Influence of soil resistivity on substations earth grounding system

被引:2
|
作者
Martineac, Corina [1 ]
Hasanah, Rini Nur [2 ]
机构
[1] Tech Univ Cluj Napoca, Elect Engn Fac, Cluj Napoca, Romania
[2] Univ Brawijaya, Elect Engn Dept, Malang, Indonesia
来源
PROCEEDINGS OF 2019 8TH INTERNATIONAL CONFERENCE ON MODERN POWER SYSTEMS (MPS) | 2019年
关键词
substation; touch voltage; step voltage; earth grounding; electrodes; resistivity; dispersion resistance;
D O I
10.1109/MPS.2019.8759796
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper emphasizes the variation of the grounding resistance for the components of the earth grounding, depending on the nature of the soil, that is based on the soil resistivity. It also presents the variation of the touch and step voltage values according to the same resistivity of the soil. The study can be expanded, making a database of table with results, allowing a quick reading of touch and step voltages for different configurations of substations and different soil types.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Significance of Localized Soil Resistivity in Designing a Grounding System
    Lim, S. C.
    Gomes, C.
    Nourirad, G.
    Kadir, M. Z. A. A.
    2014 IEEE 8TH INTERNATIONAL POWER ENGINEERING AND OPTIMIZATION CONFERENCE (PEOCO), 2014, : 324 - 329
  • [2] Evaluation of earth resistivity for grounding systems in non-uniform soil structure
    Ghourab, ME
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 1996, 6 (03): : 195 - 200
  • [3] Grounding system design method in high soil resistivity regions
    Zhuang, Chi-Jie
    Zeng, Rong
    Zhang, Bo
    He, Jin-Liang
    Gaodianya Jishu/High Voltage Engineering, 2008, 34 (05): : 893 - 897
  • [4] DESIGNING SAFE AND RELIABLE GROUNDING IN AC SUBSTATIONS WITH POOR SOIL RESISTIVITY: AN INTERPRETATION OF IEEE STD. 80
    Ackerman, Andrew
    Sen, P. K.
    Oertli, Clifton
    2012 RECORD OF CONFERENCE PAPERS INDUSTRY APPLICATIONS SOCIETY 59TH ANNUAL IEEE PETROLEUM AND CHEMICAL INDUSTRY TECHNICAL CONFERENCE (PCIC), 2012,
  • [5] Designing Safe and Reliable Grounding in AC Substations With Poor Soil Resistivity: An Interpretation of IEEE Std. 80
    Ackerman, Andrew
    Sen, P. K.
    Oertli, Clifton
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (04) : 1883 - 1889
  • [6] The influence of seasonal soil moisture on the behavior of soil resistivity and power distribution grounding systems
    Coelho, Vilson Luiz
    Piantini, Alexandre
    Almaguer, Hugo A. D.
    Coelho, Rafael A.
    Boaventura, Wallace do C.
    Paulino, Jose Osvaldo S.
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 118 : 76 - 82
  • [7] Application of Fuzzy Modeling to Identify the Soil Resistivity of Dynamic Grounding System
    Fan Shao-sheng
    Wang bing
    INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION, VOL 1, PROCEEDINGS, 2008, : 855 - 858
  • [8] A Study on Electrical Resistivity Characteristics of Pakistani Coal Char for Earth Grounding System
    Zafar, M.
    Rauf, A.
    Qureshi, H. U.
    Rizwan, M.
    Siddique, K.
    Imran, S. M.
    Mudassar, M.
    JOURNAL OF THE PAKISTAN INSTITUTE OF CHEMICAL ENGINEERS, 2023, 51 (01): : 21 - 30
  • [9] Negative Temperature Characteristics of Soil Resistivity and Influence of Frozen Soil on Impulse Response of Grounding Electrode
    Yuan T.
    Ren J.
    Sima W.
    Chang F.
    Cai Y.
    Xiao X.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (05): : 1474 - 1485
  • [10] Optimized Design of Earthing System for Substations with High Soil Resistivity and Limited Plot Area
    Bonda, Prudhvi Raj
    Mishra, Mahesh K.
    2018 20TH NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2018,