Lateral flow biosensor for DNA extraction-free detection of salmonella based on aptamer mediated strand displacement.amplification

被引:144
作者
Fang, Zhiyuan [1 ]
Wu, Wei [1 ]
Lu, Xuewen [1 ]
Zeng, Lingwen [1 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Biomed & Hlth, Key Lab Regenerat Biol, Guangzhou 510530, Guangdong, Peoples R China
关键词
Lateral flow biosensor; Salmonella; Aptamer; Point-of-care; POLYMERASE-CHAIN-REACTION; ESCHERICHIA-COLI O157H7; MULTIPLEX PCR ASSAY; REAL-TIME PCR; QUANTIFICATION; TYPHIMURIUM; BACTERIA; ENTERICA; SEPARATION; OUTBREAK;
D O I
10.1016/j.bios.2014.01.015
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Convenient and sensitive point-of-care rapid diagnostic tests for food-borne pathogens have been a long-felt need of clinicians. Traditional approaches such as culture-based methods have good sensitivity and specificity, but they tend to be tedious and time-consuming. Herein we present a simple and sensitive aptamer based biosensor for rapid detection of Salmonella enteritidis (S. enteritidis). One of the aptamers specific for the outmembrane of S. enteritidis was used for magnetic bead enrichments. Another aptamer against S. enteritidis was used as a reporter for this pathogen, which was amplified by isothermal strand displacement amplification (SDA) and further detected by a lateral flow biosensor. As low as 10(1) colony forming unit (CFU) of S. enteritidis was detected in this study. Without DNA extraction, the reduced handling and simpler equipment requirement render this assay a simple and rapid alternative to conventional methods. (C) 2014 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
引用
收藏
页码:192 / 197
页数:6
相关论文
共 40 条
[21]   Effect of washing with a high pressure water spray on removal of Listeria innocua from Gorgonzola cheese rind [J].
Mucchetti, Germano ;
Bonvini, Barbara ;
Francolino, Salvatore ;
Neviani, Erasmo ;
Carminati, Domenico .
FOOD CONTROL, 2008, 19 (05) :521-525
[22]   Characteristics of children with sporadic hemolytic uremic syndrome in a single Northern California center [J].
Oh, Gia ;
Lau, Keith K. .
INTERNATIONAL UROLOGY AND NEPHROLOGY, 2012, 44 (05) :1467-1472
[23]   Immunomagnetic nanoparticle-based sandwich chemiluminescence-ELISA for the enrichment and quantification of E. coli [J].
Pappert, Gerhard ;
Rieger, Martin ;
Niessner, Reinhard ;
Seidel, Michael .
MICROCHIMICA ACTA, 2010, 168 (1-2) :1-8
[24]   Multiplex PCR assay for the detection and quantification of Campylobacter spp., Escherichia coli O157:H7, and Salmonella serotypes in water samples [J].
Park, Si Hong ;
Hanning, Irene ;
Jarquin, Robin ;
Moore, Philip ;
Donoghue, Dan J. ;
Donoghue, Ann M. ;
Ricke, Steven C. .
FEMS MICROBIOLOGY LETTERS, 2011, 316 (01) :7-15
[25]   Aptamers against extracellular targets for in vivo applications [J].
Pestourie, C ;
Tavitian, B ;
Duconge, F .
BIOCHIMIE, 2005, 87 (9-10) :921-930
[26]  
Peterson I.W., 1996, BACTERIAL PATHOGENES
[27]   An outbreak of febrile gastroenteritis associated with jellied pork contaminated with Listeria monocytogenes [J].
Pichler, Juliane ;
Much, Peter ;
Kasper, Sabine ;
Fretz, Rainer ;
Auer, Bettina ;
Kathan, Julia ;
Mann, Michaela ;
Huhulescu, Steliana ;
Ruppitsch, Werner ;
Pietzka, Ariane ;
Silberbauer, Karl ;
Neumann, Christian ;
Gschiel, Ernst ;
de Martin, Alfred ;
Schuetz, Angelika ;
Gindl, Josef ;
Neugschwandtner, Ernst ;
Allerberger, Franz .
WIENER KLINISCHE WOCHENSCHRIFT, 2009, 121 (3-4) :149-156
[28]  
Pui Chai Fung, 2011, Trop Med Health, V39, P9, DOI 10.2149/tmh.2010-20
[29]  
Raguenaud ME, 2012, EUROSURVEILLANCE, V17, P11