Ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of Cr, Fe, Cu, Zn and Se in cereals

被引:13
|
作者
Huang, Shih-Yi [1 ]
Jiang, Shiuh-Jen [1 ,2 ]
Sahayam, A. C. [3 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 80424, Taiwan
[2] Kaohsiung Med Univ, Dept Med Lab Sci & Biotechnol, Kaohsiung 80708, Taiwan
[3] Natl Ctr Composit Characterisat Mat CCCM, Hyderabad, Andhra Pradesh, India
关键词
Inductively coupled plasma mass spectrometry; Dynamic reaction cell; Slurry sampling; Electrothermal vaporization; Cereal samples; DYNAMIC REACTION CELL; COAL FLY-ASH; ATOMIC-ABSORPTION-SPECTROMETRY; ICP-MS; BIOLOGICAL SAMPLES; ISOTOPIC DILUTION; LEAD; CADMIUM; MERCURY; PB;
D O I
10.1016/j.sab.2014.07.015
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry (USS-ETV-ICP-MS) has been applied to determine Cr, Fe, Cu, Zn and Se in several cereal samples. Thioacetamide was used as the modifier to enhance the ion signals. The background ions at the masses of interest were reduced in intensity significantly by using 1.0 mL min(-1) methane (CH4) as reaction cell gas in the dynamic reaction cell (DRC). Since the sensitivities of Cr, Fe, Cu, Zn and Se in different matrices were quite different, standard addition and isotope dilution methods were used for the determination of Cr, Fe, Cu, Zn and Se in these cereal samples. The method detection limits estimated from standard addition curves were about 1, 10, 4, 12 and 2 ng g(-1) for Cr, Fe, Cu, Zn and Se, respectively, in original cereal samples. This procedure has been applied to the determination of Cr, Fe, Cu, Zn and Se whose concentrations are in mu g g(-1) (except Cr and Se) in standard reference materials (SRM) of National institute of standards and technology (NIST), NIST SRM 1568a Rice Flour and NIST SRM 1567a Wheat Flour and two cereal samples purchased from a local market. The analysis results of reference materials agreed with certified values at 95% confidence level according to Student's T-test. The results for the real world cereal samples were also found to be in good agreement with the pneumatic nebulization DRC ICP-MS results of the sample solutions. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:46 / 50
页数:5
相关论文
共 50 条
  • [31] Fast and Sensitive Determination of Cadmium and Selenium in Rice by Direct Sampling Electrothermal Vaporization Inductively Coupled Plasma Mass Spectrometry
    Lan, Guanyu
    Li, Xue
    Jia, Hongyu
    Yu, Xiaofeng
    Wang, Zhaohui
    Yao, Jijun
    Mao, Xuefei
    MOLECULES, 2022, 27 (23):
  • [32] Solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry for the direct determination of Hg in sludge samples
    Vanhaecke, F
    Gelaude, I
    Moens, L
    Dams, R
    ANALYTICA CHIMICA ACTA, 1999, 383 (03) : 253 - 261
  • [33] Determination of trace impurities in high-purity quartz by electrothermal vaporization inductively coupled plasma mass spectrometry using the slurry sampling technique
    Hauptkorn, S
    Krivan, V
    Gercken, B
    Pavel, J
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) : 421 - 428
  • [34] Ultratrace determination of Pb, Se and As in wine samples by electrothermal vaporization inductively coupled plasma mass spectrometry
    Grindlay, Guillermo
    Mora, Juan
    Gras, Luis
    de Loos-Vollebregt, M. T. C.
    ANALYTICA CHIMICA ACTA, 2009, 652 (1-2) : 154 - 160
  • [35] Organic acids as the modifier to determine Zn, Cd, Tl and Pb in soil by slurry sampling electrothermal vaporization inductively-coupled plasma mass spectrometry
    Lu, HH
    Jiang, SJ
    ANALYTICA CHIMICA ACTA, 2001, 429 (02) : 247 - 255
  • [36] Determination of mercury and thallium in seawater by electrothermal vaporization inductively coupled plasma mass spectrometry
    Liu, HW
    Jiang, SJ
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2000, 47 (03) : 481 - 488
  • [37] A comparison of slurry sampling electrothermal vaporization and slurry nebulization inductively coupled plasma mass spectrometry for the direct determination of trace impurities in titanium dioxide powder
    Xiang, Guoqiang
    Hu, Bin
    Jiang, Zucheng
    Gong, Chuqing
    JOURNAL OF MASS SPECTROMETRY, 2006, 41 (10): : 1378 - 1385
  • [38] Determination of cadmium and lead in urine by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry
    Lee, KH
    Liu, SH
    Jiang, SJ
    ANALYST, 1998, 123 (07) : 1557 - 1560
  • [39] Determination of copper, cadmium and lead in biological samples by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry
    Chang, CC
    Jiang, SJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (01) : 75 - 80
  • [40] Cloud Point Extraction of Cr, Cu, Cd, and Pb From Water Samples and Determination by Electrothermal Vaporization Inductively Coupled Plasma Mass Spectrometry with Isotope Dilution
    Yi, Ya-Zih
    Wu, Sung-Yuan
    Jiang, Shiuh-Jen
    Sahayam, A. C.
    ATOMIC SPECTROSCOPY, 2013, 34 (02) : 39 - 47