Robust prescan calibration for multiple spin-echo sequences: application to FSE and b-SSFP

被引:12
作者
Bowen, Chris V. [1 ]
Gati, Joseph S.
Menon, Ravi S.
机构
[1] CNR, Inst Biodiagnost Atlantic, Halifax, NS B3H 3A7, Canada
[2] John P Robarts Res Inst, Lab Funct Magnet Resonance Res, London, ON N6A 5K8, Canada
[3] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5K8, Canada
[4] Univ Western Ontario, Dept Diagnost Radiol & Nucl Med, London, ON N6A 5K8, Canada
基金
加拿大健康研究院;
关键词
fast spin echo; TrueFISP; FIESTA; SSFP; artifact; prescan; knee; MRI;
D O I
10.1016/j.mri.2006.04.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The collection of fast imaging techniques that use multiple spin-echo (MSE) sequences relies on a precise phase relationship between spin echoes and stimulated echoes that form along the radiofrequency refocusing pulse train. Failure to achieve this condition produces dark banding artifacts that result from destructive interference between signal coherence pathways. Satisfying this condition on the microsecond timescale required is technically challenging for conditions involving strong diffusion-weighted gradients, for arbitrary orientation acquisitions and at large field strengths with high-resolution acquisitions. Two clinically significant MSE sequences, fast spin echo (FSE) and balanced steady-state free precession (b-SSFP), are investigated in this work using a 4-T whole-body scanner. We developed a readout-projection-based prescan technique that ensures coherent signal formation by utilizing banding artifacts to automatically adjust gradient balance. Subsequent image acquisition using the results of this prescan permits the formation of coherent-echo images, which are robust under challenging imaging conditions. The robustness of this approach is demonstrated for FSE and b-SSFP images obtained from the knees of human volunteers. We believe that the use of this prescan calibration technique for the alignment of signal pools in MSE sequences is critical at high fields and will facilitate the implementation of high-quality clinically significant sequences such as FSE and b-SSFP. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:857 / 867
页数:11
相关论文
共 36 条
  • [1] Phase insensitive preparation of single-shot RARE: Application to diffusion imaging in humans
    Alsop, DC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) : 527 - 533
  • [2] Analysis of multiple-acquisition SSFP
    Bangerter, NK
    Hargreaves, BA
    Vasanawala, SS
    Pauly, JM
    Gold, GE
    Nishimura, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) : 1038 - 1047
  • [3] On the application of a non-CPMG single-shot fast spin-echo sequence to diffusion tensor MRI of the human brain
    Bastin, ME
    Le Roux, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) : 6 - 14
  • [4] DIFFUSION-WEIGHTED MR MICROSCOPY WITH FAST SPIN-ECHO
    BEAULIEU, CF
    ZHOU, XH
    COFER, GP
    JOHNSON, GA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) : 201 - 206
  • [5] Analysis and compensation of eddy currents in balanced SSFP
    Bieri, O
    Markl, M
    Scheffler, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) : 129 - 137
  • [6] THE FIELD-DEPENDENCE OF NMR IMAGING .1. LABORATORY ASSESSMENT OF SIGNAL-TO-NOISE RATIO AND POWER DEPOSITION
    CHEN, CN
    SANK, VJ
    COHEN, SM
    HOULT, DI
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) : 722 - 729
  • [7] FUNCTIONAL NMR IMAGING USING FAST SPIN-ECHO AT 1.5 T
    CONSTABLE, RT
    KENNAN, RP
    PUCE, A
    MCCARTHY, G
    GORE, JC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) : 686 - 690
  • [8] ERRORS IN T2 ESTIMATION USING MULTISLICE MULTIPLE-ECHO IMAGING
    CRAWLEY, AP
    HENKELMAN, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (01) : 34 - 47
  • [9] Reduction of transient signal oscillations in True-FISP using a linear flip angle series magnetization preparation
    Deshpande, VS
    Chung, YC
    Zhang, Q
    Shea, SM
    Li, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) : 151 - 157
  • [10] 3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries
    Deshpande, VS
    Shea, SM
    Laub, G
    Simonetti, OP
    Finn, JP
    Li, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 494 - 502