Field demonstration of a first constant-temperature thermal response test with both heat injection and extraction for ground source heat pump systems

被引:22
作者
Jia, Jie [1 ]
Lee, W. L. [2 ]
Cheng, Yuanda [1 ]
机构
[1] Taiyuan Univ Technol, Dept Built Environm & Energy Utilizat Engn, Taiyuan, Shanxi, Peoples R China
[2] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Borehole heat exchanger; Field demonstration; Ground source heat pump; Ground thermal conductivity; Heat transfer; Thermal response test; LINE-SOURCE MODEL; PARAMETER-ESTIMATION; BAYESIAN-INFERENCE; EXCHANGERS; RESISTANCE; ERROR;
D O I
10.1016/j.apenergy.2019.04.145
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Getting an accurate estimate of site-specific ground thermal conductivity from thermal response tests (TRTs) is crucial to the efficient and sustainable use of ground source heat pump systems. In a conventional TRT, the ground thermal conductivity is estimated by perturbing the ground with a positive heat injection and the response is measured in time. Despite the simplicity, the conventional TRT does not take into account the ground thermal response to cooling pulses. This may lead to mode-biased estimation due to the presence of natural convective effect. To address the problem, a constant-temperature TRT that comprises simultaneous heat injection and extraction was proposed. A test data analysis method was developed based on the finite line-source model. On this basis, a very first field test was performed in Taiyuan, China, demonstrating the use of the proposed TRT concept with full-scale measurements. Results show that, in the case of this field test, the ground thermal conductivities derived separately from heat injection and heat extraction are 1.83 W/(m K) and 1.65 W/(m K), respectively. The significant difference (10.9%) indicates that when heat injection is involved, the natural convective effect has enhanced ground heat transfer to increase the conductivity estimate. Thus, as compared to the conventional approach, the use of the proposed TRT can improve the characterization of the ground thermal response and conductivity. Relevant results and the test protocol reported in this study will be useful in providing the background information for this technology to be adopted in the ground source heat pump industry.
引用
收藏
页码:79 / 86
页数:8
相关论文
共 50 条
  • [31] Demonstration study on ground source heat pump heating system with solar thermal energy storage for greenhouse heating
    Yang, Xufei
    Sun, Dongliang
    Li, Jingfa
    Yu, Changyong
    Deng, Yajun
    Yu, Bo
    JOURNAL OF ENERGY STORAGE, 2022, 54
  • [32] Feasibility of combined solar thermal and ground source heat pump systems in cold climate, Canada
    Rad, Farzin M.
    Fung, Alan S.
    Leong, Wey H.
    ENERGY AND BUILDINGS, 2013, 61 : 224 - 232
  • [33] Effect of vertical ground temperature distribution on parameter estimation of in-situ thermal response test with unstable heat rate
    Zhang, Changxing
    Song, Wei
    Liu, Yufeng
    Kong, Xiangqiang
    Wang, Qing
    RENEWABLE ENERGY, 2019, 136 : 264 - 274
  • [34] The Application of Ground Source Heat Pump to Indoor Constant Temperature Swimming Pool Water Heating in the Subtropical Region
    Hu, Yingning
    Liu, Tao
    Hu, Shanshan
    Lin, Jun
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT, PTS 1-3, 2012, 209-211 : 1727 - 1734
  • [35] Field test of a ground-source heat pump system and numerical investigation on advanced control strategies
    Li, Yiming
    Qian, Suxin
    APPLIED THERMAL ENGINEERING, 2024, 246
  • [36] The Effect of Groundwater Flow on the Thermal Performance of a Novel Borehole Heat Exchanger for Ground Source Heat Pump Systems: Small Scale Experiments and Numerical Simulation
    Serageldin, Ahmed A.
    Radwan, Ali
    Sakata, Yoshitaka
    Katsura, Takao
    Nagano, Katsunori
    ENERGIES, 2020, 13 (06)
  • [37] NUMERICAL SIMULATION OF GROUND TEMPERATURE FIELD CHANGE IN UNDERGROUND HEAT TRANSFER ZONE OF GROUND SOURCE HEAT PUMP UNDER DIFFERENT GROUNDWATER RUNOFF CONDITIONS
    Chen, Dongqin
    THERMAL SCIENCE, 2024, 28 (2B): : 1245 - 1251
  • [38] Recent research and applications of ground source heat pump integrated with thermal energy storage systems: A review
    Zhu, Na
    Hu, Pingfang
    Xu, Linghong
    Jiang, Zhangning
    Lei, Fei
    APPLIED THERMAL ENGINEERING, 2014, 71 (01) : 142 - 151
  • [39] Thermal and economic performance of horizontal ground source heat pump systems with different flowrate control methods
    Zhou, Kun
    Mao, Jinfeng
    Li, Yong
    Zhang, Hua
    Chen, Shangyuan
    Chen, Fei
    JOURNAL OF BUILDING ENGINEERING, 2022, 53
  • [40] Zoning operation of energy piles to alleviate the soil thermal imbalance of ground source heat pump systems
    You T.
    Zeng W.
    Energy and Built Environment, 2023, 4 (01): : 57 - 63