Background: Our study aims to determine the planned accuracy of the tibial component placement in robotic arm assisted unicompartmental knee arthroplasty (UKA) versus the conventional jig based UKA of the initial cases done in India for the first time with this particular robotic system. Materials & Methods: Study group 1 consisted of patients who underwent robotic arm (MAKO, Stryker, USA) assisted UKA. Group 2 consists of patients who underwent a standard conventional jig based (Oxford knee, Biomet, UK). Post-operative radiographs were taken to determine the Tibial Implant position and orientation which were compared to their preoperative plan respectively by two independent observers. The mean error value was obtained for both study groups respectively and compared to determine the accuracy of the postoperative tibial implant placement. Results: In the Robotic arm assisted UKA, the deviation of post-operative varus angle from preoperative planned angle was about 0.43 degrees and post-operative Tibial slope alignment differed from preoperative plan was 0.41 degrees. In the Conventional UKA group post-operative varus angle differed from preoperative planned angle by about 2.12 degrees and post-operative Tibial slope alignment deviation from preoperative plan was 2.47 degrees. Conclusions: Robotic arm assisted system was more accurate compared to the conventional jig-based technique in achieving the planned orientation and alignment of the tibial implant in the initial learning phase of this particular Robotic System used for the first time in India. Mesh terms: partial knee replacement, robotic assisted surgery.
引用
收藏
页码:367 / 371
页数:5
相关论文
共 50 条
  • [1] Improved Accuracy of Component Positioning with Robotic-Assisted Unicompartmental Knee Arthroplasty
    Bell, Stuart W.
    Anthony, Iain
    Jones, Bryn
    MacLean, Angus
    Rowe, Philip
    Blyth, Mark
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (08) : 627 - 635
  • [2] Robotic arm-assisted versus conventional unicompartmental knee arthroplasty EXPLORATORY SECONDARY ANALYSIS OF A RANDOMISED CONTROLLED TRIAL
    Blyth, M. J. G.
    Anthony, I.
    Rowe, P.
    Banger, M. S.
    MacLean, A.
    Jones, B.
    BONE & JOINT RESEARCH, 2017, 6 (11): : 631 - 639
  • [3] Robotic arm-assisted vs conventional unicompartmental knee arthroplasty A meta-analysis of the effects on clinical outcomes
    Zhang, Fengjun
    Li, Hongcai
    Ba, Zhaochen
    Bo, Chunguang
    Li, Kai
    MEDICINE, 2019, 98 (35) : e16968
  • [4] Robotic arm- assisted conversion of unicompartmental knee arthroplasty to total knee arthroplasty
    Mancino, F.
    Fontalis, A.
    Grandhi, T. S. P.
    Magan, A.
    Plastow, R.
    Kayani, B.
    Haddad, F. S.
    BONE & JOINT JOURNAL, 2024, 106B (07) : 680 - 687
  • [5] Revision Analysis of Robotic Arm-Assisted and Manual Unicompartmental Knee Arthroplasty
    Cool, Christina L.
    Needham, Keith A.
    Khlopas, Anton
    Mont, Michael A.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (05) : 926 - 931
  • [6] Obliquity of tibial component after unicompartmental knee arthroplasty
    Asada, Shigeki
    Inoue, Shinji
    Tsukamoto, Ichiro
    Mori, Shigeshi
    Akagi, Masao
    KNEE, 2019, 26 (02) : 410 - 415
  • [7] Unicompartmental knee arthroplasty: Is robotic technology more accurate than conventional technique?
    Citak, Mustafa
    Suero, Eduardo M.
    Citak, Musa
    Dunbar, Nicholas J.
    Branch, Sharon H.
    Conditt, Michael A.
    Banks, Scott A.
    Pearle, Andrew D.
    KNEE, 2013, 20 (04) : 268 - 271
  • [8] Minimally Invasive Robotic-Arm-Guided Unicompartmental Knee Arthroplasty
    Conditt, Michael A.
    Roche, Martin W.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A : 63 - 68
  • [9] Radiological outcomes following manual and robotic-assisted unicompartmental knee arthroplasty
    Kazarian, G. S.
    Barrack, R. L.
    Barrack, T. N.
    Lawrie, C. M.
    Nunley, R. M.
    BONE & JOINT OPEN, 2021, 2 (03): : 191 - 197
  • [10] Robotic-arm-assisted conversion of unicompartmental knee arthroplasty to total knee arthroplasty
    Magruder, Matthew L.
    Mcclure, Tanner
    Marchand, Kevin
    Mont, Michael A.
    Marchand, Robert C.
    JOURNAL OF ORTHOPAEDICS, 2024, 52 : 119 - 123