Validating Left Atrial Low Voltage Areas During Atrial Fibrillation and Atrial Flutter Using Multielectrode Automated Electroanatomic Mapping

被引:80
作者
Rodriguez-Manero, Moises [1 ,2 ]
Valderrabano, Miguel [3 ]
Baluja, Aurora [4 ]
Kreidieh, Omar [5 ]
Martinez-Sande, Jose Luis [1 ,2 ]
Garcia-Seara, Javier [1 ,2 ]
Saenen, Johan [6 ]
Iglesias-Alvarez, Diego [1 ,2 ]
Bories, Wim [6 ]
Miguel Villamayor-Blanco, Luis [1 ]
Pereira-Vazquez, Maria [1 ]
Lage, Ricardo [1 ,2 ]
Alvarez-Escudero, Julian [4 ]
Heidbuchel, Hein [6 ]
Ramon Gonzalez-Juanatey, Jose [1 ,2 ]
Sarkozy, Andrea [6 ]
机构
[1] Hosp Univ Santiago Compostela, Cardiol Dept, IDIS, Santiago De Compostela, Spain
[2] Ctr Invest Biomed Red Enfermedades Cardiovasc, CIBERCV CB16 11 00226 CB16 11 00420, Madrid, Spain
[3] Houston Methodist Hosp, Div Cardiac Electrophysiol, Dept Cardiol, Houston, TX USA
[4] Hosp Clin Univ, Dept Anesthesiol Intens Care & Pain Management, Crit Patient Translat Res Grp, Santiago De Compostela, Spain
[5] Newark Beth Israel Med Ctr, Cardiol Dept, Newark, NJ USA
[6] Univ Hosp Antwerp, Cardiac Electrophysiol Sect, Cardiol Dept, Antwerp, Belgium
关键词
atrial fibrillation; high-density mapping; low voltage; CATHETER ABLATION; FRACTIONATED ELECTROGRAMS; SINUS RHYTHM; SUBSTRATE; SCAR; ENHANCEMENT; ARRHYTHMIAS; SUCCESS; WALL;
D O I
10.1016/j.jacep.2018.08.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study aimed: 1) to determine the voltage correlation between sinus rhythm (SR) and atrial fibrillation (AF)/atrial flutter (AFL) using multielectrode fast automated mapping; 2) to identify a bipolar voltage cutoff for scar and/or low voltage areas (LVAs); and 3) to examine the reproducibility of voltage mapping in AF. BACKGROUND It is unclear if bipolar voltage cutoffs should be adjusted depending on the rhythm and/or area being mapped. METHODS High-density mapping was performed first in SR and afterward in induced AF/AFL. In some patients, 2 maps were performed during AF. Maps were combined to create a new one. Points of <1 mm difference were analyzed. Correlation was explored with scatterplots and agreement analysis was assessed with Bland-Altman plots. The generalized additive model was also applied. RESULTS A total of 2,002 paired-points were obtained. A cutoff of 0.35 mV in AFL predicted a sinus voltage of 0.5 mV (95% confidence interval [CI]: 0.12 to 2.02) and of 0.24 mV in AF (95% CI: 0.11 to 2.18; specificity [SP]: 0.94 and 0.96; sensitivity [SE]: 0.85 and 0.75, respectively). When generalized additive models were used, a cutoff of 0.38 mV was used for AFL for predicting a minimum value of 0.5 mV in SR (95% CI: 0.5 to 1.6; SP: 0.94, SE: 0.88) and of 0.31 mV for AF (95% CI: 0.5 to 1.2; SP: 0.95, SE: 0.82). With regard to AF maps, there was no change in the classification of any left atrial region other than the roof. CONCLUSIONS It is possible to establish new cutoffs for AFL and/or AF with acceptable validity in predicting a sinus voltage of <0.5 mV. Multielectrode fast automated mapping in AFL and/or AF seems to be reliable and reproducible when classifying LVAs. These observations have clinical implications for left atrial voltage distribution and in procedures in which scar distribution is used to guide pulmonary vein isolation and/or re-isolation. (C) 2018 by the American College of Cardiology Foundation.
引用
收藏
页码:1541 / 1552
页数:12
相关论文
共 34 条
[1]   Evaluation of a novel high-resolution mapping technology for ablation of recurrent scar-related atrial tachycardias [J].
Anter, Elad ;
McElderry, Thomas H. ;
Contreras-Valdes, Fernando M. ;
Li, Jianqing ;
Tung, Patricia ;
Leshem, Eran ;
Haffajee, Charles I. ;
Nakagawa, Hiroshi ;
Josephson, Mark E. .
HEART RHYTHM, 2016, 13 (10) :2048-2055
[2]   Bipolar voltage amplitude: What does it really mean? [J].
Anter, Elad ;
Josephson, Mark E. .
HEART RHYTHM, 2016, 13 (01) :326-327
[3]   High-Resolution Mapping of Scar-Related Atrial Arrhythmias Using Smaller Electrodes With Closer Interelectrode Spacing [J].
Anter, Elad ;
Tschabrunn, Cory M. ;
Josephson, Mark E. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (03) :537-545
[4]   Arrhythmogenic Atrial Substrate in Persistent Atrial Fibrillation Relationship to Heart Failure [J].
Arentz, Thomas ;
Mueller-Edenborn, Bjoern ;
Jadidi, Amir .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (01) :97-98
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Left Atrial Substrate Modification Targeting Low-Voltage Areas for Catheter Ablation of Atrial Fibrillation: A Systematic Review and Meta-Analysis [J].
Blandino, Alessandro ;
Bianchi, Francesca ;
Grossi, Stefano ;
Biondi-Zoccai, Giuseppe ;
Conte, Maria Rosa ;
Gaido, Luca ;
Gaita, Fiorenzo ;
Scaglione, Marco ;
Rametta, Francesco .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (02) :199-212
[7]   Impact of Voltage Mapping to Guide Whether to Perform Ablation of the Posterior Wall in Patients With Persistent Atrial Fibrillation [J].
Cutler, Michael J. ;
Johnson, Jeremy ;
Abozguia, Khalid ;
Rowan, Shane ;
Lewis, William ;
Costantini, Otto ;
Natale, Andrea ;
Ziv, Ohad .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (01) :13-21
[8]   A practical approach to Bland-Altman plots and variation coefficients for log transformed variables [J].
Euser, Anne M. ;
Dekker, Friedo W. ;
le Cessie, Saskia .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2008, 61 (10) :978-982
[9]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[10]   Characterization of Fractionated Atrial Electrograms Critical for Maintenance of Atrial Fibrillation A Randomized, Controlled Trial of Ablation Strategies (The CFAE AF Trial) [J].
Hunter, Ross J. ;
Diab, Ihab ;
Tayebjee, Muzahir ;
Richmond, Laura ;
Sporton, Simon ;
Earley, Mark J. ;
Schilling, Richard J. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (05) :622-629