High-resolution Schottky CdTe diode detector

被引:89
作者
Takahashi, T [1 ]
Mitani, T
Kobayashi, Y
Kouda, M
Sato, G
Watanabe, S
Nakazawa, K
Okada, Y
Funaki, M
Ohno, R
Mori, K
机构
[1] Inst Space & Astronaut Sci, Sagamihara, Kanagawa 2298510, Japan
[2] Univ Tokyo, Dept Phys, Bunkyo Ku, Tokyo 1130033, Japan
[3] ACRORAD, Okinawa 9042234, Japan
[4] Clear Pulse Ltd, Tokyo 1430024, Japan
关键词
CdTe; CdZnTe; gamma-ray; pixel detector; X-ray;
D O I
10.1109/TNS.2002.1039655
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We describe recent progress on,the use of Schottky CdTe diode detectors for spectrometry. The low leakage current of the CdTe diode allows us to apply a much higher bias voltage than was possible with previous CdTe detectors. For a relatively thin detector of 0.5-1 mm thickness, the high bias voltage results in a high electric field in the device. Both the improved charge-collection efficiency and the low-leakage current lead to an energy resolution of better than 600 eV full-width at half-maximum at 60 keV for a 2 x 2 mm(2) device without any charge-loss correction electronics. Large-area detectors with dimensions of 21 x 21 mm2 are now available with an energy resolution of similar to2.8 keV. Long-term stability can be easily attained for relatively thin (< 1 mm). detectors if they are cooled or operated under a high bias voltage.
引用
收藏
页码:1297 / 1303
页数:7
相关论文
共 20 条
[1]   Cooled CdZnTe detectors for X-ray astronomny [J].
Bale, G ;
Holland, A ;
Seller, P ;
Lowe, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) :150-154
[2]   TIME-DEPENDENT POLARIZATION OF CDTE GAMMA-RAY DETECTORS [J].
BELL, RO ;
ENTINE, G ;
SERREZE, HB .
NUCLEAR INSTRUMENTS & METHODS, 1974, 117 (01) :267-271
[3]   CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems [J].
Eisen, Y ;
Shor, A ;
Mardor, I .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (01) :158-170
[4]   Growth and characterization of CdTe single crystals for radiation detectors [J].
Funaki, M ;
Ozaki, T ;
Satoh, K ;
Ohno, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) :120-126
[5]   Performance of a high resolution CdTe and CdZnTe P-I-N detectors [J].
Khusainov, A ;
Arlt, R ;
Siffert, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :245-251
[6]   CADMIUM TELLURIDE DETECTORS WITH THERMOELECTRIC COOLING [J].
KHUSAINOV, AK .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :335-340
[7]   POLARIZATION PHENOMENA IN CDTE NUCLEAR RADIATION DETECTORS [J].
MALM, HL ;
MARTINI, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) :322-330
[8]   Performance of a new schottky CdTe detector for hard X-ray spectroscopy [J].
Matsumoto, C ;
Takahashi, T ;
Takizawa, K ;
Ohno, R ;
Ozaki, T ;
Mori, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :428-432
[9]   Improved spectrometric performance of CdTe radiation detectors in a p-i-n design [J].
Niraula, M ;
Mochizuki, D ;
Aoki, T ;
Hatanaka, Y ;
Tomita, Y ;
Nihashi, T .
APPLIED PHYSICS LETTERS, 1999, 75 (15) :2322-2324
[10]   HIGH-QUALITY CDTE AND ITS APPLICATION TO RADIATION DETECTORS [J].
OHMORI, M ;
IWASE, Y ;
OHNO, R .
MATERIALS SCIENCE AND ENGINEERING B-SOLID STATE MATERIALS FOR ADVANCED TECHNOLOGY, 1993, 16 (1-3) :283-290