Validation of a Standard Operating Procedure (SOP) for Forensic Soils Investigation in Brazil

被引:7
|
作者
Testoni, Samara Alves [1 ]
Melo, Vander Freitas [1 ]
Dawson, Lorna Anne [2 ]
da Silva Salvador, Fabio Augusto [3 ]
Kunii, Paulo Akira [3 ]
机构
[1] Univ Fed Parana, Dept Solos & Engn Agr, Programa Posgrad Ciencia Solo, Curitiba, Parana, Brazil
[2] James Hutton Inst, Aberdeen AB15 8QH, Scotland
[3] Policia Fed Parana, Setor Tecn & Cient, Curitiba, Parana, Brazil
来源
关键词
forensic science; soil evidence; sequential chemical analysis; gibbsite; iron oxides; MINERALS;
D O I
10.1590/18069657rbcs20190010
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
Soil traces are useful as forensic evidence due to their potential to transfer and adhere to different types of surfaces on a range of objects or persons. Several works have been developed in forensic soils, under different analytical approaches. However, in Brazil, only the researches from the Group of the Federal University of Parana have developed works with soils under a forensic approach. Focus has been given on the sequential chemical analyses and mineralogical techniques once they presented a large potential to discriminate soil samples, even that originated from the same bedrock. In this way, this work aimed to test a Standard Operating Procedure (SOP) for forensic soil sampling and an analytical protocol in Brazil between the academy and the scientific police through a blind simulated crime scene scenario. Samples were collected at four sites located in the Curitiba Metropolitan Region. All soils were classified as Inceptisol (Cambissolo), and the parent material in Curitiba is claystone and in Colombo is limestone. Around 3 g of sample composed by silt + clay fraction were isolated and analyzed by sequential chemical procedure: i) extraction of poorly ordered iron and aluminum oxides with ammonium oxalate (AO); ii) extraction of crystalline iron oxides with sodium dithionite-citrate-bicarbonate (DCB); and iii) extraction of poorly ordered aluminosilicates and gibbsite with NaOH 0.5 mol L-1 All data were transformed by square root and formed a data matrix subsequently analyzed in a principal component analysis (PCA). Most of the samples were properly grouped according to their provenance at all four sites tested, showing the potential of the Standard Operating Procedure (SOP) in a real crime scene. The sampling procedures presented in the SOP were detailed enough to allow the appropriate police work in forensic cases in any part of Brazil. As future considerations, modifications to the sample treatment and analytical protocol could be made depending on the context of the forensic work. Intense anthropogenic activities, such as domestic waste disposal in urban areas, would potentially reduce the discrimination power of such a proposed chemical analytical protocol.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Standard Operating Procedure (SOP) Antidiabetic Therapy with cardiovascular Benefit
    Niessner, A.
    Huber, K.
    Alber, H.
    Keta, D.
    Strametz-Juranek, J.
    Delle Karth, G.
    Frank, H.
    Vonbank, A.
    Wascher, T.
    JOURNAL FUR KARDIOLOGIE, 2020, 27 (11-12): : 402 - 404
  • [2] Establishment of the Standard Operating Procedure (SOP) for gathering digital evidence
    Lin, AC
    Lin, IL
    Lan, TH
    Wu, TC
    FIRST INTERNATIONAL WORKSHOP ON SYSTEMATIC APPROACHES TO DIGITAL FORENSIC ENGINEERING, PROCEEDINGS, 2005, : 56 - 65
  • [3] Isothermal titration calorimetry (ITC): a standard operating procedure (SOP)
    Bastos, Margarida
    Velazquez-Campoy, Adrian
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2021, 50 (3-4): : 363 - 371
  • [4] Isothermal titration calorimetry (ITC): a standard operating procedure (SOP)
    Margarida Bastos
    Adrian Velazquez-Campoy
    European Biophysics Journal, 2021, 50 : 363 - 371
  • [5] Standard operating procedure (SOP) for best care of periocular and intraocular lymphomas
    Schiemenz, Christian
    Kakkassery, Vinodh
    Heindl, Ludwig M.
    OPHTHALMOLOGIE, 2022, 119 (07): : 692 - 692
  • [6] Standard Operating Procedure (SOP) in patients with severe sepsis and septic shock: A resume after implementation of an evidence based standard operating procedure
    Schwab, T.
    Schmitz, A.
    Richter, S.
    Bode, C.
    Busch, H-J
    INFECTION, 2009, 37 : 65 - 66
  • [7] Auswirkung einer evidenzbasierten „standard operating procedure“ (SOP) auf das Therapieergebnis bei septischem SchockEffect of an evidence-based standard operating procedure (SOP) on outcome of septic shock
    S. Röhrig
    Der Anaesthesist, 2008, 57 (6) : 616 - 618
  • [8] Metagenomic Analysis and Validation of a Standard Operating Procedure
    Alves, E. A.
    Alves, D.
    Demolin, D.
    Minagawa, C.
    Santos, S.
    Gilioli, R.
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2012, 51 (05): : 670 - 670
  • [9] Evaluation of the Effectiveness of a Standard Operating Procedure (SOP) for the Perioperative Management of Colorectal Surgery
    Willis, Maria A.
    Engel, Felix M.
    Wiedemann, Charlotte
    van Beekum, Cornelius
    Coburn, Mark
    Thudium, Marcus
    Kalff, Joerg C.
    Vilz, Tim O.
    ZENTRALBLATT FUR CHIRURGIE, 2021, 146 (03): : 269 - 276
  • [10] Standard Operating Procedure (SOP) zur Versorgung von peri- und intraokulären LymphomenStandard operating procedure (SOP) for best care of periocular and intraocular lymphomas
    Christian Schiemenz
    Vinodh Kakkassery
    Ludwig M. Heindl
    Die Ophthalmologie, 2022, 119 : 692 - 692