Uncertainty reduction in intensity modulated proton therapy by inverse Monte Carlo treatment planning

被引:7
|
作者
Moravek, Zdenek [1 ]
Rickhey, Mark [1 ]
Hartmann, Matthias [2 ]
Bogner, Ludwig [1 ]
机构
[1] Univ Hosp Regensburg, Dept Radiat Oncol, Regensburg, Germany
[2] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
关键词
DOSE CALCULATION; PHOTON BEAMS; OPTIMIZATION; RADIOTHERAPY; SENSITIVITY; ALGORITHM; IMRT;
D O I
10.1088/0031-9155/54/15/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Treatment plans for intensity-modulated proton therapy may be sensitive to some sources of uncertainty. One source is correlated with approximations of the algorithms applied in the treatment planning system and another one depends on how robust the optimization is with regard to intra-fractional tissue movements. The irradiated dose distribution may substantially deteriorate from the planning when systematic errors occur in the dose algorithm. This can influence proton ranges and lead to improper modeling of the Braggpeak degradation in heterogeneous structures or particle scatter or the nuclear interaction part. Additionally, systematic errors influence the optimization process, which leads to the convergence error. Uncertainties with regard to organ movements are related to the robustness of a chosen beam setup to tissue movements on irradiation. We present the inverse Monte Carlo treatment planning system IKO for protons (IKO-P), which tries to minimize the errors described above to a large extent. Additionally, robust planning is introduced by beam angle optimization according to an objective function penalizing paths representing strongly longitudinal and transversal tissue heterogeneities. The same score function is applied to optimize spot planning by the selection of a robust choice of spots. As spots can be positioned on different energy grids or on geometric grids with different space filling factors, a variety of grids were used to investigate the influence on the spot-weight distribution as a result of optimization. A tighter distribution of spot weights was assumed to result in a more robust plan with respect to movements. IKO-P is described in detail and demonstrated on a test case and a lung cancer case as well. Different options of spot planning and grid types are evaluated, yielding a superior plan quality with dose delivery to the spots from all beam directions over optimized beam directions. This option shows a tighter spot-weight distribution and should therefore be less sensitive to movements compared to optimized directions. But accepting a slight loss in plan quality, the latter choice could potentially improve robustness even further by accepting only spots from the most proper direction. The choice of a geometric grid instead of an energy grid for spot positioning has only a minor influence on the plan quality, at least for the investigated lung case.
引用
收藏
页码:4803 / 4819
页数:17
相关论文
共 50 条
  • [41] The effect of common dental fixtures on treatment planning and delivery for head and neck intensity modulated proton therapy
    Hu, Yue-Houng
    Seum, Wan Chan Tseung Hok
    Hunzeker, Ashley
    Muller, Olivia
    Foote, Robert L.
    Mundy, Daniel W.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (07):
  • [42] Intensity modulated proton therapy for postmastectomy radiation of bilateral implant reconstructed breasts: A treatment planning study
    Jimenez, Rachel B.
    Goma, Carles
    Nyamwanda, Jacqueline
    Kooy, Hanne M.
    Halabi, Tarek
    Napolitano, Brian N.
    McBride, Sean M.
    Taghian, Alphonse G.
    Lu, Hsiao-Ming
    MacDonald, Shannon M.
    RADIOTHERAPY AND ONCOLOGY, 2013, 107 (02) : 213 - 217
  • [43] Helical tomotherapy and intensity modulated proton therapy in the treatment of dominant intraprostatic lesion: A treament planning comparison
    Fellin, Francesco
    Azzeroni, Raffaella
    Maggio, Angelo
    Lorentini, Stefano
    Cozzarini, Cesare
    Di Muzio, Nadia
    Fiorino, Claudio
    Calandrino, Riccardo
    Schwarz, Marco
    RADIOTHERAPY AND ONCOLOGY, 2013, 107 (02) : 207 - 212
  • [44] Monte Carlo as a tool for treatment planning verification
    Sánchez-Doblado, F
    Leal, A
    Perucha, A
    Arráns, R
    Rincón, A
    Sánchez-Nieto, B
    Carrasco, E
    Roselló, J
    Errazquin, L
    Sánchez-Calzado, JA
    PHYSICA MEDICA, 2001, 17 : 84 - 86
  • [45] Robust treatment planning with conditional value at risk chance constraints in intensity- modulated proton therapy
    An, Yu
    Liang, Jianming
    Schild, Steven E.
    Bues, Martin
    Liu, Wei
    MEDICAL PHYSICS, 2017, 44 (01) : 28 - 36
  • [46] The rationale for intensity-modulated proton therapy in geometrically challenging cases
    Safai, S.
    Trofimov, A.
    Adams, J. A.
    Engelsman, M.
    Bortfeld, T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (18) : 6337 - 6353
  • [47] Robust beam orientation optimization for intensity-modulated proton therapy
    Gu, Wenbo
    Neph, Ryan
    Ruan, Dan
    Zou, Wei
    Dong, Lei
    Sheng, Ke
    MEDICAL PHYSICS, 2019, 46 (08) : 3356 - 3370
  • [48] Comparison of weekly and daily online adaptation for head and neck intensity-modulated proton therapy
    Bobic, Mislav
    Lalonde, Arthur
    Sharp, Gregory C.
    Grassberger, Clemens
    Verburg, Joost M.
    Winey, Brian A.
    Lomax, Antony J.
    Paganetti, Harald
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05)
  • [49] A generalized inverse planning tool for volumetric-modulated arc therapy
    Cao, Daliang
    Afghan, Muhammad K. N.
    Ye, Jinsong
    Chen, Fan
    Shepard, David M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (21) : 6725 - 6738
  • [50] A robust treatment planning approach for chest motion in postmastectomy chest wall intensity modulated radiation therapy
    Miyasaka, Yuya
    Ono, Takuya
    Chai, Hongbo
    Souda, Hikaru
    Lee, Sung Hyun
    Ishizawa, Miyu
    Akamatsu, Hiroko
    Sato, Hiraku
    Iwai, Takeo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (01):