Sampling 4-chlorophenol in water by DGT technique with molecularly imprinted polymer as binding agent and nylon membrane as diffusive layer

被引:67
作者
Dong, Jia [1 ]
Fan, Hongtao [1 ,2 ]
Sui, Dianpeng [1 ]
Li, Liangchen [1 ]
Sun, Ting [1 ]
机构
[1] Northeastern Univ, Dept Chem, Coll Sci, Shenyang 110032, Peoples R China
[2] Shenyang Univ Chem Technol, Coll Appl Chem, Shenyang 110142, Peoples R China
基金
美国国家科学基金会;
关键词
Diffusive gradients in thin films; 4-Chlorophenol; Nylon membrane; Molecularly imprinted polymer; SOLID-PHASE EXTRACTION; THIN-FILMS TECHNIQUE; DISSOLVED REACTIVE PHOSPHORUS; IN-SITU MEASUREMENT; PERFORMANCE-CHARACTERISTICS; SELECTIVE BINDING; NATURAL-WATERS; TRACE-METALS; SCHIFF-BASE; GRADIENTS;
D O I
10.1016/j.aca.2014.03.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the first time, a diffusive gradients in thin films (DGT) device using molecularly imprinted polymer (MIP) as the binding agent and nylon membrane (NM) as the diffusive layer (NM-MIP-DGT) has been developed for sampling 4-chlorophenol (4-CP) in water. The MIP was prepared by precipitation polymerization with methacrylic acid as monomer and ethyleneglycoldimethacrylate as cross-linker. The diffusion coefficient of 4-CP through NM was obtained to be 0.788 +/- 0.040 mu cm(2) s (1) by diffusion cell method. The ratio was 1.01 + 0.05 (mean + standard deviation) for the concentration of 4-CP sampled by NM-MIP-DGT and analyzed by HPLC method to the total concentration of 4-CP in the synthetic solution where free 4-CP species dominated. The results showed that NM-MIP-DGT could sample 4-CP in synthetic solution accurately. The performance of NM-MIP-DGT for sampling 4-CP was independent of pH in the range of 3-7 and ionic strength in the range of 0.0001-0.1 mol L (1) NaCl solution. The concentration of free form of 4-CP sampled by NM-MIP-DGT decreased with the increasing concentration of dissolved organic carbon in different water samples due to the electrostatic interaction of natural organic compounds with 4-CP. 1.8 mg L (1) of the free form of 4-CP was determined by HPLC which was sampled by NM-MIP-DGT in an intermediate untreated industrial effluent. The NM-MIP-DGT can be a potential passive tool for sampling the free form of 4-CP in water. (C) 2014 Published by Elsevier B. V.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 56 条
[1]   Remediation of phenol-contaminated water by adsorption using poly(methyl methacrylate) (PMMA) [J].
Al-Muhtaseb, Ala'a H. ;
Ibrahim, Khalid A. ;
Albadarin, Ahmad B. ;
Ali-Khashman, Omar ;
Walker, Gavin M. ;
Ahmad, Mohammad N. M. .
CHEMICAL ENGINEERING JOURNAL, 2011, 168 (02) :691-699
[2]   Chemcatcher® and DGT passive sampling devices for regulatory monitoring of trace metals in surface water [J].
Allan, Ian J. ;
Knutsson, Jesper ;
Guigues, Nathalie ;
Mills, Graham A. ;
Fouillac, Anne-Marie ;
Greenwood, Richard .
JOURNAL OF ENVIRONMENTAL MONITORING, 2008, 10 (07) :821-829
[3]   Sulphur cycling in organic-rich marine sediments from a Scottish fjord [J].
Bottrell, Simon H. ;
Mortimer, Robert J. G. ;
Davies, Ian M. ;
Harvey, S. Martyn ;
Krom, Michael D. .
SEDIMENTOLOGY, 2009, 56 (04) :1159-1173
[4]   On-line solid-phase extraction with molecularly imprinted polymers to selectively extract substituted 4-chlorophenols and 4-nitrophenol from water [J].
Caro, E ;
Marcé, RM ;
Cormack, PAG ;
Sherrington, DC ;
Borrull, F .
JOURNAL OF CHROMATOGRAPHY A, 2003, 995 (1-2) :233-238
[5]   Performance characteristics for the measurement of Cs and Sr by diffusive gradients in thin films (DGT) [J].
Chang, LY ;
Davison, W ;
Zhang, H ;
Kelly, M .
ANALYTICA CHIMICA ACTA, 1998, 368 (03) :243-253
[6]   Effective concentration difference model to study the effect of various factors on the effective diffusion coefficient in the dialysis membrane [J].
Chen, Hong ;
Sun, Ting ;
Sui, Dianpeng ;
Dong, Jia .
ANALYTICA CHIMICA ACTA, 2011, 698 (1-2) :27-35
[7]   Methylmercury speciation in the dissolved phase of a stratified lake using the diffusive gradient in thin film technique [J].
Clarisse, Olivier ;
Foucher, Delphine ;
Hintelmann, Holger .
ENVIRONMENTAL POLLUTION, 2009, 157 (03) :987-993
[8]   PERFORMANCE-CHARACTERISTICS OF GEL PROBES USED FOR MEASURING THE CHEMISTRY OF PORE WATERS [J].
DAVISON, W ;
ZHANG, H ;
GRIME, GW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (09) :1623-1632
[9]   Paper-based diffusive gradients in thin films technique coupled to energy dispersive X-ray fluorescence spectrometry for the determination of labile Mn, Co, Ni, Cu, Zn and Pb in river water [J].
de Almeida, Eduardo ;
do Nascimento Filho, Virgilio Franco ;
Menegario, Amauri Antonio .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 71-72 :70-74
[10]   Extraction and preconcentration techniques for chromatographic determination of chlorophenols in environmental and food samples [J].
de Morais, Paulo ;
Stoichev, Teodor ;
Basto, M. Clara P. ;
Vasconcelos, M. Teresa S. D. .
TALANTA, 2012, 89 :1-11