Increased aortic compliance maintains left ventricular performance at lower energetic cost

被引:26
作者
Kolh, P [1 ]
D'Orio, V [1 ]
Lambermont, B [1 ]
Gerard, P [1 ]
Gommes, C [1 ]
Limet, R [1 ]
机构
[1] Univ Liege, Haemodynam Res Ctr, Liege, Belgium
关键词
aortic compliance; contractile function; hemodynamics; end-systolic elastance; pressure-volume area; pigs;
D O I
10.1016/S1010-7940(00)00341-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of this study was to investigate left ventricular contractility and energetic cost of cardiac ejection under conditions of acute increase in aortic compliance. Methods: In six anaesthetized pigs, ascending aortic compliance was increased by adding a volume chamber in parallel to the ascending aorta. Systemic vascular parameters, including characteristic impedance, peripheral resistance, total vascular compliance, and inertance, were estimated with a four-clement windkessel model. Arterial elastance was derived from these parameters. Left ventricular systolic function was assessed by end-systolic pressure-volume relationship tend-systolic elastance), and stroke work. Pressure-volume area was used as a measure of myocardial oxygen consumption. Heart rate remained constant during the experimentation. Results: Adding the aortic volume chamber significantly increased vascular compliance from 0.95 +/- 0.08 to 1.17 +/- 0.06 ml/ mmHg (P < 0.01), while inductance, characteristic impedance, peripheral resistance, and arterial elastance remained statistically at basal values, respectively 0.0020 +/- 0.0003 mmHg.s(2)/ml, 0.105 +/- 0.009 mmHg.s/ml, 1.27 +/- 0.12. mmHg.s/ml, and 2.43 +/- 0.21 mmHg/ml. During the same interval, stroke work and pressure-volume area decreased respectively from 2700 +/- 242 to 2256 +/- 75 mmHg.ml (P < 0.01), and from 3806 +/- 427 to 3179 +/- 167 mmHg.ml (P < 0.01). stroke work and pressure-volume area decreased at matched end-diastolic volumes. In contrast, end-systolic elastance, ejection fraction, and stroke volume remained statistically unchanged, respectively at 2.29 +/- 0.14 mmHg/ ml, 48.1 +/- 2.1 %, and 32.4 +/- 1.7 ml. Conclusions: These data suggest that, when facing an increased aortic compliance, the left ventricle displays unchanged contractility, bur the energetic cost of cardiac ejection is significantly decreased. These data may be of clinical importance when choosing an artificial prosthesis for ascending aortic replacement. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:272 / 278
页数:7
相关论文
共 20 条
  • [1] SENSITIVITY OF LEFT-VENTRICULAR END-SYSTOLIC PRESSURE-VOLUME RELATION TO TYPE OF LOADING INTERVENTION IN DOGS
    BAAN, J
    VANDERVELDE, ET
    [J]. CIRCULATION RESEARCH, 1988, 62 (06) : 1247 - 1258
  • [2] CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER
    BAAN, J
    VANDERVELDE, ET
    DEBRUIN, HG
    SMEENK, GJ
    KOOPS, J
    VANDIJK, AD
    TEMMERMAN, D
    SENDEN, J
    BUIS, B
    [J]. CIRCULATION, 1984, 70 (05) : 812 - 823
  • [3] CONTRACTILE STRENGTH AND MECHANICAL EFFICIENCY OF LEFT-VENTRICLE ARE ENHANCED BY PHYSIOLOGICAL AFTERLOAD
    BURKHOFF, D
    DETOMBE, PP
    HUNTER, WC
    KASS, DA
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1991, 260 (02): : H569 - H578
  • [4] Relationship between PVA and myocardial oxygen consumption can be derived from thermodynamics
    Denslow, S
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1996, 270 (02): : H730 - H740
  • [5] PRESSURE AND FLOW GENERATED BY LEFT VENTRICLE AGAINST DIFFERENT IMPEDANCES
    ELZINGA, G
    WESTERHOF, N
    [J]. CIRCULATION RESEARCH, 1973, 32 (02) : 178 - 186
  • [6] CHARACTERIZATION OF PULMONARY ARTERIAL INPUT IMPEDANCE WITH LUMPED PARAMETER MODELS
    GRANT, BJB
    PARADOWSKI, LJ
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (03): : H585 - H593
  • [7] EFFECT OF REDUCED AORTIC COMPLIANCE ON CARDIAC EFFICIENCY AND CONTRACTILE FUNCTION OF INSITU CANINE LEFT-VENTRICLE
    KELLY, RP
    TUNIN, R
    KASS, DA
    [J]. CIRCULATION RESEARCH, 1992, 71 (03) : 490 - 502
  • [8] Analysis of endotoxin effects on the intact pulmonary circulation
    Lambermont, B
    Kolh, P
    Detry, O
    Gerard, P
    Marcelle, P
    D'Orio, V
    [J]. CARDIOVASCULAR RESEARCH, 1999, 41 (01) : 275 - 281
  • [9] O'Rourke M.F., 1982, ARTERIAL FUNCTION HL
  • [10] SYSTEMIC COMPLIANCE - DOES IT PLAY A ROLE IN THE GENESIS OF ESSENTIAL-HYPERTENSION
    RANDALL, OS
    VANDENBOS, GC
    WESTERHOF, N
    POT, FOM
    [J]. CARDIOVASCULAR RESEARCH, 1984, 18 (08) : 455 - 462