Thermodynamic performance assessment of a small size CCHP (combined cooling heating and power) system with numerical models

被引:41
作者
Jannelli, E. [1 ]
Minutillo, M. [1 ]
Cozzolino, R. [2 ]
Falcucci, G. [1 ]
机构
[1] Univ Naples Parthenope, Ctr Direz, I-80143 Naples, Italy
[2] Univ Niccolo Cusano, Rome, Italy
关键词
Polygeneration; Diesel engine; Absorption chiller; Numerical models; Performance coefficients; TRIGENERATION SYSTEMS; GENERATION SYSTEM; DESIGN; COGENERATION; CRITERION;
D O I
10.1016/j.energy.2013.11.074
中图分类号
O414.1 [热力学];
学科分类号
摘要
The aim of the this work has been to evaluate the performance of a small-size CCHP (Combined Cooling Heating and Power) system based on the integration of 20 kW Lombardini diesel engine and a double effect water-LiBr absorption chiller. This integrated system has been designed to produce both hot water, by recovering heat from the engine cooling system, and chilled water, by recovering heat from the engine exhaust gasses (the exhaust gasses are sent to the fired-combustor of the absorption chiller). The analysis has been conducted by using numerical simulations: the engine and the absorption chiller have been modeled by means of 0-1D dimensional and thermochemical models, respectively, and the validation procedure has been performed by using the available operating data. The system performance has been calculated by introducing some performance parameters that have allowed: i) to estimate the efficiency of the primary energy conversion into useful energy EUF (energy utilization factor), ii) to consider the quality difference between cool/heat and work and among heats at different temperatures ExUF (exergy utilization factor); iii) to evaluate the primary energy saving with respect to the separate production of the same energy fluxes TPES (trigeneration primary energy saving). (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:240 / 249
页数:10
相关论文
共 31 条
[1]   Performance comparison of three trigeneration systems using organic rankine cycles [J].
Al-Sulaiman, Fahad A. ;
Hamdullahpur, Feridun ;
Dincer, Ibrahim .
ENERGY, 2011, 36 (09) :5741-5754
[2]   A mixed integer programming model for optimal design of trigeneration in a hospital complex [J].
Arcuri, P. ;
Florio, G. ;
Fragiacomo, P. .
ENERGY, 2007, 32 (08) :1430-1447
[3]   Thermodynamic and thermoeconomic analyses of a trigeneration (TRIGEN) system with a gas-diesel engine: Part II - An application [J].
Balli, Ozgur ;
Aras, Haydar ;
Hepbasli, Arif .
ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (11) :2260-2271
[4]   Thermodynamic and thermoeconomic analyses of a trigeneration (TRIGEN) system with a gas-diesel engine: Part I - Methodology [J].
Balli, Ozgur ;
Aras, Haydar ;
Hepbasli, Arif .
ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (11) :2252-2259
[5]   Exergy based performance analysis of high efficiency poly-generation systems for sustainable building applications [J].
Bingol, Ekin ;
Kilkis, Birol ;
Eralp, Cahit .
ENERGY AND BUILDINGS, 2011, 43 (11) :3074-3081
[6]   Performance analysis of combined microgas turbines and gas fired water/LiBr absorption chillers with post-combustion [J].
Bruno, JC ;
Valero, A ;
Coronas, A .
APPLIED THERMAL ENGINEERING, 2005, 25 (01) :87-99
[7]  
Chen Q, 2012, P ECOS 2012 25 INT C
[8]   Trigeneration primary energy saving evaluation for energy planning and policy development [J].
Chicco, Gianfranco ;
Mancarella, Pierluigi .
ENERGY POLICY, 2007, 35 (12) :6132-6144
[9]   Feasibility of polygeneration in energy supply systems for health-care facilities under the Italian climate and boundary conditions [J].
Fabrizio, Enrico .
ENERGY FOR SUSTAINABLE DEVELOPMENT, 2011, 15 (01) :92-103
[10]   A new performance criterion for cogeneration system [J].
Feng, X ;
Cai, YN ;
Qian, LL .
ENERGY CONVERSION AND MANAGEMENT, 1998, 39 (15) :1607-1609