac, Cluj Napoca, Romania
[2] Univ Brawijaya, Elect Engn Dept, Malang, Indonesia
来源
PROCEEDINGS OF 2019 8TH INTERNATIONAL CONFERENCE ON MODERN POWER SYSTEMS (MPS) | 2019年
关键词
substation; touch voltage; step voltage; earth grounding; electrodes; resistivity; dispersion resistance;
D O I
10.1109/MPS.2019.8759796
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper emphasizes the variation of the grounding resistance for the components of the earth grounding, depending on the nature of the soil, that is based on the soil resistivity. It also presents the variation of the touch and step voltage values according to the same resistivity of the soil. The study can be expanded, making a database of table with results, allowing a quick reading of touch and step voltages for different configurations of substations and different soil types.
引用
收藏
页数:5
相关论文
共 50 条
[31]   New Grounding System of Wind Turbines [J].
Kargar, H. Kazemi ;
Sedighizadeh, M. ;
Mosavi, A. .
2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, :752-+
[32]   Effect of multilayer soil on the switching transient in substations [J].
Lu, TB ;
Qi, L ;
Cui, X .
IEEE TRANSACTIONS ON MAGNETICS, 2006, 42 (04) :843-846
[33]   The FEM Model of Grounding System Impulse Characteristic Considering Soil Frequency Dependence [J].
Li, Jingli ;
Qiao, Zhiyuan ;
Wu, Dongya .
2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014,
[34]   Novel method in decreasing grounding resistances of urban substations by utilizing peripheral geographical conditions [J].
Zeng, R ;
He, JL ;
Zou, J ;
Sheng, XF .
CONFERENCE RECORD OF THE 2002 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2002, :1113-1119
[35]   Influence of grounding impedance model on lightning protection analysis of transmission system [J].
Wu, Jinpeng ;
He, Jinliang ;
Zhang, Bo ;
Zeng, Rong .
ELECTRIC POWER SYSTEMS RESEARCH, 2016, 139 :133-138
[36]   Parameters Affecting the Resistance of Earth Grounding Installation [J].
Viorel, Rusu Alexandru ;
Lucache, Dorin Dumitru .
2018 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE), 2018, :958-962
[37]   Comparison of 161/69-kV grounding grid design between indoor-type and outdoor-type substations [J].
Lee, CH ;
Chang, CN .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) :1385-1393
[38]   Seasonal influences on safety of substation grounding system [J].
He, JL ;
Zeng, R ;
Gao, YQ ;
Tu, YP ;
Sun, WM ;
Zou, J ;
Guan, ZC .
IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (03) :788-795
[39]   An Identification Method for Ground Potential of Grounding Grid in Urban Substations Considering Metro Stray Current [J].
Ma, Yidi ;
Lin, Sheng ;
Zou, Quande ;
Li, Yuda ;
Zhou, Qi .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
[40]   Effectiveness of the industry standard peninsula technique for grounding the neutrals of shunt capacitors in high voltage substations [J].
Dawalibi, Farid. P. ;
Tee, Sharon ;
Fortin, Simon ;
Grignon, Nathalie .
2006 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION. VOLS 1-5, 2006, :1996-+