Biomechanical assessment of healthy and keratoconic corneas (with/without crosslinking) using dynamic ultrahigh-speed Scheimpflug technology and the relevance of the parameter (A1L-A2L)

被引:17
作者
Fuchsluger, Thomas A. [1 ,2 ]
Brettl, Susanne [3 ,4 ]
Geerling, Gerd [2 ]
Kaisers, Wolfgang [5 ]
Zeitz, Philipp Franko [4 ]
机构
[1] Friedrich Alexander Univ Nuremberg Erlangen, Erlangen Univ Hosp, Dept Ophthalmol, Erlangen, Germany
[2] Heinrich Heine Univ Dusseldorf, Dusseldorf Univ Hosp, Dept Ophthalmol, Dusseldorf, Germany
[3] Charite Univ Med Berlin, Dept Ophthalmol, Berlin, Germany
[4] Zeitz Franko Zeitz Ophthalmol Specialists Practic, Dusseldorf, Germany
[5] Heinrich Heine Univ Dusseldorf, Dusseldorf Univ Hosp, Dept Anesthesiol, Dusseldorf, Germany
关键词
INTRAOCULAR-PRESSURE; DEFORMATION;
D O I
10.1136/bjophthalmol-2017-311627
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To examine corneal biomechanics in healthy and keratoconic eyes, with or without crosslinking obtained by ultrahigh-speed Scheimpflug measurements (Corvis ST). Methods One hundred and seventeen eyes were studied in three groups: group 1 (n=39) contained keratoconic eyes without crosslinking. Group 2 (CXL; n=28) comprised keratoconic eyes after crosslinking. These were compared with a control group (n=50 matched healthy eyes). In addition, 10 keratoconus patients, before and after CXL treatment, respectively, were examined. Results The novel parameter A1L-A2L demonstrated highly significant differences between crosslinked corneas and untreated keratoconic or healthy corneas. Velocity during second applanation (A2V) and deformation amplitude (DA) were significantly increased in crosslinked keratoconic eyes both compared with untreated keratoconic eyes and with healthy controls. Radius at highest curvature also was significant among all groups. Inward applanation length (A1L) was significantly increased in controls, whereas outward applanation length (A2L) was significantly reduced in crosslinked keratoconic eyes compared with both other groups. The follow-up analysis revealed statistically significant changes in pachymetry and intraocular pressure and showed tendencies towards significance in applanation times 1 and 2 and in DA. Conclusions Both A2V and A2L are viable parameters to discriminate healthy from keratoconic but also crosslinked from non-crosslinked keratoconic corneas. The difference of A1L-A2L could reliably discriminate crosslinked from non-crosslinked and healthy corneas. Follow-up examination in a small cohort allows distinction between crosslinked and untreated keratoconus in follow-up examinations. The difference of A1L-A2L could reliably discriminate crosslinked from non-crosslinked and healthy corneas. Measurements of corneal deformation using dynamic ultrahigh-speed Scheimpflug technology are reproducible and provide useful information about keratoconus assessment and biomechanics. Therefore, the Corvis ST seems to provide useful technology to monitor therapeutic success of crosslinking treatment.
引用
收藏
页码:558 / 564
页数:7
相关论文
共 18 条
[1]   Biomechanical Responses of Healthy and Keratoconic Corneas Measured Using a Noncontact Scheimpflug-Based Tonometer [J].
Ali, Noor Q. ;
Patel, Dipika V. ;
McGhee, Charles N. J. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (06) :3651-3659
[2]  
Ambrosio R, 2011, ASCRS ASOA SAN DIEG, P8
[3]   Dynamic Scheimpflug-based Assessment of Keratoconus and the Effects of Corneal Cross-linking [J].
Bak-Nielsen, Sashia ;
Pedersen, Iben B. ;
Ivarsen, Anders ;
Hjortdal, Jesper .
JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (06) :408-414
[4]   Corneal Deformation Measurement Using Scheimpflug Noncontact Tonometry [J].
Hon, Ying ;
Lam, Andrew K. C. .
OPTOMETRY AND VISION SCIENCE, 2013, 90 (01) :E1-E8
[5]   Corneal Biomechanics as a Function of Intraocular Pressure and Pachymetry by Dynamic Infrared Signal and Scheimpflug Imaging Analysis in Normal Eyes [J].
Huseynova, Tukezban ;
Waring, George O. ;
Roberts, Cynthia ;
Krueger, Ronald R. ;
Tomita, Minoru .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (04) :885-893
[6]  
Kling S, 2013, INVEST OPHTH VIS SCI, V54, P5078, DOI 10.1167/iovs.13-12509
[7]   Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones [J].
Lanza, Michele ;
Cennamo, Michela ;
Iaccarino, Stefania ;
Irregolare, Carlo ;
Rechichi, Miguel ;
Bifani, Mario ;
Carnevale, Ugo Antonello Gironi .
BIOMED RESEARCH INTERNATIONAL, 2014, 2014
[8]   An Ultra-High-Speed Scheimpflug Camera for Evaluation of Corneal Deformation Response and Its Impact on IOP Measurement [J].
Leung, Christopher Kai-Shun ;
Ye, Cong ;
Weinreb, Robert N. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (04) :2885-2892
[9]   Repeatability of Ocular Biomechanical Data Measurements With a Scheimpflug-Based Noncontact Device on Normal Corneas [J].
Nemeth, Gabor ;
Hassan, Ziad ;
Csutak, Adrienne ;
Szalai, Eszter ;
Berta, Andras ;
Modis, Laszlo, Jr. .
JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (08) :558-563
[10]   KISA% index: A quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus [J].
Rabinowitz, YS ;
Rasheed, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (10) :1327-1335