Intrinsic Optical Properties of Boston Keratoprosthesis

被引:2
|
作者
Hui, Pui-Chuen [1 ,2 ]
Pereira, Leonardo A. [1 ,3 ]
Dore, Renald [4 ]
Chen, Shengtong [4 ]
Taniguchi, Elise [1 ,2 ]
Chodosh, James [1 ]
Dohlman, Claes H. [1 ,2 ]
Paschalis, Eleftherios, I [1 ,2 ]
机构
[1] Harvard Med Sch, Dept Ophthalmol, Massachusetts Eye & Ear, Boston, MA 02114 USA
[2] Harvard Med Sch, Schepens Eye Res Inst, Boston Keratoprosthesis Lab, Massachusetts Eye & Ear, Boston, MA 02114 USA
[3] Minist Educ Brazil, CAPES Fdn, Brasilia, DF, Brazil
[4] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2020年 / 9卷 / 12期
关键词
Boston Keratoprosthesis; optics; artificial cornea; TITANIUM; MULTICENTER; METALENSES; GLAUCOMA; OUTCOMES; SURGERY; EYE;
D O I
10.1167/tvst.9.12.10
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To benchmark the optical performance of Boston Keratoprosthesis (B-KPro). Methods: Back focal lengths (BFL) of B-KPros for various eye axial lengths were measured using an optical bench, International Organization for Standardization-certified for intraocular lens characterization, and compared against manufacturer's specification. The modulation transfer function (MTF) and the resolution efficiencies were measured. The theoretical geometry-dependent higher-order aberrations (HOA) were calculated. The devices were characterized with optical profilometry for estimating the surface scattering. Aberration correction and subsequent image quality improvement were simulated in CODE-V. Natural scene-imaging was performed in a mock ocular environment. Retrospective analysis of 15 B-KPro recipient eyes were presented to evaluate the possibility of achieving 20/20 best-corrected visual acuity (BCVA). Results: BFL measurements were in excellent agreement with the manufacturer-reported values (r = 0.999). The MTF specification exceeded what is required for achieving 20/20 visual acuity. Astigmatism and field curvature, correctable in simulations, were the primary aberrations limiting imaging performance. Profilonnetry of the anterior surface revealed nanoscale roughness (root-mean-square amplitude, 30-50 nm), contributing negligibly to optical scattering. Images of natural scenes obtained with a simulated B-KPro eye demonstrated good central vision, with 10/10 visual acuity (equivalent to 20/20). Full restoration of 20/20 BCVA was obtainable for over 9 years in some patients. Conclusions: Theoretical and experimental considerations demonstrate that B-KPro has the optical capacity to restore 20/20 BCVA in patients. Further image quality improvement can be anticipated through correction of HOAs. Translational Relevance: We establish an objective benchmark to characterize the optics of the B-KPro and other keratoprosthesis and propose design changes to allow improved vision in B-KPro patients.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [1] Expanding indications for the Boston keratoprosthesis
    Colby, Kathryn A.
    Koo, Euna B.
    CURRENT OPINION IN OPHTHALMOLOGY, 2011, 22 (04) : 267 - 273
  • [2] Boston Keratoprosthesis Type 1 in Chemical Burns
    Salvador-Culla, Borja
    Kolovou, Paraskevi E.
    Arzeno, Linnette
    Martinez, Santiago
    Lopez, Miguel A.
    CORNEA, 2016, 35 (06) : 911 - 916
  • [3] The Boston keratoprosthesis
    Saeed, Hajirah N.
    Shanbhag, Swapna
    Chodosh, James
    CURRENT OPINION IN OPHTHALMOLOGY, 2017, 28 (04) : 390 - 396
  • [4] Infectious endophthalmitis in Boston keratoprosthesis: incidence and prevention
    Behlau, Irmgard
    Martin, Kathryn V.
    Martin, Jacqueline N.
    Naumova, Elena N.
    Cadorette, James J.
    Sforza, J. Tammy
    Pineda, Roberto, II
    Dohlman, Claes H.
    ACTA OPHTHALMOLOGICA, 2014, 92 (07) : e546 - e555
  • [5] Titanium Coating of the Boston Keratoprosthesis
    Salvador-Culla, Borja
    Jeong, Kyung Jae
    Kolovou, Paraskevi Evi
    Chiang, Homer H.
    Chodosh, James
    Dohlman, Claes H.
    Kohane, Daniel S.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2016, 5 (02):
  • [6] Results with the Boston keratoprosthesis
    Koller, B.
    Neuhann, T.
    Neuhann, I.
    OPHTHALMOLOGE, 2012, 109 (05): : 454 - 461
  • [7] Challenges of Glaucoma Management in Patients with Type I Boston Keratoprosthesis
    AlHilali, Sara M.
    Al-Swailem, Samar A.
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 369 - 374
  • [8] Boston type 1 keratoprosthesis: the New York Eye and Ear experience
    Patel, A. P.
    Wu, E. I.
    Ritterband, D. C.
    Seedor, J. A.
    EYE, 2012, 26 (03) : 418 - 425
  • [9] Management of glaucoma with Boston type 1 keratoprosthesis
    Utine, Canan Asli
    Arikan, Gul
    Yardim, Elvan
    Gunenc, Uzeyir
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2023, 86 (02) : 137 - 144
  • [10] Boston Keratoprosthesis
    Kwitko, Sergio
    Stolz, Andressa Prestes
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2012, 71 (06) : 403 - 406