Steel hysteretic column dampers for seismic retrofit of soft-first-story structures

被引:40
作者
Javidan, Mohammad Mandi [1 ]
Kim, Jinkoo [1 ]
机构
[1] Sungkyunkwan Univ, Dept Civil & Architectural Engn, Suwon, South Korea
关键词
seismic retrofit; soft story; hysteretic dampers; seismic performance; energy dissipation device; PERFORMANCE EVALUATION; OPTIMUM DISTRIBUTION; SLIT DAMPERS; FRAMES; MITIGATION; BUILDINGS; BEHAVIOR; DESIGN;
D O I
10.12989/scs.2020.37.3.259
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study a new hysteretic damper for seismic retrofit of soft-first story structures is proposed and its seismic retrofit effect is evaluated. The damper consists of one steel column member and two flexural fuses at both ends made of steel plates with reduced section, which can be placed right beside existing columns in order to minimize interference with passengers and automobiles in the installed bays. The relative displacement between the stories forms flexural plastic hinges at the fuses and dissipate seismic energy. The theoretical formulation and the design procedure based on plastic analysis is provided for the proposed damper, and the results are compared with a detailed finite-element (FE) model. In order to apply the damper in structural analysis, a macromodel of the damper is also developed and calibrated by the derived theoretical formulas. The results are compared with the detailed FE analysis, and the efficiency of the damper is further validated by the seismic retrofit of a case study structure and assessing its seismic performance before and after the retrofit. The results show that the proposed hysteretic damper can be used effectively in reducing damage to soft-first story structures.
引用
收藏
页码:259 / 272
页数:14
相关论文
共 45 条
[21]   Seismic behavior factors of buckling-restrained braced frames [J].
Kim, Jinkoo ;
Park, Junhee ;
Kim, Sang-Dae .
STRUCTURAL ENGINEERING AND MECHANICS, 2009, 33 (03) :261-284
[22]   Behavior and design of structures with buckling-restrained braces [J].
Kim, JK ;
Choi, HH .
ENGINEERING STRUCTURES, 2004, 26 (06) :693-706
[23]   Development of box-shaped steel slit dampers for seismic retrofit of building structures [J].
Lee, Joonho ;
Kim, Jinkoo .
ENGINEERING STRUCTURES, 2017, 150 :934-946
[24]   Seismic performance of steel plate slit-friction hybrid dampers [J].
Lee, Joonho ;
Kang, Hyungoo ;
Kim, Jinkoo .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 136 :128-139
[25]   A shear wall element for nonlinear seismic analysis of super-tall buildings using OpenSees [J].
Lu, Xinzheng ;
Xie, Linlin ;
Guan, Hong ;
Huang, Yuli ;
Lu, Xiao .
FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2015, 98 :14-25
[26]   Techno-economic-environmental study of hybrid power supply system: A case study in Iran [J].
Mehrpooya, Mehdi ;
Mohammadi, Mohammad ;
Ahmadi, Esmaeil .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2018, 25 :1-10
[27]  
Menegotto M., 1973, PROC IABSE S RESISTA
[28]   Performance of innovative composite buckling-restrained fuse for concentrically braced frames under cyclic loading [J].
Mohammadi, Masoud ;
Kafi, Mohammad A. ;
Kheyroddin, Ali ;
Ronagh, Hamid R. .
STEEL AND COMPOSITE STRUCTURES, 2020, 36 (02) :163-177
[29]   Performance of steel frames with a new friction damper device under earthquake excitation [J].
Mualla, IH ;
Belev, B .
ENGINEERING STRUCTURES, 2002, 24 (03) :365-371
[30]   Seismic performance evaluation of a multi-slit damper [J].
Naeem, Asad ;
Kim, Jinkoo .
ENGINEERING STRUCTURES, 2019, 189 :332-346