High sensitivity cardiac troponin T in patients with immunoglobulin light chain amyloidosis

被引:59
作者
Dispenzieri, A. [1 ]
Gertz, M. A. [1 ]
Kumar, S. K. [1 ]
Lacy, M. Q. [1 ]
Kyle, R. A. [1 ]
Saenger, A. K. [2 ]
Grogan, M. [3 ]
Zeldenrust, S. R. [1 ]
Hayman, S. R. [1 ]
Buadi, F. [1 ]
Greipp, P. R. [1 ]
Leung, N. [4 ]
Russell, S. R. [5 ]
Dingli, D. [1 ]
Lust, J. A. [1 ]
Rajkumar, S. V. [1 ]
Jaffe, A. S. [2 ,3 ]
机构
[1] Mayo Clin, Div Hematol & Internal Med, Rochester, MN 55905 USA
[2] Mayo Clin, Div Clin Core Lab Serv, Dept Lab Med & Pathol, Rochester, MN 55905 USA
[3] Mayo Clin, Div Cardiovasc Dis & Internal Med, Rochester, MN 55905 USA
[4] Mayo Clin, Div Nephrol & Hypertens, Rochester, MN 55905 USA
[5] Mayo Clin, Div Mol Med, Rochester, MN 55905 USA
关键词
PRIMARY SYSTEMIC AMYLOIDOSIS; BRAIN NATRIURETIC PEPTIDE; STEM-CELL TRANSPLANTATION; AL AMYLOIDOSIS; HEART-FAILURE; MORTALITY RISK; ASSAY; SURVIVAL; DISEASE; DEXAMETHASONE;
D O I
10.1136/heartjnl-2013-304957
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To define whether the high sensitivity cardiac troponin T (hs-cTnT) assay in patients with immunoglobulin light chain amyloidosis (AL) improves risk prediction. Background Cardiac involvement is the major cause of death in patients with AL amyloidosis. Risk stratification is facilitated by cardiac biomarkers such as cardiac troponin T (cTnT) and N-terminal pro B-type natriuretic peptide (NT-proBNP). Methods Stored serum from patients with newly diagnosed AL was used to measure hs-cTnT, cTnT, and NT-proBNP. Survival modelling was performed. Results The direct numeric result from hs-cTnT measurement cannot merely be substituted for a cTnT measurement in the Mayo AL staging system. The performance of the receiver operator curve derived an hs-cTnT cut-point of 54ng/L which improves on the value of 35ng/L validated with the prior iteration of the assay. An alternate staging option using hs-cTnT aloneusing the two thresholds 14ng/L and 54ng/Lperforms as well as either the original Mayo AL staging system or other systems incorporating hs-cTnT. On multivariate analysis, an hs-cTnT alone staging system was independent of period of diagnosis, type of therapy, and NT-proBNP value, the last of which dropped out of the model. Alternate models were explored, but none performed better than the original system or the new hs-cTnT system. Thus, hs-cTnT can be used alone for the staging of disease prognosis. Conclusions A survival model based on hs-cTnT improves the prognostic staging of patients with AL amyloidosis, relegating NT-proBNP to a measure of cardiac response.
引用
收藏
页码:383 / 388
页数:6
相关论文
共 30 条
[21]   A Sensitive Cardiac Troponin T Assay in Stable Coronary Artery Disease [J].
Omland, Torbjorn ;
de Lemos, James A. ;
Sabatine, Marc S. ;
Christophi, Costas A. ;
Rice, Madeline Murguia ;
Jablonski, Kathleen A. ;
Tjora, Solve ;
Domanski, Michael J. ;
Gersh, Bernard J. ;
Rouleau, Jean L. ;
Pfeffer, Marc A. ;
Braunwald, Eugene .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (26) :2538-2547
[22]   Serum N-terminal pro-brain natriuretic peptide is a sensitive marker of myocardial dysfunction in AL amyloidosis [J].
Palladini, G ;
Campana, C ;
Klersy, C ;
Balduini, A ;
Vadacca, G ;
Perfetti, V ;
Perlini, S ;
Obici, L ;
Ascari, E ;
d'Eril, GM ;
Moratti, R ;
Merlini, G .
CIRCULATION, 2003, 107 (19) :2440-2445
[23]   Circulating amyloidogenic free light chains and serum N-terminal natriuretic peptide type B decrease simultaneously in association with improvement of survival in AL [J].
Palladini, Giovanni ;
Lavatelii, Francesca ;
Russo, Paola ;
Perlini, Stefano ;
Perfetti, Vittorio ;
Bosoni, Tiziana ;
Obici, Laura ;
Bradwell, Arthur R. ;
D'Eril, GianVico Melzi ;
Fogari, Roberto ;
Moratti, Remigio ;
Merlini, Giampaolo .
BLOOD, 2006, 107 (10) :3854-3858
[24]   The combination of high-sensitivity cardiac troponin T (hs-cTnT) at presentation and changes in N-terminal natriuretic peptide type B (NT-proBNP) after chemotherapy best predicts survival in AL amyloidosis [J].
Palladini, Giovanni ;
Barassi, Alessandra ;
Klersy, Catherine ;
Pacciolla, Rosana ;
Milani, Paolo ;
Sarais, Gabriele ;
Perlini, Stefano ;
Albertini, Riccardo ;
Russo, Paola ;
Foli, Andrea ;
Bragotti, Letizia Zenone ;
Obici, Laura ;
Moratti, Remigio ;
d'Eril, Gian Vico Melzi ;
Merlini, Giampaolo .
BLOOD, 2010, 116 (18) :3426-3430
[25]   Diagnostic and Prognostic Utility of Cardiovascular Magnetic Resonance Imaging in Light-Chain Cardiac Amyloidosis [J].
Ruberg, Frederick L. ;
Appelbaum, Evan ;
Davidoff, Ravin ;
Ozonoff, Al ;
Kissinger, Kraig V. ;
Harrigan, Caitlin ;
Skinner, Martha ;
Manning, Warren J. .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (04) :544-549
[26]   Multicenter analytical evaluation of a high-sensitivity troponin T assay [J].
Saenger, A. K. ;
Beyrau, R. ;
Braun, S. ;
Cooray, R. ;
Dolci, A. ;
Freidank, H. ;
Giannitsis, E. ;
Gustafson, S. ;
Handy, B. ;
Katus, H. ;
Melanson, S. E. ;
Panteghini, M. ;
Venge, P. ;
Zorn, M. ;
Jarolim, P. ;
Bruton, D. ;
Jarausch, J. ;
Jaffe, A. S. .
CLINICA CHIMICA ACTA, 2011, 412 (9-10) :748-754
[27]   Cardiac Troponin T Measured by a Highly Sensitive Assay Predicts Coronary Heart Disease, Heart Failure, and Mortality in the Atherosclerosis Risk in Communities Study [J].
Saunders, Justin T. ;
Nambi, Vijay ;
de Lemos, James A. ;
Chambless, Lloyd E. ;
Virani, Salim S. ;
Boerwinkle, Eric ;
Hoogeveen, Ron C. ;
Liu, Xiaoxi ;
Astor, Brad C. ;
Mosley, Thomas H. ;
Folsom, Aaron R. ;
Heiss, Gerardo ;
Coresh, Josef ;
Ballantyne, Christie M. .
CIRCULATION, 2011, 123 (13) :1367-U65
[28]   Normal Plasma Levels of Cardiac Troponin I Measured by the High-Sensitivity Cardiac Troponin I Access Prototype Assay and the Impact on the Diagnosis of Myocardial Ischemia [J].
Venge, Per ;
Johnston, Nina ;
Lindahl, Bertil ;
James, Stefan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (13) :1165-1172
[29]   Biological variation for N-terminal pro- and B-type natriuretic peptides and implications for therapeutic monitoring of patients with congestive heart failure [J].
Wu, AHB ;
Smith, A ;
Wieczorek, S ;
Mather, JF ;
Duncan, B ;
White, CM ;
McGill, C ;
Katten, D ;
Heller, G .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (05) :628-631
[30]   Development and preliminary clinical validation of a high sensitivity assay for cardiac troponin using a capillary flow (Single molecule) fluorescence detector [J].
Wu, Alan H. B. ;
Fukushima, Noelle ;
Puskas, Robert ;
Todd, John ;
Goix, Philippe .
CLINICAL CHEMISTRY, 2006, 52 (11) :2157-2159