Arthroscopic Management of Glenoid and Greater Tuberosity Bipolar Fractures

被引:9
|
作者
Zhang, Qing [1 ]
Xiang, Ming [1 ]
Li, Yi-ping [1 ]
Yang, Jin-song [1 ]
机构
[1] Sichuan Prov Orthpaed Hosp, Dept Upper Limb, Chengdu 610041, Sichuan, Peoples R China
关键词
Arthroscopy; Glenoid fracture; Greater tuberosity fracture; Shoulder; Surgical treatment; SHOULDER DISLOCATION; EPIDEMIOLOGY;
D O I
10.1111/os.12786
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To report the clinical and radiological outcomes of arthroscopically assisted surgery for combination of glenoid and greater tuberosity fractures after traumatic shoulder dislocation. Methods From December 2013 to December 2018, patients with concomitant fracture of the greater tuberosity and glenoid who underwent arthroscopically assisted surgery were retrospectively reviewed. Fifteen patients were included. Preoperative computed tomography (CT) scans with 3D reconstruction were performed to evaluate the fracture configuration and associated fractures. All patients underwent arthroscopically assisted surgery under general anesthesia with brachial plexus anesthesia in the lateral position. Under the arthroscopic approach, a comprehensive inspection of the joints was firstly conducted to examine the injury of bones and other tissues. With arthroscopy support, closed reduction and internal fixation of both fractures were performed with suture anchors, with or without additional cannulated screws. At the same time, other injuries were also repaired under the arthroscope. Patients were followed up (6 weeks?8 weeks?3 months?6 months?1 year after surgery) regularly for at least 1 year. At the follow-up, clinical outcomes (Constant score, ASES score, range of motion, and VAS score) and radiological outcomes were analyzed. Results Of the 15 patients, there are seven cases of men, eight cases of women; aged 22-66 years, with an average age of 48 years; left shoulder for five cases, 10 cases of the right shoulder. The injury mechanisms were: a simple fall (n = 9), an epileptic seizure (n = 1), a high fall injury (n = 2), and a traffic accident (n = 3). Of the 15 cases of glenoid fracture, 11 cases were type Ia and four cases were type II according to the Ideberg Classification System. The mean size of the glenoid fracture fragment was 28.4% (range, 8.7%-47.2%). According to the Mutch classification system, the fractures of the greater tuberosity were divided into: five cases of avulsion, one case of compression, and nine cases of split. Average time of follow-up was 38.2 months (range, 12-70 months), and one case was lost to follow-up. With fractures healing well, almost all patients had a good joint function. At the final follow-up, mean anterior flexion was 157 degrees; mean external rotation was 40 degrees; mean internal rotation was T(11)level; the mean Constant-Murley score was 94.6 points (range, 70-100 points); the mean ASES score was 94.6 points (range, 79-100 points); and the mean VAS score was 0.4 points (range, 0-2 points). No recurrent instability or re-dislocation occurred. No patient had revision surgery. Conclusion Arthroscopic management of glenoid and greater tuberosity bipolar fractures was useful and effective with minimal injury, and it achieved satisfactory clinical and radiological outcomes at a mean follow-up time of more than 3 years.
引用
收藏
页码:1405 / 1412
页数:8
相关论文
共 50 条
  • [41] Evaluation and Management of Pediatric Proximal Humerus Greater and Lesser Tuberosity Avulsion Fractures
    Niu, Emily
    Nowell, Jared A.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2024, 32 (23) : e1196 - e1204
  • [42] Arthroscopic treatment of acute traumatic anterior glenohumeral dislocation and greater tuberosity fracture
    Gartsman, GM
    Taverna, E
    Hammerman, SM
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1999, 15 (06) : 648 - 650
  • [43] A simple and effective implant for displaced fractures of the greater tuberosity: the “Bamberg” plate
    Volker Schöffl
    Dominik Popp
    Wolf Strecker
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 509 - 512
  • [44] A simple and effective implant for displaced fractures of the greater tuberosity: the "Bamberg" plate
    Schoeffl, Volker
    Popp, Dominik
    Strecker, Wolf
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (04) : 509 - 512
  • [45] Isolated fractures of the greater tuberosity: When are they treated conservatively? A baseline study
    Schliemann, Benedikt
    Heilmann, Lukas F.
    Raschke, Michael J.
    Lill, Helmut
    Katthagen, J. Christoph
    Ellwein, Alexander
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2018, 13 (02): : 106 - 111
  • [46] NONDISPLACED FRACTURES OF THE GREATER TUBEROSITY OF THE HUMERUS - SONOGRAPHIC DETECTION
    PATTEN, RM
    MACK, LA
    WANG, KY
    LINGEL, J
    RADIOLOGY, 1992, 182 (01) : 201 - 204
  • [47] Radiological and biomechanical assessment of displaced greater tuberosity fractures
    Richard W. Nyffeler
    Angela Seidel
    Stefan Werlen
    Mathias Bergmann
    International Orthopaedics, 2019, 43 : 1479 - 1486
  • [48] Radiological and biomechanical assessment of displaced greater tuberosity fractures
    Nyffeler, Richard W.
    Seidel, Angela
    Werlen, Stefan
    Bergmann, Mathias
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (06) : 1479 - 1486
  • [49] Surgical Treatment of Displaced Greater Tuberosity Fractures of the Humerus
    Rouleau, Dominique M.
    Mutch, Jennifer
    Laflamme, Georges-Yves
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2016, 24 (01) : 46 - 56
  • [50] Arthroscopic refixation of a combined fracture of the greater and lesser tuberosity of the proximal humerus
    S. Pauly
    S. Herrmann
    C. Perka
    S. Greiner
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 1171 - 1175