Experimental and Numerical Investigation of the Performance of Piles and Suction Caissons Subjected to Inclined Cyclic Loading in Cohesive Soils

被引:19
作者
Al-Janabi, Husham A. [1 ]
Aubeny, Charles P. [2 ]
机构
[1] Minist Oil Oil Complex Bldg, State Co Oil Projects SCOP, Port Said St,POB 198, Baghdad, Iraq
[2] Texas A&M Univ, Dept Civil & Environm Engn, College Stn, TX 77843 USA
基金
美国国家科学基金会;
关键词
Caisson; Inclined cyclic loading; Cumulative deformations; Storms (nonuniform load amplitudes); Offshore structure; Experimental and numerical study; CAPACITY; TESTS;
D O I
10.1061/(ASCE)GT.1943-5606.0002789
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Cyclic loading on caisson and pile anchors can be a significant design issue, particularly with respect to cumulative vertical displacements that can lead to reduction in embedment depth and load capacity of the anchor. Most existing design methodologies are based on monotonic load capacity, often accounting for potential soil strength degradation due to cyclic loading. Because the cyclic strength criterion is often based on cumulative strains, these approaches arguably implicitly consider cumulative deformations. However, cumulative plastic deformations under storm conditions should be investigated. Piles and caissons serving as anchors for floating offshore structures experience inclined cyclic loading. This paper presents (1) monotonic and cyclic loading tests in the vertical and lateral directions, and (2) a finite-element (FE) investigation of different aspect ratios (L/D = 4, 5, and 6) of caissons subjected to different load angles (psi = 0 degrees to 45 degrees from the horizontal). Additionally, it presents a precise method to calibrate the constitutive model (nonlinear kinematic hardening model), where the calibrated model was match to monotonic and cyclic lateral and vertical loading tests. Nonuniform load amplitudes were used in the FE investigation. The primary finding from the investigation was that the influence of the cumulative displacements increases when increasing the load amplitudes, especially for the load inclinations of 0 degrees-20 degrees for the lateral displacements and 20 degrees-45 degrees for the vertical displacements. (C) 2022 American Society of Civil Engineers.
引用
收藏
页数:12
相关论文
共 28 条
[11]  
Aubeny CP, 2001, INT J OFFSHORE POLAR, V11, P211
[12]   Inclined load capacity of suction caissons [J].
Aubeny, CP ;
Han, SW ;
Murff, JD .
INTERNATIONAL JOURNAL FOR NUMERICAL AND ANALYTICAL METHODS IN GEOMECHANICS, 2003, 27 (14) :1235-1254
[13]  
Colliat J.L., 1997, P 7 INT C BEH OFFSH, V1, P133
[14]  
DeJong J, 2010, GEOTECH TEST J, V33, P137
[15]   Experimental study on the behavior of strip footing on sandy soil bounded by a wall [J].
Fattah, Mohammed Y. ;
Shlash, Kais T. ;
Mohammed, Husham A. .
ARABIAN JOURNAL OF GEOSCIENCES, 2015, 8 (07) :4779-4790
[16]   Bearing Capacity of Rectangular Footing on Sandy Soil Bounded by a Wall [J].
Fattah, Mohammed Y. ;
Shlash, Kais T. ;
Mohammed, Husham A. .
ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2014, 39 (11) :7621-7633
[17]  
Fattah MY., 2014, Engineering and Technology Journal, V32, P1083, DOI [10.30684/etj.32.5A.1, DOI 10.30684/ETJ.32.5A.1]
[18]  
Gerolymos N., 2005, Proc. 1st Greece-Japan Worksho: Seismic Design, Observation, and retrofit of Foundation, P25
[19]  
Gilbert R.B., 2015, Design of wind turbine monpiles for lateral loads
[20]  
Jardine R.J., 1992, SOILS FOUND, V32, P111, DOI [10.3208/sandf1972.32.2_111, DOI 10.3208/SANDF1972.32.2_111]