Arthroscopic Management of Glenoid and Greater Tuberosity Bipolar Fractures

被引:9
|
作者
Zhang, Qing [1 ]
Xiang, Ming [1 ]
Li, Yi-ping [1 ]
Yang, Jin-song [1 ]
机构
[1] Sichuan Prov Orthpaed Hosp, Dept Upper Limb, Chengdu 610041, Sichuan, Peoples R China
关键词
Arthroscopy; Glenoid fracture; Greater tuberosity fracture; Shoulder; Surgical treatment; SHOULDER DISLOCATION; EPIDEMIOLOGY;
D O I
10.1111/os.12786
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To report the clinical and radiological outcomes of arthroscopically assisted surgery for combination of glenoid and greater tuberosity fractures after traumatic shoulder dislocation. Methods From December 2013 to December 2018, patients with concomitant fracture of the greater tuberosity and glenoid who underwent arthroscopically assisted surgery were retrospectively reviewed. Fifteen patients were included. Preoperative computed tomography (CT) scans with 3D reconstruction were performed to evaluate the fracture configuration and associated fractures. All patients underwent arthroscopically assisted surgery under general anesthesia with brachial plexus anesthesia in the lateral position. Under the arthroscopic approach, a comprehensive inspection of the joints was firstly conducted to examine the injury of bones and other tissues. With arthroscopy support, closed reduction and internal fixation of both fractures were performed with suture anchors, with or without additional cannulated screws. At the same time, other injuries were also repaired under the arthroscope. Patients were followed up (6 weeks?8 weeks?3 months?6 months?1 year after surgery) regularly for at least 1 year. At the follow-up, clinical outcomes (Constant score, ASES score, range of motion, and VAS score) and radiological outcomes were analyzed. Results Of the 15 patients, there are seven cases of men, eight cases of women; aged 22-66 years, with an average age of 48 years; left shoulder for five cases, 10 cases of the right shoulder. The injury mechanisms were: a simple fall (n = 9), an epileptic seizure (n = 1), a high fall injury (n = 2), and a traffic accident (n = 3). Of the 15 cases of glenoid fracture, 11 cases were type Ia and four cases were type II according to the Ideberg Classification System. The mean size of the glenoid fracture fragment was 28.4% (range, 8.7%-47.2%). According to the Mutch classification system, the fractures of the greater tuberosity were divided into: five cases of avulsion, one case of compression, and nine cases of split. Average time of follow-up was 38.2 months (range, 12-70 months), and one case was lost to follow-up. With fractures healing well, almost all patients had a good joint function. At the final follow-up, mean anterior flexion was 157 degrees; mean external rotation was 40 degrees; mean internal rotation was T(11)level; the mean Constant-Murley score was 94.6 points (range, 70-100 points); the mean ASES score was 94.6 points (range, 79-100 points); and the mean VAS score was 0.4 points (range, 0-2 points). No recurrent instability or re-dislocation occurred. No patient had revision surgery. Conclusion Arthroscopic management of glenoid and greater tuberosity bipolar fractures was useful and effective with minimal injury, and it achieved satisfactory clinical and radiological outcomes at a mean follow-up time of more than 3 years.
引用
收藏
页码:1405 / 1412
页数:8
相关论文
共 50 条
  • [21] Arthroscopic assisted fixation of glenoid fractures
    Glaab, R.
    Seybold, D.
    ARTHROSKOPIE, 2018, 31 (01) : 2 - 8
  • [22] Clinical and radiologic outcomes of arthroscopic suture bridge repair for the greater tuberosity fractures of the proximal humerus
    Jong-Hun Ji
    Jae-Jung Jeong
    Young-Yul Kim
    Se-Won Lee
    Do-Yeol Kim
    Sang-Eun Park
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 9 - 17
  • [23] Arthroscopic double-row suture anchor fixation of minimally displaced greater tuberosity fractures
    Ji, Jong-Hun
    Kim, Weon-Yoo
    Ra, Ki-Hang
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (10) : 1133.e1 - 1133.e4
  • [24] Arthroscopic treatment of greater tuberosity fractures : retrospective review of clinical and radiological outcomes
    Choi, Sungwook
    Son, Inseok
    Hyun, Myung Jae
    Bae, Jong-Hwan
    Kang, Hyunseong
    ACTA ORTHOPAEDICA BELGICA, 2018, 84 (01): : 47 - 53
  • [25] Arthroscopic treatment of symptomatic shoulders with minimally displaced greater tuberosity fracture
    Kim, SH
    Ha, KI
    ARTHROSCOPY, 2000, 16 (07): : 695 - 700
  • [26] Associated injuries with greater tuberosity fractures. Mechanism of injury, diagnostics, treatment
    Muhm, M.
    Arend, S.
    Winkler, H.
    Ruffing, T.
    UNFALLCHIRURG, 2017, 120 (10): : 854 - 864
  • [27] Arthroscopic treatment of glenoid fractures
    Bauer, Thomas
    Abadie, Olivier
    Hardy, Philippe
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (05) : 569.e1 - 569.e6
  • [28] Missed fractures of the greater tuberosity
    Longo, Umile Giuseppe
    Corbett, Steven
    Ahrens, Philip Michael
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [29] Missed fractures of the greater tuberosity
    Umile Giuseppe Longo
    Steven Corbett
    Philip Michael Ahrens
    BMC Musculoskeletal Disorders, 19
  • [30] Plate Fixation versus Arthroscopic-Assisted Plate Fixation for Isolated Medium-Sized Fractures of the Greater Tuberosity: A Retrospective Study
    Sun, Qi
    Ge, Wei
    Li, Gen
    Wu, Jie Zhou
    Lu, Guanghua
    Li, Runmin
    Zhao, Zhenyu
    Zhu, Yaru
    Xu, Youzhi
    Lei, Wang
    Cai, Ming
    ORTHOPAEDIC SURGERY, 2020, 12 (05) : 1456 - 1463