Simulation and performance analysis of the perforated plate flowmeter for liquid hydrogen

被引:29
|
作者
Jin, Tao [1 ]
Tian, Hong [1 ]
Gao, Xu [2 ]
Liu, Yuanliang [1 ]
Wang, Jie [1 ]
Chen, Hong [2 ]
Lan, Yuqi [3 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Key Lab Refrigerat & Cryogen Technol Zhejiang Pro, Hangzhou 310027, Zhejiang, Peoples R China
[2] State Key Lab Technol Space Cryogen Propellants, Beijing 100028, Peoples R China
[3] Beijing Inst Aerosp Testing Technol, Beijing 100074, Peoples R China
关键词
Liquid hydrogen; Perforated plate; Flowmeter; DISCHARGE COEFFICIENTS; FLOW;
D O I
10.1016/j.ijhydene.2016.09.072
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The flow rate measurement of the liquid hydrogen (LH2) is of significance for the effective and safe operation of the systems dealing with massive liquid hydrogen, e.g., hydrogen stations and hydrogen fuelled space rockets. A perforated plate flowmeter is one of the effective devices for measuring flow rate accurately. In order to explore the optimal structure of a perforated plate flowmeter, the perforated plates with different perforating form, thickness, equivalent diameter ratio and hole diameter are numerically investigated with the help of ANSYS Fluent, mainly focusing on discharge coefficient C and pressure loss coefficient when applied to liquid hydrogen. The realizable kappa-epsilon model is adopted to describe the turbulence. Schnerr-Sauer cavitation model is employed for the case of cavitation to investigate the cavitation effect on the performance of the perforated plate. The simulation results reveal that the perforated plate with a larger center hole diameter is more suitable for measuring liquid hydrogen than that with the equal-aperture holes, especially for the case of the perforating form matching the turbulent velocity distribution in the circular tube. The equivalent diameter ratio is the dominant factor influencing the liquid hydrogen cavitation, and the reasonable increases of plate thickness and equivalent diameter ratio help to improve the performance of perforated plates applied to liquid hydrogen. (C) 2016 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:3890 / 3898
页数:9
相关论文
共 50 条
  • [1] Numerical study on performance of perforated plate applied to cryogenic fluid flowmeter
    Liu, Hai-fei
    Tian, Hong
    Chen, Hong
    Jin, Tao
    Tang, Ke
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2016, 17 (03): : 230 - 239
  • [2] Performance analysis of double-stage perforated plate flowmeter for cryogenic fluids
    Zhao, Feng
    Wei, Aibo
    Chen, Qiangfeng
    Song, Yucai
    Wu, Shuqin
    Zhang, Xiaobin
    CRYOGENICS, 2022, 124
  • [3] Design of Three-Dimensional Characteristics of Perforated Plate for Liquid Nitrogen Balanced Flowmeter
    Peng, Shiyao
    Zhao, Feng
    Liu, Luoqian
    Chai, Chong
    Zhang, Xiaobin
    ENERGIES, 2024, 17 (13)
  • [4] On the performance of perforated plate with optimized hole geometry
    Shaaban, S.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 46 : 44 - 50
  • [5] Design and optimization of a novel flowmeter for liquid hydrogen
    Shaaban, S.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (21) : 14621 - 14632
  • [6] A Numerical Investigation of Flow Characteristics in a Cryogenic Perforated Plate Flowmeter for Vertical Pipe Applications
    Tian, Yihan
    Zhang, Zhijian
    Gao, Zhaozhao
    Cui, Chen
    Chen, Liubiao
    Wang, Junjie
    ENERGIES, 2024, 17 (23)
  • [7] Simulation study on droplets removal performance of mist eliminator with perforated plate
    Luo G.
    Fang C.
    Zou R.
    Yao H.
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2020, 48 (04): : 1 - 6
  • [8] Simulation of Laminar Mixing in Fractal Perforated Plate Static Mixers
    Manshoor, B.
    Zaman, I.
    Ngali, Z.
    Khalid, A.
    MATERIALS, INDUSTRIAL, AND MANUFACTURING ENGINEERING RESEARCH ADVANCES 1.1, 2014, 845 : 31 - 35
  • [9] The numerical simulation of a rectifying device with a perforated plate
    Li, Di
    Zhang, Fagen
    Long, Jianyou
    Luo, Dinggui
    FLOW MEASUREMENT AND INSTRUMENTATION, 2014, 38 : 27 - 35
  • [10] CFD simulation design and optimization of a novel zigzag wave-plate mist eliminator with perforated plate
    Fang, Can
    Zou, Renjie
    Luo, Guangqian
    Ji, Qingyu
    Sun, Ruize
    Hu, Hongyun
    Li, Xian
    Yao, Hong
    APPLIED THERMAL ENGINEERING, 2021, 184