Transapical off-pump mitral valve repair with NeoChord implantation: A systematic review

被引:9
作者
Ahmed, Ahmed [1 ]
Abdel-Aziz, Tarek A. [2 ]
AlAsaad, Mohannad M. R. [2 ]
Majthoob, Motaz [2 ]
机构
[1] Ain Shams Univ, Fac Med, Dept Cardiothorac Surg, Cairo 11517, Egypt
[2] Dubai Hosp, Dept Cardiothorac Surg, Dubai, U Arab Emirates
关键词
mitral regurgitation; mitral valve repair; NeoChord DS1000; ANESTHETIC MANAGEMENT; ARTIFICIAL CHORDAE; REGURGITATION; OUTCOMES; DISEASE;
D O I
10.1111/jocs.15350
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Mitral valve repair (MVr) is the gold standard for the treatment of degenerative mitral valve regurgitation (MR). The recently introduced NeoChord DS1000 has gained increasing recognition as a feasible, potentially safe, and effective procedure with minor complications and promising outcomes. This study aims to conduct a systematic review of the published literature that discusses the technical feasibility and outcome of transapical off-pump MVr with NeoChord DS1000 device implantation in the treatment of degenerative MR. Methods: This review was performed according to the PRISMA statement. Databases searched in this review included Pubmed, Web of Science, Scopus, and Cochrane databases for systematic reviews. All English articles on humans reporting isolated MVr using NeoChord DS1000 device were included provided that basic preoperative data, operative specifications, and postoperative mortality and morbidity were reported. Results: This review included six studies comprised 249 patients who had NeoChord mitral procedure. Almost all patients included had severe MR (243/249, 97.6%). Operative success was achieved in 241 out of the 249 patients (96.8%). No intraoperative mortality was reported. Intraoperative arrhythmia was reported in six patients (2.4%) and significant bleeding was reported in eight patients (3.2%). Conclusion: Awaiting more evidence, NeoChord mitral procedure appears to be a promising procedure that can be considered in selected cases.
引用
收藏
页码:1492 / 1498
页数:7
相关论文
共 50 条
  • [31] Off-Pump Transapical Implantation of Artificial Neo-Chordae to Correct Mitral Regurgitation
    Seeburger, Joerg
    Rinaldi, Mauro
    Nielsen, Sten Lyager
    Salizzoni, Stefano
    Lange, Ruediger
    Schoenburg, Markus
    Alfieri, Ottavio
    Borger, Michael Andrew
    Mohr, Friedrich Wilhelm
    Aidietis, Audrius
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (09) : 914 - 919
  • [32] Feasibility of Anterior Mitral Leaflet Flail Repair With Transapical Beating-Heart Neochord Implantation
    Colli, Andrea
    Manzan, Erica
    Zucchetta, Fabio
    Sarais, Cristiano
    Pittarello, Demetrio
    Gerosa, Gino
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (11) : 1320 - 1321
  • [33] Microinvasive mitral valve repair with transapical mitral neochordae implantation
    Bergonzoni, Emma
    D'Onofrio, Augusto
    Mastro, Florinda
    Gerosa, Gino
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [34] Off-pump mitral valve repair: is less really more? Reply
    Colli, Andrea
    Bizzotto, Eleonora
    Besola, Laura
    Gerosa, Gino
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (06) : 1148 - 1148
  • [35] Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair
    Chan, Daniel Tai-Leung
    Bhatia, Inderjeet
    Lam, Simon Chi-Cheung
    Au, Timmy Wing-Kuk
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (01) : 57 - 64
  • [36] Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair
    Daniel Tai-Leung Chan
    Inderjeet Bhatia
    Simon Chi-Cheung Lam
    Timmy Wing-Kuk Au
    Journal of Artificial Organs, 2024, 27 : 57 - 64
  • [37] Mitral valve repair facilitated with transapical beating heart NeoChord implantation in a non-Hodgkin’s lymphoma patient
    Ali Sait Kavakli
    Raif Umut Ayoglu
    Nilgun Kavrut Ozturk
    Omer Haldun Tekinalp
    Zehra Erkal
    Kerem Inanoglu
    Mustafa Emmiler
    Journal of Anesthesia, 2016, 30 : 1056 - 1059
  • [38] New Self-Expanding Transcatheter Valve for Off-Pump Transatrial Mitral Valve-In-Ring Implantation
    Ma, Liang
    Yu, Zipu
    Huber, Christoph
    Li, Chengchen
    Qian, Linfeng
    Jiang, Jianjie
    Zou, Yu
    CARDIOLOGY, 2015, 132 (04) : 221 - 227
  • [39] Off pump mitral valve repair
    Kestutis Rucinskas
    Vilius Janusauskas
    Diana Zakarkaite
    Rita Kramena
    Gabija Janaviciute
    Agne Drasutiene
    Robertas Stasys Samalavicius
    Audrius Aidietis
    Journal of Cardiothoracic Surgery, 10 (Suppl 1)
  • [40] Transapical beating heart mitral valve repair with the NeoChord system: early outcomes of a single-center experience
    Wrobel, Krzysztof
    Kurnicka, Katarzyna
    Zygier, Marcin
    Zielinski, Dariusz
    Dyk, Wojciech
    Wojdyga, Ryszard
    Juraszynski, Zbigniew
    Pruszczyk, Piotr
    Biederman, Andrzej
    VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2019, 14 (02) : 320 - 325