Chewing simulation of zirconia implant supported restorations

被引:15
作者
Rohr, Nadja [1 ]
Balmer, Marc [2 ]
Mueller, Johannes A. [1 ]
Maertin, Sabrina [3 ]
Fischer, Jens [1 ,3 ]
机构
[1] Univ Basel, Univ Ctr Dent Med, Dept Reconstruct Dent, Div Dent Mat & Engn, Hebelstr 3, CH-4056 Basel, Switzerland
[2] Univ Zurich, Ctr Dent Med, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Zurich, Switzerland
[3] Vita Zahnfabr, Bad Sackingen, Germany
关键词
Zirconia implant; Chewing simulation; Fracture load; Retentive force; Abrasion; LITHIUM DISILICATE CROWNS; IN-VITRO PERFORMANCE; ALL-CERAMIC CROWNS; SINGLE CROWNS; FRACTURE STRENGTH; FAILURE ANALYSIS; BOND STRENGTH; CEMENT TYPE; TITANIUM; RESISTANCE;
D O I
10.1016/j.jpor.2019.02.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To test three potential prosthetic material options for zirconia implants in regard to their mechanical properties, loading and retention capacity as well as to record abrasion after chewing simulation followed by thermocyclic aging. Methods: Molar crowns (n = 96) of three different computer-aided design/computer-aided manufacturing (CAD/CAM) materials were produced and cemented on zirconia implants (ceramic.implant, Vita) with a diameter of 4.5 mm. Monolithic zirconia (Vita YZ [YZ] with RelyX Unicem 2 Automix [RUN], polymerinfiltrated ceramic (Vita Enamic [VE]) with Vita Adiva F-Cem [VAF] and acrylate polymer (CAD Temp [CT]) with RelyX Ultimate [RUG Fracture load and retentive force of the crowns were measured after 24 h water storage at 37 degrees C and after a chewing simulation followed by thermocyclic aging. Abrasion was recorded by matching stereolithography-data of the crowns obtained before and after chewing simulation. Additionally, the mechanical properties and bonding capabilities of the crown and cement materials were assessed. Results: Fracture load values were significantly highest for YZ > VE = CT. Retention force values did not differ significantly between the materials. The aging procedure did not affect the fracture load values nor the retention force significantly. Abrasion depth of the crowns was lowest for YZ followed by VE and CT. On unpolished crowns, abrasion of YZ and VE tended to be higher than on polished specimens. Conclusions: Based on the obtained in-vitro results, all tested materials can be recommended for the use on zirconia implants, although CT is only approved for temporary crowns. The loading and retention capacity of the materials were not significantly affected by aging. (C) 2019 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:361 / 367
页数:7
相关论文
共 44 条
[1]   Three-year analysis of zirconia implants used for single-tooth replacement and three-unit fixed dental prostheses: A prospective multicenter study [J].
Balmer, Marc ;
Spies, Benedikt C. ;
Vach, Kirstin ;
Kohal, Ralf-Joachim ;
Hammerle, Christoph H. F. ;
Jung, Ronald E. .
CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (03) :290-299
[2]   Biomechanical properties of polymer-infiltrated ceramic crowns on one-piece zirconia implants after long-term chewing simulation [J].
Baumgart, Pia ;
Kirsten, Holger ;
Haak, Rainer ;
Olms, Constanze .
INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
[3]   Durability of Resin-Zirconia Bonds Produced Using Methods Available in Dental Practice [J].
Boemicke, Wolfgang ;
Schuerz, Alexander ;
Krisam, Johannes ;
Rammelsberg, Peter ;
Rues, Stefan .
JOURNAL OF ADHESIVE DENTISTRY, 2016, 18 (01) :17-27
[4]   Development of binary and ternary titanium alloys for dental implants [J].
Cordeiro, Jairo M. ;
Beline, Thamara ;
Ribeiroc, Ana Lucia R. ;
Rangel, Elidiane C. ;
da Cruz, Nilson C. ;
Landers, Richard ;
Faverani, Leonardo P. ;
Vaz, Luis Geraldo ;
Fais, Laiza M. G. ;
Vicente, Fabio B. ;
Grandini, Carlos R. ;
Mathew, Mathew T. ;
Sukotjo, Cortino ;
Barao, Valentim A. R. .
DENTAL MATERIALS, 2017, 33 (11) :1244-1257
[5]   Fracture Resistance of Molar Crowns Fabricated with Monolithic All-Ceramic CAD/CAM Materials Cemented on Titanium Abutments: An In Vitro Study [J].
Dogan, Derya Ozdemir ;
Gorler, Oguzhan ;
Mutaf, Burcu ;
Ozcan, Mutlu ;
Eyuboglu, Gunes Bulut ;
Ulgey, Melih .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (04) :309-314
[6]   Biting and chewing in overdentures, full dentures, and natural dentitions [J].
Fontijn-Tekamp, FA ;
Slagter, AP ;
Van Der Bilt, A ;
Van 'T Hof, MA ;
Witter, DJ ;
Kalk, W ;
Jansen, JA .
JOURNAL OF DENTAL RESEARCH, 2000, 79 (07) :1519-1524
[7]   Influence of low-temperature degradation on the wear characteristics of zirconia against polymer-infiltrated ceramic-network material [J].
Hao, Zhichao ;
Ma, Yuanyuan ;
Liu, Wenjia ;
Meng, Yukun ;
Nakamura, Keisuke ;
Shen, Jiefei ;
Wang, Hang .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (04) :596-602
[8]   A systematic review of the clinical survival of zirconia implants [J].
Hashim, Dena ;
Cionca, Norbert ;
Courvoisier, Delphine S. ;
Mombelli, Andrea .
CLINICAL ORAL INVESTIGATIONS, 2016, 20 (07) :1403-1417
[9]   The effect of different pretreatment methods of PMMA-based crowns on the long-term tensile bond strength to dentin abutments [J].
Keul, Christine ;
Kohen, Daliah ;
Eichberger, Marlis ;
Roos, Malgorzata ;
Gernet, Wolfgang ;
Stawarczyk, Bogna .
CLINICAL ORAL INVESTIGATIONS, 2015, 19 (01) :35-43
[10]   All-Ceramic Single Crown Restauration of Zirconia Oral Implants and Its Influence on Fracture Resistance: An Investigation in the Artificial Mouth [J].
Kohal, Ralf-Joachim ;
Kilian, Jolanta Bernadette ;
Stampf, Susanne ;
Spies, Benedikt Christopher .
MATERIALS, 2015, 8 (04) :1577-1589