Comparative Analysis of Procedural Outcomes and Complications Between De Novo and Upgraded Cardiac Resynchronization Therapy

被引:10
作者
Nemer, David M. [1 ]
Patel, Divyang R. [1 ]
Madden, Ruth A. [1 ]
Wilkoff, Bruce L. [1 ]
Rickard, John W. [1 ]
Tarakji, Khaldoun G. [1 ]
Varma, Niraj [1 ]
Hussein, Ayman A. [1 ]
Wazni, Oussama M. [1 ]
Kanj, Mohamed [1 ]
Baranowski, Bryan [1 ]
Cantillon, Daniel J. [1 ]
机构
[1] Cleveland Clin Fdn, Dept Cardiovasc Med, Sect Cardiac Pacing & Electrophysiol, 9500 Euclid Ave,Desk J2-2, Cleveland, OH 44195 USA
关键词
biventricular; CRT; stenosis; upgrade; venous; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; TRANSVENOUS LEAD EXTRACTION; HEART-FAILURE; PACEMAKER; PREDICTORS;
D O I
10.1016/j.jacep.2020.07.022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study compared rates of procedural success and complications between de novo cardiac resynchronization therapy (CRT) implantation versus upgrade, including characterization of technical challenges. BACKGROUND CRT upgrade is common, but data are limited on the incidence of procedural success and complications as compared to de novo implantation. METHODS All patients who underwent a transvenous CRT procedure at a single institution between 2013 and 2018 were reviewed for procedure outcome, 90-day complications, reasons for unsuccessful left ventricular lead delivery, and the presence of venous occlusive disease (VOD) that required a modified implantation technique. RESULTS Among 1,496 patients, 947 (63%) underwent de novo implantation and 549 (37%) underwent device upgrade. Patients who received a device upgrade were older (70 +/- 12 years vs. 68 +/- 13 years; p < 0.01), with a mate predominance (75% vs. 66%; p < 0.01) and greater prevalence of comorbidities. There was no difference in the rate of procedural success between de novo and upgrade CRT procedures (97% vs. 96%; p = 0.28) or 90-day complications (5.1% vs. 4.6%; p = 0.70). VOD was present in 23% of patients who received a device upgrade and was more common among patients with a dual-chamber versus a single-chamber device (26% vs. 9%; p < 0.001). Patients with and without VOD had a similar composite outcome of procedural failure or complication (8.0% vs. 7.8%; p = 1.0). CONCLUSIONS Rates of procedural success and complications were no different between de novo CRT implantations and upgrades. VOD frequently increased procedural complexity in upgrades, but alternative management strategies resulted in similar outcomes. Routine venography before CRT upgrade may aid in procedural planning and execution of these strategies. (C) 2021 by the American College of Cardiology Foundation.
引用
收藏
页码:62 / 72
页数:11
相关论文
共 30 条
[1]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[2]   Venous Stenosis After Transvenous Lead Placement: A Study of Outcomes and Risk Factors in 212 Consecutive Patients [J].
Abu-El-Haija, Basil ;
Bhave, Prashant D. ;
Campbell, Dwayne N. ;
Mazur, Alexander ;
Hodgson-Zingman, Denice M. ;
Cotarlan, Vlad ;
Giudici, Michael C. .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2015, 4 (08)
[3]   Transvenous lead extraction at the time of cardiac implantable electronic device upgrade: Complexity, safety, and outcomes [J].
Barakat, Amr F. ;
Wazni, Oussama M. ;
Tarakji, Khaldoun ;
Saliba, Walid I. ;
Nimri, Nayef ;
Rickard, John ;
Brunner, Michael ;
Bhargava, Mandeep ;
Kanj, Mohamed ;
Baranowski, Bryan ;
Martin, David O. ;
Cantillon, Daniel ;
Callahan, Thomas ;
Dresing, Thomas ;
Niebauer, Mark ;
Chung, Mina ;
Lindsay, Bruce D. ;
Wilkoff, Bruce ;
Hussein, Ayman A. .
HEART RHYTHM, 2017, 14 (12) :1807-1811
[4]   Use of a Lateral Infraclavicular Puncture to Obtain Proximal Venous Access with Occluded Subclavian/Axillary Venous Systems for Cardiac Rhythm Devices [J].
Bernstein, Neil E. ;
Aizer, Anthony ;
Chinitz, Larry A. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (08) :1017-1022
[5]   The European Cardiac Resynchronization Therapy Survey: comparison of outcomes between de novo cardiac resynchronization therapy implantations and upgrades [J].
Bogale, Nigussie ;
Witte, Klaus ;
Priori, Silvia ;
Cleland, John ;
Auricchio, Angelo ;
Gadler, Fredrik ;
Gitt, Anselm ;
Limbourg, Tobias ;
Linde, Cecilia ;
Dickstein, Kenneth .
EUROPEAN JOURNAL OF HEART FAILURE, 2011, 13 (09) :974-983
[6]   Recurrent Implantable Cardioverter-Defibrillator Replacement Is Associated with an Increasing Risk of Pocket-Related Complications [J].
Borleffs, C. Jan Willem ;
Thijssen, Joep ;
de Bie, Mihaly K. ;
van Rees, Johannes B. ;
van Welsenes, Guido H. ;
van Erven, Lieselot ;
Bax, Jeroen J. ;
Cannegieter, Suzanne C. ;
Schalij, Martin J. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (08) :1013-1019
[7]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[8]   Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. [J].
Cazeau, S ;
Leclercq, C ;
Lavergne, T ;
Walker, S ;
Varma, C ;
Linde, C ;
Garrigue, S ;
Kappenberger, L ;
Haywood, GA ;
Santini, M ;
Bailleul, C ;
Daubert, JC .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (12) :873-880
[9]   Trends and outcomes of cardiac resynchronization therapy upgrade procedures: A comparative analysis using a United States National Database 2003-2013 [J].
Cheung, Jim W. ;
Ip, James E. ;
Markowitz, Steven M. ;
Liu, Christopher F. ;
Thomas, George ;
Feldman, Dmitriy N. ;
Swaminathan, Rajesh V. ;
Lerman, Bruce B. ;
Kim, Luke K. .
HEART RHYTHM, 2017, 14 (07) :1043-1050
[10]   The effect of cardiac resynchronization on morbidity and mortality in heart failure [J].
Cleland, JGF ;
Daubert, J ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Tavazzi, L ;
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L ;
Poole-Wilson, PA ;
Rydén, L ;
Wedel, H ;
Wellens, HJJ ;
Uretsky, B ;
Thygesen, K ;
Böcker, D ;
Marijianowski, MMH ;
Freemantle, N ;
Calvert, MJ ;
Christ, G ;
Fruhwald, F ;
Hofmann, R ;
Krypta, A ;
Leisch, F ;
Pacher, R ;
Rauscha, F ;
Tavernier, R ;
Thomsen, PEB ;
Boesgaard, S ;
Eiskjær, H ;
Esperen, GT ;
Haarbo, J ;
Hagemann, A ;
Korup, E ;
Moller, M ;
Mortensen, P ;
Sogaard, P ;
Vesterlund, T ;
Huikuri, H ;
Niemelä, KI ;
Toivonen, L ;
Bauer, F ;
Cohen-Solal, A ;
Crocq, C ;
Djiane, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) :1539-1549