Equivalence of Protein Inventories Obtained from Formalin-fixed Paraffin-embedded and Frozen Tissue in Multidimensional Liquid Chromatography-Tandem Mass Spectrometry Shotgun Proteomic Analysis

被引:165
作者
Sprung, Robert W., Jr. [1 ,2 ]
Brock, Jonathan W. C. [1 ,2 ]
Tanksley, Jarred P. [1 ]
Li, Ming [3 ]
Washington, Mary Kay [4 ]
Slebos, Robbert J. C. [1 ,5 ]
Liebler, Daniel C. [1 ,2 ]
机构
[1] Vanderbilt Univ, Sch Med, Jim Ayers Inst Precancer Detect & Diag, Vanderbilt Ingram Canc Ctr, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Sch Med, Dept Biochem, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Sch Med, Dept Biostat, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Sch Med, Dept Pathol, Nashville, TN 37232 USA
[5] Vanderbilt Univ, Sch Med, Dept Canc Biol, Nashville, TN 37232 USA
基金
美国国家卫生研究院;
关键词
ANTIGEN RETRIEVAL; CANCER-TISSUE; IDENTIFICATION; SECTIONS; PEPTIDE; EXTRACTION; SOFTWARE; CALCIUM; HEAT;
D O I
10.1074/mcp.M800518-MCP200
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Formalin-fixed paraffin-embedded (FFPE) tissue specimens comprise a potentially valuable resource for retrospective biomarker discovery studies, and recent work indicates the feasibility of using shotgun proteomics to characterize FFPE tissue proteins. A critical question in the field is whether proteomes characterized in FFPE specimens are equivalent to proteomes in corresponding fresh or frozen tissue specimens. Here we compared shotgun proteomic analyses of frozen and FFPE specimens prepared from the same colon adenoma tissues. Following deparaffinization, rehydration, and tryptic digestion under mild conditions, FFPE specimens corresponding to 200 mu g of protein yielded similar to 400 confident protein identifications in a one-dimensional reverse phase liquid chromatography-tandem mass spectrometry (LCMS/MS) analysis. The major difference between frozen and FFPE proteomes was a decrease in the proportions of lysine C-terminal to arginine C-terminal peptides observed, but these differences had little effect on the proteins identified. No covalent peptide modifications attributable to formaldehyde chemistry were detected by analyses of the MS/MS datasets, which suggests that undetected, cross-linked peptides comprise the major class of modifications in FFPE tissues. Fixation of tissue for up to 2 days in neutral buffered formalin did not adversely impact protein identifications. Analysis of archival colon adenoma FFPE specimens indicated equivalent numbers of MS/MS spectral counts and protein group identifications from specimens stored for 1, 3, 5, and 10 years. Combination of peptide isoelectric focusing-based separation with reverse phase LC-MS/MS identified 2554 protein groups in 600 ng of protein from frozen tissue and 2302 protein groups from FFPE tissue with at least two distinct peptide identifications per protein. Analysis of the combined frozen and FFPE data showed a 92% overlap in the protein groups identified. Comparison of gene ontology categories of identified proteins revealed no bias in protein identification based on subcellular localization. Although the status of posttranslational modifications was not examined in this study, archival samples displayed a modest increase in methionine oxidation, from similar to 17% after one year of storage to similar to 25% after 10 years. These data demonstrate the equivalence of proteome inventories obtained from FFPE and frozen tissue specimens and provide support for retrospective proteomic analysis of FFPE tissues for biomarker discovery. Molecular & Cellular Proteomics 8: 1988-1998, 2009.
引用
收藏
页码:1988 / 1998
页数:11
相关论文
共 32 条
[1]   CONTROLLING THE FALSE DISCOVERY RATE - A PRACTICAL AND POWERFUL APPROACH TO MULTIPLE TESTING [J].
BENJAMINI, Y ;
HOCHBERG, Y .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1995, 57 (01) :289-300
[2]   FURTHER-STUDIES IN THE VARIABILITY OF POCK COUNTS [J].
BRESLOW, N .
STATISTICS IN MEDICINE, 1990, 9 (06) :615-626
[3]  
Cargile Benjamin J, 2005, J Biomol Tech, V16, P181
[4]   Identification of proteins from formalin-fixed paraffin-embedded cells by LC-MS/MS [J].
Crockett, DK ;
Lin, ZS ;
Vaughn, CP ;
Lim, MS ;
Elenitoba-Johnson, KSJ .
LABORATORY INVESTIGATION, 2005, 85 (11) :1405-1415
[5]   Target-decoy search strategy for increased confidence in large-scale protein identifications by mass spectrometry [J].
Elias, Joshua E. ;
Gygi, Steven P. .
NATURE METHODS, 2007, 4 (03) :207-214
[6]   Pro-CrossLink. Software tool for protein cross-linking and mass spectrometry [J].
Gao, QX ;
Xue, S ;
Doneanu, CE ;
Shaffer, SA ;
Goodlett, DR ;
Nelson, SD .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2145-2149
[7]   Proteome analysis of microdissected formalin-fixed and paraffin-embedded tissue specimens [J].
Guo, Tong ;
Wang, Weijie ;
Rudnick, Paul A. ;
Song, Tao ;
Li, Jie ;
Zhuang, Zhengping ;
Weil, Robert J. ;
DeVoe, Don L. ;
Lee, Cheng S. ;
Balgley, Brian M. .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2007, 55 (07) :763-772
[8]   P-mod: An algorithm and software to map modifications to peptide sequences using tandem MS data [J].
Hansen, BT ;
Davey, SW ;
Ham, AJL ;
Liebler, DC .
JOURNAL OF PROTEOME RESEARCH, 2005, 4 (02) :358-368
[9]   Proteomic analysis of formalin-fixed prostate cancer tissue [J].
Hood, BL ;
Darfler, MM ;
Guiel, TG ;
Furusato, B ;
Lucas, DA ;
Ringeisen, BR ;
Sesterhenn, IA ;
Conrads, TP ;
Veenstra, TD ;
Krizman, DB .
MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (11) :1741-1753
[10]   Mass spectrometric analysis of formalin-fixed paraffin-embedded tissue: Unlocking the proteome within [J].
Hood, Brian L. ;
Conrads, Thomas P. ;
Veenstra, Timothy D. .
PROTEOMICS, 2006, 6 (14) :4106-4114