End-to-end validation of the geometric dose delivery performance of MR linac adaptive radiotherapy

被引:14
作者
Bernchou, Uffe [1 ,2 ]
Christiansen, Rasmus L. [1 ,2 ]
Bertelsen, Anders [1 ]
Tilly, David [4 ,5 ,6 ]
Riis, Hans L. [1 ,2 ]
Jensen, Henrik R. [1 ]
Mahmood, Faisal [1 ,2 ]
Hansen, Christian R. [1 ,2 ]
Hansen, Vibeke N. [1 ]
Schytte, Tine [3 ]
Brink, Carsten [1 ,2 ]
机构
[1] Odense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark
[2] Univ Southern Denmark, Dept Clin Res, Odense, Denmark
[3] Odense Univ Hosp, Dept Oncol, Odense, Denmark
[4] Uppsala Univ, Dept Immunol Genet & Pathol, Med Radiat Phys, Uppsala, Sweden
[5] Akad Hosp, Med Phys, Uppsala, Sweden
[6] Elekta Instruments AB, Stockholm, Sweden
关键词
end-to-end; MR-guided radiotherapy; radiochromic film; MR linac; adaptive radiotherapy; RADIATION-THERAPY; ACCELERATOR; FIELD; ACCURACY; SYSTEM;
D O I
10.1088/1361-6560/abd3ed
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The clinical introduction of hybrid magnetic resonance (MR) guided radiotherapy (RT) delivery systems has led to the need to validate the end-to-end dose delivery performance on such machines. In the current study, an MR visible phantom was developed and used to test the spatial deviation between planned and delivered dose at two 1.5 T MR linear accelerator (MR linac) systems, including pre-treatment imaging, dose planning, online imaging, image registration, plan adaptation, and dose delivery. The phantom consisted of 3D printed plastic and MR visible silicone rubber. It was designed to minimise air gaps close to the radiochromic film used as a dosimeter. Furthermore, the phantom was designed to allow submillimetre, reproducible positioning of the film in the phantom. At both MR linac systems, 54 complete adaptive, MR guided RT workflow sessions were performed. To test the dose delivery performance of the MR linac systems in various adaptive RT (ART) scenarios, the sessions comprised a range of systematic positional shifts of the phantom and imaging or plan adaptation conditions. In each workflow session, the positional translation between the film and the adaptive planned dose was determined. The results showed that the accuracy of the MR linac systems was between 0.1 and 0.9 mm depending on direction. The highest mean deviance observed was in the posterior-anterior direction, and the direction of the error was consistent between centres. The precision of the systems was related to whether the workflow utilized the internal image registration algorithm of the MR linac. Workflows using the internal registration algorithm led to a worse precision (0.2-0.7 mm) compared to workflows where the algorithm was decoupled (0.2 mm). In summary, the spatial deviation between planned and delivered dose of MR-guided ART at the two MR linac systems was well below 1 mm and thus acceptable for clinical use.
引用
收藏
页数:16
相关论文
共 35 条
[31]   An end-to-end examination of geometric accuracy of IGRT using a new digital accelerator equipped with onboard imaging system [J].
Wang, Lei ;
Kielar, Kayla N. ;
Mok, Ed ;
Hsu, Annie ;
Dieterich, Sonja ;
Xing, Lei .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (03) :757-769
[32]   European Association for Neuro-Oncology (EANO) guideline on the diagnosis and treatment of adult astrocytic and oligodendroglial gliomas [J].
Weller, Michael ;
van den Bent, Martin ;
Tonn, Jorg C. ;
Stupp, Roger ;
Preusser, Matthias ;
Cohen-Jonathan-Moyal, Elizabeth ;
Henriksson, Roger ;
Le Rhun, Emilie ;
Balana, Carmen ;
Chinot, Olivier ;
Bendszus, Martin ;
Reijneveld, Jaap C. ;
Dhermain, Frederick ;
French, Pim ;
Marosi, Christine ;
Watts, Colin ;
Oberg, Ingela ;
Pilkington, Geoffrey ;
Baumert, Brigitta G. ;
Taphoorn, Martin J. B. ;
Hegi, Monika ;
Westphal, Manfred ;
Reifenberger, Guido ;
Soffietti, Riccardo ;
Wick, Wolfgang .
LANCET ONCOLOGY, 2017, 18 (06) :E315-E329
[33]   Evaluation of a magnetic resonance guided linear accelerator for stereotactic radiosurgery treatment [J].
Wen, Ning ;
Kim, Joshua ;
Doemer, Anthony ;
Glide-Hurst, Carri ;
Chetty, Indrin J. ;
Liu, Chang ;
Laugeman, Eric ;
Xhaferllari, Ilma ;
Kumarasiri, Akila ;
Victoria, James ;
Bellon, Maria ;
Kalkanis, Steve ;
Siddiqui, M. Salim ;
Movsas, Benjamin .
RADIOTHERAPY AND ONCOLOGY, 2018, 127 (03) :460-466
[34]   Feasibility of stereotactic radiotherapy using a 1.5 T MR-linac: Multi-fraction treatment of pelvic lymph node oligometastases [J].
Werensteijn-Honingh, Anita M. ;
Kroon, Petra S. ;
Winkel, Dennis ;
Aalbers, Ellart M. ;
van Asselen, Bram ;
Bol, Gijsbert H. ;
Brown, Kevin J. ;
Eppinga, Wietse S. C. ;
van Es, Corine A. ;
Glitzner, Markus ;
de Groot-van Breugel, Eline N. ;
Hackett, Sara L. ;
Intven, Martijn ;
Kok, Jan G. M. ;
Kontaxis, Charis ;
Kotte, Alexis N. ;
Lagendijk, Jan J. W. ;
Philippens, Marielle E. P. ;
Tijssen, Rob H. N. ;
Wolthaus, Jochem W. H. ;
Woodings, Simon J. ;
Raaymakers, Bas W. ;
Jurgenliemk-Schulz, Ina M. .
RADIOTHERAPY AND ONCOLOGY, 2019, 134 :50-54
[35]   Adaptive radiotherapy: The Elekta Unity MR-linac concept [J].
Winkel, Dennis ;
Bol, Gijsbert H. ;
Kroon, Petra S. ;
van Asselen, Bram ;
Hackett, Sara S. ;
Werensteijn-Honingh, Anita M. ;
Intven, Martijn P. W. ;
Eppinga, Wietse S. C. ;
Tijssen, Rob H. N. ;
Kerkmeijer, Linda G. W. ;
de Boer, Hans C. J. ;
Mook, Stella ;
Meijer, Gert J. ;
Hes, Jochem ;
Willemsen-Bosman, Mirjam ;
de Groot-van Breugel, Eline N. ;
Jurgenliemk-Schulz, Ina M. ;
Raaymakers, Bas W. .
CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2019, 18 :54-59