Accuracy of tibial component positioning in the robotic arm assisted versus conventional unicompartmental knee arthroplasty

被引:8
作者
Thilak, Jai [1 ]
Thadi, Mohan [1 ]
Mane, Prajwal P. [1 ]
Sharma, Anubhav [1 ]
Mohan, Vipin [1 ]
Babu, Balu C. [1 ]
机构
[1] Amrita Inst Med Sci, Kochi 682041, Kerala, India
关键词
Unicompartmental; Partial knee arthroplasty; Robotic-assisted surgery; Osteoarthritis; Haptic guidance; COMPUTER NAVIGATION; EARLY FAILURE; REPLACEMENT; ALIGNMENT; IMPLANTATION; REVISION; PATIENT;
D O I
10.1016/j.jor.2020.08.022
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Our study aims to determine the planned accuracy of the tibial component placement in robotic arm assisted unicompartmental knee arthroplasty (UKA) versus the conventional jig based UKA of the initial cases done in India for the first time with this particular robotic system. Materials & Methods: Study group 1 consisted of patients who underwent robotic arm (MAKO, Stryker, USA) assisted UKA. Group 2 consists of patients who underwent a standard conventional jig based (Oxford knee, Biomet, UK). Post-operative radiographs were taken to determine the Tibial Implant position and orientation which were compared to their preoperative plan respectively by two independent observers. The mean error value was obtained for both study groups respectively and compared to determine the accuracy of the postoperative tibial implant placement. Results: In the Robotic arm assisted UKA, the deviation of post-operative varus angle from preoperative planned angle was about 0.43 degrees and post-operative Tibial slope alignment differed from preoperative plan was 0.41 degrees. In the Conventional UKA group post-operative varus angle differed from preoperative planned angle by about 2.12 degrees and post-operative Tibial slope alignment deviation from preoperative plan was 2.47 degrees. Conclusions: Robotic arm assisted system was more accurate compared to the conventional jig-based technique in achieving the planned orientation and alignment of the tibial implant in the initial learning phase of this particular Robotic System used for the first time in India. Mesh terms: partial knee replacement, robotic assisted surgery.
引用
收藏
页码:367 / 371
页数:5
相关论文
共 50 条
  • [31] Excellent early outcomes following lateral robotic-assisted unicompartmental knee arthroplasty
    Neitzke, Colin C.
    O'Donnell, Jeffrey A.
    Regis, Claude J.
    Bhatti, Pravjit
    Chiu, Yu-Fen
    Pearle, Andrew D.
    Mayman, David J.
    Chalmers, Brian P.
    KNEE, 2025, 54 : 50 - 57
  • [32] Does component placement affect short-term clinical outcome in robotic-arm assisted unicompartmental knee arthroplasty?
    Zambianchi, F.
    Franceschi, G.
    Rivi, E.
    Banchelli, F.
    Marcovigi, A.
    Nardacchione, R.
    Ensini, A.
    Catani, F.
    BONE & JOINT JOURNAL, 2019, 101B (04) : 435 - 442
  • [33] Short term outcomes following robotic arm-assisted lateral unicompartmental knee arthroplasty
    Wignadasan, Warran
    Chang, Justin
    Fontalis, Andreas
    Plastow, Ricci
    Haddad, Fares S.
    FRONTIERS IN SURGERY, 2023, 10
  • [34] Are there functional biomechanical differences in robotic arm-assisted bi-unicompartmental knee arthroplasty compared with conventional total knee arthroplasty? A prospective, randomized controlled trial
    Banger, M. S.
    Doonan, J.
    Jones, B. G.
    MacLean, A. D.
    Rowe, P. J.
    Blyth, M. J. G.
    BONE & JOINT JOURNAL, 2022, 104B (04) : 433 - 443
  • [35] Robotic-assisted unicompartmental knee replacement offers no early advantage over conventional unicompartmental knee replacement
    Wong, Jason
    Murtaugh, Taylor
    Lakra, Akshay
    Cooper, H. John
    Shah, Roshan P.
    Geller, Jeffrey A.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (07) : 2303 - 2308
  • [36] Robotic arm-assisted versus conventional medial unicompartmental knee arthroplasty: five-year clinical outcomes of a randomized controlled trial
    Banger, M.
    Doonan, J.
    Rowe, P.
    Jones, B.
    MacLean, A.
    Blyth, M. J. B.
    BONE & JOINT JOURNAL, 2021, 103B (06) : 1088 - 1095
  • [37] Varus placement of the tibial component of Oxford unicompartmental knee arthroplasty decreases the risk of postoperative tibial fracture
    Suda, Y.
    Hiranaka, T.
    Kamenaga, T.
    Koide, M.
    Fujishiro, T.
    Okamoto, K.
    Matsumoto, T.
    BONE & JOINT JOURNAL, 2022, 104B (10) : 1118 - 1125
  • [38] Improved positioning of the tibial component in unicompartmental knee arthroplasty with patient-specific cutting blocks
    M. L. Dao Trong
    C. Diezi
    G. Goerres
    N. Helmy
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 1993 - 1998
  • [39] Adequate Positioning of the Tibial Component Is Key to Avoiding Bearing Impingement in Oxford Unicompartmental Knee Arthroplasty
    Kamenaga, Tomoyuki
    Hiranaka, Takafumi
    Takayama, Koji
    Tsubosaka, Masanori
    Kuroda, Ryosuke
    Matsumoto, Tomoyuki
    JOURNAL OF ARTHROPLASTY, 2019, 34 (11) : 2606 - 2613
  • [40] Tibial component alignment and risk of loosening in unicompartmental knee arthroplasty: a radiographic and radiostereometric study
    Barbadoro, P.
    Ensini, A.
    Leardini, A.
    d'Amato, M.
    Feliciangeli, A.
    Timoncini, A.
    Amadei, F.
    Belvedere, C.
    Giannini, S.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 3157 - 3162