A flexible micro fluid transport system featuring magnetorheological elastomer

被引:38
作者
Behrooz, Majid [1 ]
Gordaninejad, Faramarz [1 ]
机构
[1] Univ Nevada, Dept Mech Engn, Composite & Intelligent Mat Lab, Reno, NV 89557 USA
关键词
magnetorheological elastomer; fluid transport system; magneto-fluid-structure interaction; ARTIFICIAL BLOOD-VESSEL; MODEL; DESIGN; MEMBRANE;
D O I
10.1088/0964-1726/25/2/025011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This study presents a flexible magnetically-actuated micro fluid transport system utilizing an isotropic magnetorheological elastomer (MRE). Theoretical modeling and analysis of this system is presented for a two-dimensional model. This fluid transport system can propel the fluid by applying a fluctuating magnetic field on the MRE. The magneto-fluid-structure interaction analysis is employed to determine movement of the solid domain and the velocity of the fluid under a controllable magnetic field. The effects of key material, geometric, and magnetic parameters on the behavior of this system are examined. It is demonstrated that the proposed system can propel the fluid unidirectionally, and the volume of the transported fluid is significantly affected by some of the design parameters.
引用
收藏
页数:11
相关论文
共 50 条
[21]  
Hron J., 2006, Lecture notes in computational science and engineering, Fluid-structure interaction: modeling, simulation, optimization, P146, DOI DOI 10.1007/3-540-34596-5_
[22]   A monolithic approach to fluid-structure interaction using space-time finite elements [J].
Hübner, B ;
Walhorn, E ;
Dinkler, D .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2004, 193 (23-26) :2087-2104
[23]   Experimental investigation of the flow induced by artificial cilia [J].
Hussong, J. ;
Schorr, N. ;
Belardi, J. ;
Prucker, O. ;
Ruehe, J. ;
Westerweel, J. .
LAB ON A CHIP, 2011, 11 (12) :2017-2022
[24]   Recent advances in microscale pumping technologies: a review and evaluation [J].
Iverson, Brian D. ;
Garimella, Suresh V. .
MICROFLUIDICS AND NANOFLUIDICS, 2008, 5 (02) :145-174
[25]   Parameter sensitivity analysis of a lumped-parameter model of a chain of lymphangions in series [J].
Jamalian, Samira ;
Bertram, Christopher D. ;
Richardson, William J. ;
Moore, James E., Jr. .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2013, 305 (12) :H1709-H1717
[26]   CONSTRUCTION OF AN ARTIFICIAL BLOOD-VESSEL WALL FROM CULTURED ENDOTHELIAL AND SMOOTH-MUSCLE CELLS [J].
JONES, PA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1979, 76 (04) :1882-1886
[27]   Artificial blood vessel: The Holy Grail of peripheral vascular surgery [J].
Kakisis, JD ;
Liapis, CD ;
Breuer, C ;
Sumpio, BE .
JOURNAL OF VASCULAR SURGERY, 2005, 41 (02) :349-354
[28]   Magnetically-actuated artificial cilia for microfluidic propulsion [J].
Khaderi, S. N. ;
Craus, C. B. ;
Hussong, J. ;
Schorr, N. ;
Belardi, J. ;
Westerweel, J. ;
Prucker, O. ;
Ruehe, J. ;
den Toonder, J. M. J. ;
Onck, P. R. .
LAB ON A CHIP, 2011, 11 (12) :2002-2010
[29]   Micro magnetic silicone elastomer membrane actuator [J].
Khoo, M ;
Liu, C .
SENSORS AND ACTUATORS A-PHYSICAL, 2001, 89 (03) :259-266
[30]  
Kim D-J, 2011, Implantable tube and coating method thereof US Patent Specification No, Patent No. [US 20110178592, 20110178592]