Characterisation of density distributions in roller-compacted ribbons using micro-indentation and X-ray micro-computed tomography

被引:86
|
作者
Miguelez-Moran, Andres M. [1 ,2 ]
Wu, Chuan-Yu [1 ]
Dong, Hanshan [3 ]
Seville, Jonathan P. K. [4 ]
机构
[1] Univ Birmingham, Sch Chem Engn, Birmingham B15 2TT, W Midlands, England
[2] Heidelberg Univ, Sch Pharmaceut Technol & Biopharm, Heidelberg, Germany
[3] Univ Birmingham, Sch Met & Mat, Birmingham B15 2TT, W Midlands, England
[4] Univ Warwick, Sch Engn, Coventry CV4 7AL, W Midlands, England
基金
英国工程与自然科学研究理事会;
关键词
Roller compaction; Granulation; Agglomeration; Micro-indentation; X-ray tomography; Density distribution; Ribbon; COMPACTION/DRY GRANULATION; TENSILE-STRENGTH; FORCE; BEHAVIOR; POWDERS;
D O I
10.1016/j.ejpb.2008.12.005
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Roller compaction is one stage in a dry granulation process to produce free flowing granules. Its proper understanding is essential in optimising manufacturing efficiency and product quality. Roller compaction produces a compacted strip or "ribbon", which is then milled to produce granules. For a given milling condition, the density distribution in the ribbons determines the properties of the granules (particularly their size distribution and strength). Therefore, knowing the density distributions in the ribbons is very important in improving the effectiveness of the roller compaction process and the quality of the granules produced. In this paper, the density distribution in roller-compacted ribbons of microcrystalline cellulose (Avicel PH102) has been examined using three different techniques: (1) sectioning; (2) micro-indentation and (3) X-ray micro-computed tomography. It has been shown that with proper calibration all three techniques can essentially produce the same results, but with a different degree of resolution (scale of scrutiny). In addition, the influence of process conditions, such as roll gap, roll speed and the presence or absence of lubrication, on the ribbon density distributions has also been investigated. Flow into the press is often constrained by the presence of "cheek plates", which prevent lateral powder movement. In this type of arrangement, it is found that non-uniform powder feeding occurs in the compaction region, induced by the friction between the powder and the cheek plates: as a result, the densities in the middle of the ribbon width are generally higher than those close to the edges. It has also been shown that higher average ribbon densities are obtained when the roll gap, roll speed, or the friction between the powder and the side cheek plates is reduced. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:173 / 182
页数:10
相关论文
共 50 条
  • [1] A Quantitative Correlation of the Effect of Density Distributions in Roller-Compacted Ribbons on the Mechanical Properties of Tablets Using Ultrasonics and X-ray Tomography
    Ilgaz Akseli
    Srinivas Iyer
    Hwahsiung P. Lee
    Alberto M. Cuitiño
    AAPS PharmSciTech, 2011, 12 : 834 - 853
  • [2] A Quantitative Correlation of the Effect of Density Distributions in Roller-Compacted Ribbons on the Mechanical Properties of Tablets Using Ultrasonics and X-ray Tomography
    Akseli, Ilgaz
    Iyer, Srinivas
    Lee, Hwahsiung P.
    Cuitino, Alberto M.
    AAPS PHARMSCITECH, 2011, 12 (03): : 834 - 853
  • [3] Determining influence of impressed current density on current efficiency with X-ray micro-computed tomography
    Hong, Shuxian
    Zheng, Fan
    Shi, Guiyun
    Dong, Biqin
    Liu, Min
    Tang, Luping
    Zhang, Yuxin
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 246 (246)
  • [4] Insight into tableted pellets by combining X-ray micro-computed tomography and experimental compaction
    Boudina, Imen
    Rondet, Eric
    Nezamabadi, Saeid
    Sharkawi, Tahmer
    POWDER TECHNOLOGY, 2022, 397
  • [5] Characterisation of damage evolution in plain weave SiC/SiC composites using in situ X-ray micro-computed tomography
    Zhang, Daxu
    Liu, Yu
    Liu, Hailong
    Feng, Yuqi
    Guo, Hongbao
    Hong, Zhiliang
    Chen, Chao
    Zhang, Yi
    COMPOSITE STRUCTURES, 2021, 275
  • [6] X-ray micro-computed tomography (CT): an emerging opportunity in parasite imaging
    O'Sullivan, James D. B.
    Behnsen, Julia
    Starborg, Tobias
    MacDonald, Andrew S.
    Phythian-Adams, Alexander T.
    Else, Kathryn J.
    Cruickshank, Sheena M.
    Withers, Philip J.
    PARASITOLOGY, 2018, 145 (07) : 848 - 854
  • [7] Application of the X-ray micro-computed tomography to the analysis of the structure of polymeric materials
    Szewczykowski, Piotr P.
    Skarzynski, Lukasz
    POLIMERY, 2019, 64 (01) : 12 - 22
  • [8] Laboratory x-ray micro-computed tomography: a user guideline for biological samples
    du Plessis, Anton
    Broeckhoven, Chris
    Guelpa, Anina
    le Roux, Stephan Gerhard
    GIGASCIENCE, 2017, 6 (06):
  • [9] Laboratory apparatus for in-situ corrosion fatigue testing and characterisation of fatigue cracks using X-ray micro-computed tomography
    Farhad, F.
    Smyth-Boyle, D.
    Zhang, X.
    Wallis, I.
    Panggabean, D.
    FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2018, 41 (12) : 2629 - 2637
  • [10] X-ray micro-computed tomography of postmortem brain tissue using potassium dichromate as a contrast agent
    Herrera, M.
    Notario, B.
    Barrio, M. C.
    Metscher, B. D.
    Murillo Gonzalez, J.
    ARCHIVES ITALIENNES DE BIOLOGIE, 2018, 156 (1-2): : 48 - 53