Energy Consumption Comparison of a Single Variable-Speed Pump and a System of Two Pumps: Variable-Speed and Fixed-Speed

被引:27
作者
Oshurbekov, Safarbek [1 ]
Kazakbaev, Vadim [1 ]
Prakht, Vladimir [1 ]
Dmitrievskii, Vladimir [1 ]
Gevorkov, Levon [2 ]
机构
[1] Ural Fed Univ, Dept Elect Engn, Ekaterinburg 620002, Russia
[2] Univ West Bohemia, Fac Elect Engn, Plzen 30100, Czech Republic
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 24期
关键词
centrifugal pump; energy efficiency; induction motor; throttling control; variable speed control; STATION; OPTIMIZATION;
D O I
10.3390/app10248820
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application The presented results can be used to assess the energy-saving potential of various topologies of multi-pump pumping stations. The energy efficiency of a multi-pump system consisting of two low-power (0.75 kW) pumps operating in parallel mode and a single-pump mechanism (1.5 kW) is compared in this study. For this purpose, mathematical models, experimental data, and data retrieved from the manuals provided by the pump manufacturers are used. The single-pump system is fed by a single variable speed drive. A multi-pump system running in parallel mode consists of two pumps. One of them is driven by an induction motor connected directly to the electrical grid and equipped with a throttle. Another pump is actuated by an induction motor fed by a variable speed drive. The flowrate of the liquid in the multi-pump is controlled with the help of speed variation and throttling. In the case of the single-pump system the conventional speed control method is applied during the analysis. For both pump system topologies, the daily and annual energy consumption is obtained. As a result of conducted calculations, it was shown that the multi-pump provides 29.8% savings in comparison to the single-pump system in the case of a typical flowrate profile.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 30 条
  • [21] Parametric analysis of pumping station with parallel-configured centrifugal pumps towards self-learning applications
    Olszewski, Pawel
    Arafeh, Jamal
    [J]. APPLIED ENERGY, 2018, 231 : 1146 - 1158
  • [22] Genetic optimization and experimental verification of complex parallel pumping station with centrifugal pumps
    Olszewski, Pawel
    [J]. APPLIED ENERGY, 2016, 178 : 527 - 539
  • [23] Optimal Pipe Sizing and Operation of Multistage Centrifugal Pumps for Water Supply
    Pandey, Sonam
    Singh, R. P.
    Mahar, P. S.
    [J]. JOURNAL OF PIPELINE SYSTEMS ENGINEERING AND PRACTICE, 2020, 11 (02)
  • [24] Safin N., 2018, P 2018 25 INT WORKSH
  • [25] AFD synchronizing applications: Identifying potential, methods and benefits
    Seggewiss, G
    Kottwitz, R
    McIntosh, DJ
    [J]. INDUSTRY APPLICATIONS SOCIETY 48TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 2001, : 83 - 89
  • [26] Stoffel B., 2015, Assessing the Energy Efficiency of Pumps and Pump Units: Background and Methodology
  • [27] Viholainen J., 2014, THESIS
  • [28] Energy-efficient control strategy for variable speed-driven parallel pumping systems
    Viholainen, Juha
    Tamminen, Jussi
    Ahonen, Tero
    Ahola, Jero
    Vakkilainen, Esa
    Soukka, Risto
    [J]. ENERGY EFFICIENCY, 2013, 6 (03) : 495 - 509
  • [29] The Relationship Between the Maximum Efficiency and the Flow of Centrifugal Pumps in Parallel Operation
    Wen, Yi
    Zhang, Xiaochu
    Wang, Pu
    [J]. JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2010, 132 (03): : 0345011 - 0345012
  • [30] Optimization Research of Parallel Pump System for Improving Energy Efficiency
    Wu, Peng
    Lai, Zhounian
    Wu, Dazhuan
    Wang, Leqin
    [J]. JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2015, 141 (08)