Intrinsic Optical Properties of Boston Keratoprosthesis

被引:2
|
作者
Hui, Pui-Chuen [1 ,2 ]
Pereira, Leonardo A. [1 ,3 ]
Dore, Renald [4 ]
Chen, Shengtong [4 ]
Taniguchi, Elise [1 ,2 ]
Chodosh, James [1 ]
Dohlman, Claes H. [1 ,2 ]
Paschalis, Eleftherios, I [1 ,2 ]
机构
[1] Harvard Med Sch, Dept Ophthalmol, Massachusetts Eye & Ear, Boston, MA 02114 USA
[2] Harvard Med Sch, Schepens Eye Res Inst, Boston Keratoprosthesis Lab, Massachusetts Eye & Ear, Boston, MA 02114 USA
[3] Minist Educ Brazil, CAPES Fdn, Brasilia, DF, Brazil
[4] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2020年 / 9卷 / 12期
关键词
Boston Keratoprosthesis; optics; artificial cornea; TITANIUM; MULTICENTER; METALENSES; GLAUCOMA; OUTCOMES; SURGERY; EYE;
D O I
10.1167/tvst.9.12.10
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To benchmark the optical performance of Boston Keratoprosthesis (B-KPro). Methods: Back focal lengths (BFL) of B-KPros for various eye axial lengths were measured using an optical bench, International Organization for Standardization-certified for intraocular lens characterization, and compared against manufacturer's specification. The modulation transfer function (MTF) and the resolution efficiencies were measured. The theoretical geometry-dependent higher-order aberrations (HOA) were calculated. The devices were characterized with optical profilometry for estimating the surface scattering. Aberration correction and subsequent image quality improvement were simulated in CODE-V. Natural scene-imaging was performed in a mock ocular environment. Retrospective analysis of 15 B-KPro recipient eyes were presented to evaluate the possibility of achieving 20/20 best-corrected visual acuity (BCVA). Results: BFL measurements were in excellent agreement with the manufacturer-reported values (r = 0.999). The MTF specification exceeded what is required for achieving 20/20 visual acuity. Astigmatism and field curvature, correctable in simulations, were the primary aberrations limiting imaging performance. Profilonnetry of the anterior surface revealed nanoscale roughness (root-mean-square amplitude, 30-50 nm), contributing negligibly to optical scattering. Images of natural scenes obtained with a simulated B-KPro eye demonstrated good central vision, with 10/10 visual acuity (equivalent to 20/20). Full restoration of 20/20 BCVA was obtainable for over 9 years in some patients. Conclusions: Theoretical and experimental considerations demonstrate that B-KPro has the optical capacity to restore 20/20 BCVA in patients. Further image quality improvement can be anticipated through correction of HOAs. Translational Relevance: We establish an objective benchmark to characterize the optics of the B-KPro and other keratoprosthesis and propose design changes to allow improved vision in B-KPro patients.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [21] Type 1 Boston keratoprosthesis: outcomes at two Canadian centres
    Noel, Christopher W.
    Isenberg, Jordan
    Goldich, Yakov
    Conlon, Ronan
    Teichman, Joshua
    Rubinger, Daniel A.
    Weinberg, Tessa A. I.
    Slomovic, Jaclyn
    Chan, Clara C.
    Rootman, David S.
    Baig, Kashif M.
    Slomovic, Allan R.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2016, 51 (02): : 76 - 82
  • [22] Outcomes of bilateral sequential implantation of the Boston keratoprosthesis type 1
    Vaillancourt, Louis
    Papanagnu, Eleni
    Elfekhfakh, Marwan
    Fadous, Raphaelle
    Harissi-Dagher, Mona
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2017, 52 (01): : 80 - 84
  • [23] The Boston Keratoprosthesis type 1 as primary penetrating corneal procedure
    Fadous, Raphaelle
    Levallois-Gignac, Samuel
    Vaillancourt, Louis
    Robert, Marie-Claude
    Harissi-Dagher, Mona
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (12) : 1664 - 1668
  • [24] Challenges in management of the Boston Keratoprosthesis Type 1
    Koo, Ellen H.
    Hannush, Sadeer B.
    CURRENT OPINION IN OPHTHALMOLOGY, 2021, 32 (04) : 385 - 388
  • [25] Long-Term Results of the Boston Keratoprosthesis for Unilateral Corneal Disease
    Kosker, Mustafa
    Suri, Kunal
    Rapuano, Christopher J.
    Ayres, Brandon D.
    Nagra, Parveen K.
    Raber, Irving M.
    Hammersmith, Kristin M.
    CORNEA, 2015, 34 (09) : 1057 - 1062
  • [26] Treatment of Aniridia With Boston Type I Keratoprosthesis
    Rixen, Jordan J.
    Cohen, Alex W.
    Kitzmann, Anna S.
    Wagoner, Michael D.
    Goins, Kenneth M.
    CORNEA, 2013, 32 (07) : 947 - 950
  • [27] Advantages of microscope-integrated intraoperative online optical coherence tomography: usage in Boston keratoprosthesis type I surgery
    Siebelmann, Sebastian
    Steven, Philipp
    Hos, Deniz
    Huettmann, Gereon
    Lankenau, Eva
    Bachmann, Bjoern
    Cursiefen, Claus
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (01)
  • [28] Introduction to the use of the Boston keratoprosthesis
    Dohlman, Claes H.
    Harissi-Dagher, Mona
    Khan, Bilal F.
    Sippel, Kimberly
    Aquavella, James V.
    Graney, John M.
    EXPERT REVIEW OF OPHTHALMOLOGY, 2006, 1 (01) : 41 - 48
  • [29] The Role of the Back Plate in Angle Anatomy with the Boston Type I Keratoprosthesis
    Taniguchi, Elise V.
    Paschalis, Eleftherios I.
    Crnej, Alja
    Ren, Ai
    Colby, Kathryn A.
    Chodosh, James
    Pasquale, Louis R.
    Shen, Lucy Q.
    Dohlman, Claes H.
    Cruzat, Andrea
    CORNEA, 2017, 36 (09) : 1096 - 1101
  • [30] Boston type I keratoprosthesis. Review
    Magalhaes, Fernanda Pedreira
    de Sousa, Luciene Barbosa
    De Oliveira, Lauro Augusto
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2012, 75 (03) : 218 - 222