Proton energy and scattering angle radiographs to improve proton treatment planning: a Monte Carlo study

被引:1
作者
Biegun, A. K. [1 ]
Takatsu, J. [2 ]
Nakaji, T. [2 ]
van Goethem, M. J. [1 ,3 ]
van der Graaf, E. R. [1 ]
Koffeman, E. N. [4 ]
Visser, J. [4 ]
Brandenburg, S. [1 ]
机构
[1] Univ Groningen, Adv Radiat Technol Ctr, KVI, Zernikelaan 25, NL-9747 AA Groningen, Netherlands
[2] Osaka Univ, Grad Sch Med, Dept Radiat Oncol, 2-2 D10 Yamadaoka, Suita, Osaka 5650871, Japan
[3] Univ Med Ctr Groningen, Dept Radiat Oncol, Univ Groningen Hanzeplein 1, NL-9700 RB Groningen, Netherlands
[4] Natl Inst Subat Phys Nikhef, Sci Pk 105, NL-1098 XG Amsterdam, Netherlands
关键词
Computerized Tomography (CT) and Computed Radiography (CR); Algoritms and Software for radiotherapy; Image reconstruction in medical imaging; Models and simulations; SIMULATION;
D O I
10.1088/1748-0221/11/12/C12015
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The novel proton radiography imaging technique has a large potential to be used in direct measurement of the proton energy loss (proton stopping power, PSP) in various tissues in the patient. The uncertainty of PSPs, currently obtained from translation of X-ray Computed Tomography (xCT) images, should be minimized from 3-5% or higher to less than 1%, to make the treatment plan with proton beams more accurate, and thereby better treatment for the patient. With Geant4 we simulated a proton radiography detection system with two position-sensitive and residual energy detectors. A complex phantom filled with various materials (including tissue surrogates), was placed between the position sensitive detectors. The phantom was irradiated with 150 MeVprotons and the energy loss radiograph and scattering angles were studied. Protons passing through different materials in the phantom lose energy, which was used to create a radiography image of the phantom. The multiple Coulomb scattering of a proton traversing different materials causes blurring of the image. To improve image quality and material identification in the phantom, we selected protons with small scattering angles. A good quality proton radiography image, in which various materials can be recognized accurately, and in combination with xCT can lead to more accurate relative stopping powers predictions.
引用
收藏
页数:8
相关论文
共 9 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   PROTON RADIOGRAPHY TO IMPROVE PROTON RADIOTHERAPY: SIMULATION STUDY AT DIFFERENT PROTON BEAM ENERGIES [J].
Biegun, A. K. ;
Takatsu, J. ;
van Goethem, M-J. ;
van der Graaf, E. R. ;
van Beuzekom, M. ;
Visser, J. ;
Brandenburg, S. .
ACTA PHYSICA POLONICA B, 2016, 47 (02) :329-334
[3]   Proton Radiography With Timepix Based Time Projection Chambers [J].
Biegun, Aleksandra K. ;
Visser, Jan ;
Klaver, Tom ;
Ghazanfari, Nafiseh ;
van Goethem, Marc-Jan ;
Koffeman, Els ;
van Beuzekom, Martin ;
Brandenburg, Sytze .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (04) :1099-1105
[4]   200 MeV Proton Radiography Studies With a Hand Phantom Using a Prototype Proton CT Scanner [J].
Plautz, Tia ;
Bashkirov, V. ;
Feng, V. ;
Hurley, F. ;
Johnson, R. P. ;
Leary, C. ;
Macafee, S. ;
Plumb, A. ;
Rykalin, V. ;
Sadrozinski, H. F. -W. ;
Schubert, K. ;
Schulte, R. ;
Schultze, B. ;
Steinberg, D. ;
Witt, M. ;
Zatserklyaniy, A. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (04) :875-881
[5]   Proton radiography and tomography with application to proton therapy [J].
Poludniowski, G. ;
Allinson, N. M. ;
Evans, P. M. .
BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1053)
[6]   Density and spatial resolutions of proton radiography using a range modulation technique [J].
Ryu, Hyungjoon ;
Song, Eunsuk ;
Lee, Jaeki ;
Kim, Jongwon .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (19) :5461-5468
[7]   MULTIPLE COULOMB SCATTERING AND SPATIAL-RESOLUTION IN PROTON RADIOGRAPHY [J].
SCHNEIDER, U ;
PEDRONI, E .
MEDICAL PHYSICS, 1994, 21 (11) :1657-1663
[8]   A proton Computed Tomography system for medical applications [J].
Sipala, V. ;
Bruzzi, M. ;
Bucciolini, M. ;
Carpinelli, M. ;
Cirrone, G. A. P. ;
Civinini, C. ;
Cuttone, G. ;
Lo Presti, D. ;
Pallotta, S. ;
Pugliatti, C. ;
Randazzo, N. ;
Romano, F. ;
Scaringella, M. ;
Stancampiano, C. ;
Talamonti, C. ;
Tesi, M. ;
Vanzi, E. ;
Zani, M. .
JOURNAL OF INSTRUMENTATION, 2013, 8
[9]   Proton radiography to improve proton therapy treatment [J].
Takatsu, J. ;
van der Graaf, E. R. ;
Van Goethem, M. -J. ;
van Beuzekom, M. ;
Klaver, T. ;
Visser, J. ;
Brandenburg, S. ;
Biegun, A. K. .
JOURNAL OF INSTRUMENTATION, 2016, 11