Pulse pressure variation is not a valid predictor of fluid responsiveness in patients with elevated left ventricular filling pressure

被引:15
作者
Shim, Jae-Kwang [1 ,2 ]
Song, Jong-Wook [1 ,2 ]
Song, Young [1 ,2 ]
Kim, Ji-Ho [3 ]
Kang, Hye-Min [1 ]
Kwak, Young-Lan [1 ,2 ]
机构
[1] Yonsei Univ Hlth Syst, Dept Anesthesiol & Pain Med, Seoul 120752, South Korea
[2] Yonsei Univ Hlth Syst, Anesthesia & Pain Res Inst, Seoul 120752, South Korea
[3] Ilsan Hosp, Dept Anesthesiol & Pain Med, Natl Hlth Insurance Serv, Goyang City 410719, Gyeonggi Do, South Korea
关键词
Left ventricle; Filling pressure; Fluid responsiveness; Pulse pressure variation; DIASTOLIC HEART-FAILURE; EJECTION FRACTION; HEMODYNAMIC-RESPONSE; ECHOCARDIOGRAPHY; VOLUME; DIAGNOSIS; THERAPY; SURGERY; EDEMA;
D O I
10.1016/j.jcrc.2014.07.005
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: The purpose of this study was to test the hypothesis that the predictive ability of pulse pressure variation (PPV) for fluid responsiveness would be altered in patients with elevated left ventricular (LV) filling pressure. Materials and methods: According to the preoperative echocardiographic assessment of the ratio of early transmitral flow velocity to early diastolic velocity of the mitral annulus (E/E'), patients undergoing surgical coronary revascularization were classified into normal (n=34, E/E'<8) and high(n=34, E/E'>15) LV filling pressure group. After anesthetic induction, PPV and hemodynamic data were measured before and after 6 mL/kg of colloid administration. Fluid responsiveness was defined as 12% or more increase in stroke volume index assessed by pulmonary artery catheter and tested by the area under the receiver operating characteristic curve (AUROC). Results: The AUROCs of PPV in the normal and high filling pressure group were 0.829 (95% confidence interval [CI], 0.661-0.963; P < .001) and 0.583 (95% CI, 0.402-0.749; P = .110), respectively. The AUROCs of cardiac filling pressures and right ventricular end-diastolic volume index did not show statistical significance in both groups. Conclusions: None of the assessed preload indices including PPV were able to predict fluid responsiveness in patients with elevated LV filling pressure. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:987 / 991
页数:5
相关论文
共 23 条
[1]   Assessment of stress-induced pulmonary interstitial edema by chest ultrasound during exercise echocardiography and its correlation with left ventricular function [J].
Agricola, E ;
Picano, E ;
Oppizzi, M ;
Pisani, M ;
Meris, A ;
Fragasso, G ;
Margonato, A .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (04) :457-463
[2]   Heart failure with preserved ejection fraction: pathophysiology, diagnosis, and treatment [J].
Borlaug, Barry A. ;
Paulus, Walter J. .
EUROPEAN HEART JOURNAL, 2011, 32 (06) :670-+
[3]   Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality [J].
Boyd, John H. ;
Forbes, Jason ;
Nakada, Taka-aki ;
Walley, Keith R. ;
Russell, James A. .
CRITICAL CARE MEDICINE, 2011, 39 (02) :259-265
[4]   Left ventricular filling hemodynamics in patients with pulmonary edema and preserved versus reduced left ventricular ejection fraction: A prospective Doppler echocardiographic study [J].
Dabbah, Salim ;
Reisner, Shimon A. ;
Aronson, Doron ;
Agmon, Yoram .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (06) :733-743
[5]   Pulse pressure - A review of mechanisms and clinical relevance [J].
Dart, AM ;
Kingwell, BA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (04) :975-984
[6]   Intraoperative fluids: how much is too much? [J].
Doherty, M. ;
Buggy, D. J. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (01) :69-79
[7]   Decreased left ventricular distensibility in response to postural change in older patients with heart failure and preserved ejection fraction [J].
John, Jerry M. ;
Haykowsky, Mark ;
Brubaker, Peter ;
Stewart, Kathy ;
Kitzman, Dalane W. .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2010, 299 (03) :H883-H889
[8]   Prognostic value of a tissue Doppler-derived index of left ventricular filling pressure on composite morbidity after off-pump coronary artery bypass surgery [J].
Jun, N. H. ;
Shim, J. K. ;
Kim, J. C. ;
Kwak, Y. L. .
BRITISH JOURNAL OF ANAESTHESIA, 2011, 107 (04) :519-524
[9]   Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease [J].
Kim, So Yeon ;
Song, Young ;
Shim, Jae Kwang ;
Kwak, Young Lan .
JOURNAL OF CRITICAL CARE, 2013, 28 (03) :318.e1-318.e7
[10]   EXERCISE INTOLERANCE IN PATIENTS WITH HEART-FAILURE AND PRESERVED LEFT-VENTRICULAR SYSTOLIC FUNCTION - FAILURE OF THE FRANK-STARLING MECHANISM [J].
KITZMAN, DW ;
HIGGINBOTHAM, MB ;
COBB, FR ;
SHEIKH, KH ;
SULLIVAN, MJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (05) :1065-1072