Field demonstration of a first constant-temperature thermal response test with both heat injection and extraction for ground source heat pump systems

被引:22
|
作者
Jia, Jie [1 ]
Lee, W. L. [2 ]
Cheng, Yuanda [1 ]
机构
[1] Taiyuan Univ Technol, Dept Built Environm & Energy Utilizat Engn, Taiyuan, Shanxi, Peoples R China
[2] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Borehole heat exchanger; Field demonstration; Ground source heat pump; Ground thermal conductivity; Heat transfer; Thermal response test; LINE-SOURCE MODEL; PARAMETER-ESTIMATION; BAYESIAN-INFERENCE; EXCHANGERS; RESISTANCE; ERROR;
D O I
10.1016/j.apenergy.2019.04.145
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Getting an accurate estimate of site-specific ground thermal conductivity from thermal response tests (TRTs) is crucial to the efficient and sustainable use of ground source heat pump systems. In a conventional TRT, the ground thermal conductivity is estimated by perturbing the ground with a positive heat injection and the response is measured in time. Despite the simplicity, the conventional TRT does not take into account the ground thermal response to cooling pulses. This may lead to mode-biased estimation due to the presence of natural convective effect. To address the problem, a constant-temperature TRT that comprises simultaneous heat injection and extraction was proposed. A test data analysis method was developed based on the finite line-source model. On this basis, a very first field test was performed in Taiyuan, China, demonstrating the use of the proposed TRT concept with full-scale measurements. Results show that, in the case of this field test, the ground thermal conductivities derived separately from heat injection and heat extraction are 1.83 W/(m K) and 1.65 W/(m K), respectively. The significant difference (10.9%) indicates that when heat injection is involved, the natural convective effect has enhanced ground heat transfer to increase the conductivity estimate. Thus, as compared to the conventional approach, the use of the proposed TRT can improve the characterization of the ground thermal response and conductivity. Relevant results and the test protocol reported in this study will be useful in providing the background information for this technology to be adopted in the ground source heat pump industry.
引用
收藏
页码:79 / 86
页数:8
相关论文
共 50 条
  • [1] Constant-temperature thermal response test (TRT) with both heat injection and extraction for ground source heat pump systems: Methodology and a case study
    Jia, Jie
    Lee, W. L.
    Cheng, Yuanda
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 797 - 802
  • [2] Thermal response test for ground source heat pump based on constant temperature and heat-flux methods
    Yu, Xiaohui
    Zhang, Yufeng
    Deng, Na
    Ma, Hongting
    Dong, Shengming
    APPLIED THERMAL ENGINEERING, 2016, 93 : 678 - 682
  • [3] IN-SITU THERMAL RESPONSE TEST FOR GROUND SOURCE HEAT PUMP APPLICATION
    Cui, Wenzhi
    Liao, Quan
    Chang, Guiqin
    Peng, Qingyuan
    Jen, Tien-Chien
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 4, PTS A AND B, 2012, : 677 - 683
  • [4] Thermal response testing for ground source heat pump systems-An historical review
    Spitler, Jeffrey D.
    Gehlin, Signhild E. A.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 50 : 1125 - 1137
  • [5] Improved method and case study of thermal response test for borehole heat exchangers of ground source heat pump system
    Wang, Huajun
    Qi, Chengying
    Du, Hongpu
    Gu, Jihao
    RENEWABLE ENERGY, 2010, 35 (03) : 727 - 733
  • [6] Field demonstration of a first thermal response test with a low power source
    Raymond, Jasmin
    Lamarche, Louis
    Malo, Michel
    APPLIED ENERGY, 2015, 147 : 30 - 39
  • [7] In-situ thermal response test for ground source heat pump system in Elazig, Turkey
    Esen, Hikmet
    Inalli, Mustafa
    ENERGY AND BUILDINGS, 2009, 41 (04) : 395 - 401
  • [8] Effects of multiple ground layers on thermal response test analysis and ground-source heat pump simulation
    Lee, C. K.
    APPLIED ENERGY, 2011, 88 (12) : 4405 - 4410
  • [9] A review on thermal response test of ground-coupled heat pump systems
    Zhang, Changxing
    Guo, Zhanjun
    Liu, Yufeng
    Cong, Xiaochun
    Peng, Donggen
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 40 : 851 - 867
  • [10] Analysis of group bore thermal response test of ground source heat pump project
    Zheng Y.
    Duan X.
    Lin Q.
    Li S.
    Zhou S.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (09): : 422 - 427