Material Selection Techniques for Polymer Hubs of Novel Spinal Stem Cell Introducers using Finite Element and Weighted Property Method

被引:4
作者
Irsyad, Muhammad [1 ]
Nadhif, Muhammad Hanif [1 ,2 ]
Rahyussalim, Ahmad Jabir [3 ]
Assyarify, Hanif [1 ]
Utomo, Muhammad Satrio [1 ,2 ,4 ]
机构
[1] Univ Indonesia, Fac Med, Inst Med Educ & Res Indonesia IMERI, Med Technol Cluster, JL Salemba Raya 6, Jakarta 10340, Indonesia
[2] Univ Indonesia, Fac Med, Dept Med Phys, JL Salemba Raya 6, Jakarta 10340, Indonesia
[3] Univ Indonesia, Ciptomangunkusumo Cent Hosp, Fac Med, Dept Orthoped & Traumatol, Jakarta 10430, Indonesia
[4] Indonesia Inst Sci LIPI, Res Ctr Met & Mat, Banten 15310, Indonesia
关键词
Finite element method introducer; Polymer; Spine; Weighting property method;
D O I
10.14716/ijtech.v11i5.4320
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Stem cell studies have progressed significantly in the last decades. Similarly, stem cell therapies have also been applied in clinical settings, includingthe spine. However, stem cells' delivery to the spinal region requires delicate procedures, demanding reliable introducers in addition to the surgeons' psychomotor skills. The introducer is a tubular sleeve to guide a syringe needle to deliver and draw fluids into and from the body, respectively. To date, there is no introducer dedicated to spinal stem cell deliveries. Our group proposed a dedicated introducer for spinal stem cell therapies, which consists of a needle and a hub (a base part of an introducer for gripping and handling). We focused onthe weighting property method (WPM) to select four polymer candidates for the hub:polystyrene, polycarbonate, polypropylene, and polyethylene. Prior to WPM, the mechanical integrity of the hub candidates was analyzed using the finite element method to determine the von Mises Stress (vMS) values. Accordingly, the vMS for each case and the material was compared with the respective tensile strength (TS), thereby vMS:TS ratio (MTR).MTR was included as one of the properties in WPM, in addition to prices, critical radiation doses, hardness, water absorption, and isopropyl alcohol resistance.According to the WPM calculation, polycarbonate received the highest score, thereby recommended for further introducer fabrications.
引用
收藏
页码:1056 / 1065
页数:10
相关论文
共 25 条
[1]  
[Anonymous], 2004, IEEE INT C INTELLIGE
[2]  
Black E., 2017, PLoS One, V12, P1, DOI [10.1371/journal.pone.0187974, DOI 10.1371/JOURNAL.PONE.0187974]
[3]  
Derby R., 2016, ADV CONCEPTS LUMBAR, P109
[4]   Stem cell therapy for the spinal cord [J].
Donnelly, Eleanor M. ;
Lamanna, Jason ;
Boulis, Nicholas M. .
STEM CELL RESEARCH & THERAPY, 2012, 3
[5]   Assessment of a new disposable introducer for spinal needles [J].
Erskine, R. J. .
ANAESTHESIA, 2008, 63 (11) :1238-1240
[6]   Optimisation of Process Parameters on Thin Shell Part Using Response Surface Methodology (RSM) [J].
Faiz, J. M. ;
Shayfull, Z. ;
Nasir, S. M. ;
Fathullah, M. ;
Rashidi, M. M. .
3RD ELECTRONIC AND GREEN MATERIALS INTERNATIONAL CONFERENCE 2017 (EGM 2017), 2017, 1885
[7]  
Farag M.M., 2013, MAT PROCESS SELECTIO, P291
[8]  
Foster Corporation, 2020, STER CHEM RES HEALTH
[9]   Cell therapy for lung disease [J].
Geiger, Sabine ;
Hirsch, Daniela ;
Hermann, Felix G. .
EUROPEAN RESPIRATORY REVIEW, 2017, 26 (144)
[10]  
Jujur IN, 2015, INT J TECHNOL, V6, P1184