Albert-Lembert versus hybrid-layered suture in hand sewn end-to-end cervical esophagogastric anastomosis after esophageal squamous cell carcinoma resection

被引:7
作者
Feng, Fan [1 ]
Sun, Li [1 ]
Xu, Guanghui [1 ]
Hong, Liu [1 ]
Yang, Jianjun [1 ]
Cai, Lei [1 ]
Li, Guocai [1 ]
Guo, Man [1 ]
Lian, Xiao [1 ]
Zhang, Hongwei [1 ]
机构
[1] Fourth Mil Med Univ, Xijing Hosp, Dept Digest Surg, Xian 710032, Peoples R China
关键词
Hand sewn anastomosis; end-to-end anastomosis; cervical esophagogastric anastomosis (CEGA); esophageal squamous cell carcinoma (ESCC); esophagectomy; MINIMALLY INVASIVE ESOPHAGECTOMY; RISK-FACTORS; CANCER RESECTION; GASTRIC TUBE; COMPLICATIONS; STRICTURE; OUTCOMES; STOMACH; LEAKS;
D O I
10.3978/j.issn.2072-1439.2015.11.09
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Hand sewn cervical esophagogastric anastomosis (CEGA) is regarded as preferred technique by surgeons after esophagectomy. However, considering the anastomotic leakage and stricture, the optimal technique for performing this anastomosis is still under debate. Methods: Between November 2010 and September 2012, 230 patients who underwent esophagectomy with hand sewn end-to-end (ETE) CEGA for esophageal squamous cell carcinoma (ESCC) were analyzed retrospectively, including 111 patients underwent Albert-Lembert suture anastomosis and 119 patients underwent hybrid-layered suture anastomosis. Anastomosis construction time was recorded during operation. Anastomotic leakage was recorded through upper gastrointestinal water-soluble contrast examination. Anastomotic stricture was recorded during follow up. Results: The hybrid-layered suture was faster than Albert-Lembert suture (29.40 +/- 1.24 min vs. 33.83 +/- 1.41 min, P=0.02). The overall anastomotic leak rate was 7.82%, the leak rate in hybrid-layered suture group was significantly lower than that in Albert-Lembert suture group (3.36% vs. 12.61%, P=0.01). The overall anastomotic stricture rate was 9.13%, the stricture rate in hybrid-layered suture group was significantly lower than that in Albert-Lembert suture group (5.04% vs. 13.51%, P=0.04). Conclusions: Hand sewn ETE CEGA with hybrid-layered suture is associated with lower anastomotic leakage and stricture rate compared to hand sewn ETE CEGA with Albert-Lembert suture.
引用
收藏
页码:1917 / 1926
页数:10
相关论文
共 35 条
[21]   Colon Interposition After Esophagectomy With Extended Lymphadenectomy for Esophageal Cancer [J].
Mine, Shinji ;
Udagawa, Harushi ;
Tsutsumi, Kenji ;
Kinoshita, Yoshihiro ;
Ueno, Masaki ;
Ehara, Kazuhisa ;
Haruta, Syusuke .
ANNALS OF THORACIC SURGERY, 2009, 88 (05) :1647-1654
[22]  
Murr M, 2003, J GASTROINTEST SURG, V7, P1002
[23]   Arteriography of three models of gastric oesophagoplasty: the whole stomach, a wide gastric tube and a narrow gastric tube [J].
Ndoye, Jean-Marc ;
Dia, Abdarahmane ;
Ndiaye, Assane ;
Fall, Babacar ;
Diop, Mamadou ;
Ndiaye, Abdoulaye ;
Sow, Moussa Lamine .
SURGICAL AND RADIOLOGIC ANATOMY, 2006, 28 (05) :429-437
[24]   End-to-End Versus End-to-Side Esophagogastrostomy After Esophageal Cancer Resection A Prospective Randomized Study [J].
Nederlof, Nina ;
Tilanus, Hugo W. ;
Tran, T. C. Khe ;
Hop, Wim C. J. ;
Wijnhoven, Bas P. L. ;
de Jonge, Jeroen .
ANNALS OF SURGERY, 2011, 254 (02) :226-233
[25]   Management of Gastrointestinal Leaks After Minimally Invasive Esophagectomy: Conventional Treatments vs. Endoscopic Stenting [J].
Nguyen, Ninh T. ;
Rudersdorf, Patrick Donohue ;
Smith, Brian R. ;
Reavis, Kevin ;
Nguyen, Xuan-Mai T. ;
Stamos, Michael J. .
JOURNAL OF GASTROINTESTINAL SURGERY, 2011, 15 (11) :1952-1960
[26]   Incidence and outcome of anastomotic stricture after laparoscopic gastric bypass [J].
Nguyen, NT ;
Stevens, CM ;
Wolfe, BM .
JOURNAL OF GASTROINTESTINAL SURGERY, 2003, 7 (08) :997-1002
[27]   Eliminating the cervical esophagogastric anastomotic leak with a side-to-side stapled anastomosis [J].
Orringer, MB ;
Marshall, B ;
Iannettoni, MD .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 119 (02) :277-287
[28]  
Peters J, 2005, J GASTROINTEST SURG, V9, P1040
[29]   Randomized Trial Comparing Side-to-Side Stapled and Hand-Sewn Esophagogastric Anastomosis in Neck [J].
Saluja, Sundeep Singh ;
Ray, Sukanta ;
Pal, Sujoy ;
Sanyal, Sumit ;
Agrawal, Nikhil ;
Dash, Nihar Ranjan ;
Sahni, Peush ;
Chattopadhyay, Tushar Kanti .
JOURNAL OF GASTROINTESTINAL SURGERY, 2012, 16 (07) :1287-1295
[30]   Incidence and risk factors predisposing anastomotic leak after transhiatal esophagectomy [J].
Tabatabai, Abbas ;
Hashemi, Mozaffar ;
Mohajeri, Gholamreza ;
Ahmadinejad, Mojtaba ;
Khan, Ishfaq Abass ;
Haghdani, Saeid .
ANNALS OF THORACIC MEDICINE, 2009, 4 (04) :197-200