Simultaneous optical coherence tomography and Scheimpflug imaging using the same incident light

被引:10
作者
Li, Xiaoran [1 ]
Lawman, Samuel [1 ,2 ]
Williams, Bryan M. [2 ]
Ye, Sicong [1 ]
Shen, Yaochun [1 ]
Zheng, Yalin [2 ]
机构
[1] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
[2] Univ Liverpool, Dept Eye & Vis Sci, Liverpool L7 87X, Merseyside, England
基金
英国工程与自然科学研究理事会; 美国国家卫生研究院;
关键词
CENTRAL CORNEAL THICKNESS; REFRACTIVE-INDEX; DORZOLAMIDE HYDROCHLORIDE; IN-VIVO; OCT; MICROSCOPY; PENTACAM; HUMANS;
D O I
10.1364/OE.405643
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
For any single anterior chamber cross-sectional (tomographic) imaging method, there is a practical compromise between image size and image resolution. In order to obtain large field-of-view cross-sectional images of the whole anterior chamber and high-resolution cross-sectional images of the fine corneal layers, measurements by multiple devices are currently required. This paper presents a novel raster scanning tomographic imaging device that acquires simultaneous large field-of-view Scheimpflug (12.5 mm image depth, 50 mu m axial resolution in air) and high-resolution spectral domain optical coherence tomography (SD-OCT) (2 mm image depth, 3.7 mu m axial resolution in air) using the same illuminating photons. For the novel raster scanning 3D Scheimpflug imaging, a tunable lens system together with numerical methods for correcting refraction distortion were used. To demonstrate the capability of simultaneous measurement of both fine corneal layers and whole anterior chambers topology, ex vivo measurements on 12 porcine and 12 bovine eyes were carried out. There is a reasonable agreement in the overall central corneal thicknesses (CCT) obtained from the simultaneous SD-OCT and Scheimpflug measurements. In addition, because the same infrared light beam was used to illuminate the sample, both OCT and Scheimpflug images were taken at the exact same location of a sample simultaneously in a single measurement. This provides a unique method for measuring both the thickness and the refractive index of a sample. Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License.
引用
收藏
页码:39660 / 39676
页数:17
相关论文
共 41 条
[1]   Use of Ultra-High-Resolution Optical Coherence Tomography to Detect In Vivo Characteristics of Descemet's Membrane in Fuchs' Dystrophy [J].
Abou Shousha, Mohamed ;
Perez, Victor L. ;
Wang, Jianhua ;
Ide, Takeshi ;
Jiao, Shuliang ;
Chen, Qi ;
Chang, Victoria ;
Buchser, Nancy ;
Dubovy, Sander R. ;
Feuer, William ;
Yoo, Sonia H. .
OPHTHALMOLOGY, 2010, 117 (06) :1220-1227
[2]   Anterior segment optical coherence tomography [J].
Ang, Marcus ;
Baskaran, Mani ;
Werkmeister, Rene M. ;
Chua, Jacqueline ;
Schmidl, Doreen ;
dos Santos, Valentin Aranha ;
Garhoefer, Gerhard ;
Mehta, Jodhbir S. ;
Schmetterer, Leopold .
PROGRESS IN RETINAL AND EYE RESEARCH, 2018, 66 :132-156
[3]   Comparison between optical coherence tomography and fundus fluorescein angiography for the detection of cystoid macular edema in patients with uveitis [J].
Antcliff, RJ ;
Stanford, MR ;
Chauhan, DS ;
Graham, EM ;
Spalton, DJ ;
Shilling, JS ;
Ffytche, TJ ;
Marshall, J .
OPHTHALMOLOGY, 2000, 107 (03) :593-599
[4]   Dynamic Scheimpflug-based Assessment of Keratoconus and the Effects of Corneal Cross-linking [J].
Bak-Nielsen, Sashia ;
Pedersen, Iben B. ;
Ivarsen, Anders ;
Hjortdal, Jesper .
JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (06) :408-414
[5]   ADVANCED SLIT-IMAGE CAMERA [J].
BROWN, N .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1972, 56 (08) :624-&
[6]   The shape of the aging human lens: curvature, equivalent refractive index and the lens paradox [J].
Dubbelman, M ;
Van der Heijde, GL .
VISION RESEARCH, 2001, 41 (14) :1867-1877
[7]  
Faber C, 2008, SCAND J LAB ANIM SCI, V35, P39
[8]   The impact of Vision 2020 on global blindness [J].
Foster, A ;
Resnikoff, S .
EYE, 2005, 19 (10) :1133-1135
[9]   NONLINEAR REFRACTIVE-INDEX OF GLASS [J].
FOURNIER, JT ;
SNITZER, E .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1974, QE10 (05) :473-475
[10]  
Heichel Jens, 2016, Med Hypothesis Discov Innov Ophthalmol, V5, P125