Unrestricted linear dimensional changes of two hard chairside reline resins and one heat-curing acrylic resin

被引:13
作者
Cucci, ALM [1 ]
Giampaolo, ET [1 ]
Leonardi, P [1 ]
Vergani, CE [1 ]
机构
[1] UNIV SAO PAULO,ARARAQUARA DENT SCH,SAO PAULO,BRAZIL
基金
巴西圣保罗研究基金会;
关键词
D O I
10.1016/S0022-3913(96)90547-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The selection and use of hard chairside reline resins must be made with regard to dimensional stability, which will influence the accuracy of fit of the denture base. This study compared the dimensional change of two hard chairside reline resins (Duraliner II and Kooliner) and one heat-curing denture base resin (Lucitone 550). A stainless steel mold with reference dimensions (AB, CD) was used to obtain the samples. The materials were processed according to the manufacturer's recommendations. Measurements of the dimensions were made after processing and after the samples had been stored in distilled water at 37 degrees C for eight different periods of time. The data were recorded and then analyzed with analysis of variance. All materials showed shrinkage immediately after processing (p < 0.05). The only resin that exhibited shrinkage after 60 days of storage in water was Duraliner II; these changes could be clinically significant in regard of tissue fit.
引用
收藏
页码:414 / 417
页数:4
相关论文
共 20 条
[1]   A COMPARISON OF BOND STRENGTHS AMONG CHAIRSIDE HARD RELINE MATERIALS [J].
ARENA, CA ;
EVANS, DB ;
HILTON, TJ .
JOURNAL OF PROSTHETIC DENTISTRY, 1993, 70 (02) :126-131
[2]   CURRENT STATUS OF POUR TYPE DENTURE BASE RESINS [J].
BATES, JF ;
STAFFORD, GD ;
HUGGETT, R ;
HANDLEY, RW .
JOURNAL OF DENTISTRY, 1977, 5 (03) :177-189
[3]  
Craig R.G., 1992, DENT MAT PROPERTIES, P267
[4]   A NEW METHOD OF MEASURING DIMENSIONAL CHANGE [J].
DABREO, EL ;
HERMAN, P .
JOURNAL OF PROSTHETIC DENTISTRY, 1991, 65 (05) :718-722
[5]   LINEAR DIMENSIONAL VARIABILITY OF 3 DENTURE BASE RESINS AFTER PROCESSING AND IN WATER STORAGE [J].
DIXON, DL ;
BREEDING, LC ;
EKSTRAND, KG .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (01) :196-200
[6]   DIMENSIONAL ACCURACY OF POUR ACRYLIC RESIN AND CONVENTIONAL PROCESSING OF COLD-CURING ACRYLIC RESIN BASES [J].
GOODKIND, RJ ;
SCHULTE, RC .
JOURNAL OF PROSTHETIC DENTISTRY, 1970, 24 (06) :662-&
[8]   DIMENSIONAL ACCURACY AND STABILITY OF ACRYLIC RESIN DENTURE BASES [J].
HUGGETT, R ;
ZISSIS, A ;
HARRISON, A ;
DENNIS, A .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (04) :634-640
[9]  
*INT ORG STAND, 1988, 1567 INT ORG STAND
[10]   MECHANICAL-PROPERTIES OF TISSUE CONDITIONERS - THEORETICAL CONSIDERATIONS, BEHAVIORAL CHARACTERISTICS, AND TENSILE PROPERTIES [J].
MCCARTHY, JA ;
MOSER, JB .
JOURNAL OF PROSTHETIC DENTISTRY, 1978, 40 (01) :89-97