Effective radiation dose and eye lens dose in dental cone beam CT: effect of field of view and angle of rotation

被引:64
作者
Pauwels, R. [1 ,2 ]
Zhang, G. [3 ]
Theodorakou, C. [4 ]
Walker, A. [4 ]
Bosmans, H. [3 ]
Jacobs, R. [1 ]
Bogaerts, R. [5 ]
Horner, K. [6 ]
机构
[1] Katholieke Univ Leuven, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Oral Imaging Ctr,Fac Med, Leuven, Belgium
[2] Chulalongkorn Univ, Dept Radiol, Fac Dent, Bangkok, Thailand
[3] Univ Hosp Leuven, Dept Radiol, Leuven, Belgium
[4] Christie Hosp NHS Fdn Trust, Manchester Acad Hlth Sci Ctr, Christie Med Phys & Engn, Manchester, Lancs, England
[5] Univ Hosp Leuven, Dept Expt Radiotherapy, Leuven, Belgium
[6] Univ Manchester, Manchester Acad Hlth Sci Ctr, Sch Dent, Manchester, Lancs, England
关键词
COMPUTED-TOMOGRAPHY; IMAGE QUALITY; CBCT DEVICES; DOSIMETRY; REDUCTION; RADIOLOGY; SCANNERS; ORGAN;
D O I
10.1259/bjr.20130654
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To quantify the effect of field of view (FOV) and angle of rotation on radiation dose in dental cone beam CT (CBCT) and to define a preliminary volume-dose model. Methods: Organ and effective doses were estimated using 148 thermoluminescent dosemeters placed in an anthropomorphic phantom. Dose measurements were undertaken on a 3D Accuitomo 170 dental CBCT unit (J. Morita, Kyoto, Japan) using six FOVs as well as full-rotation (360 degrees) and half-rotation (180 degrees) protocols. Results: For the 360 degrees rotation protocols, effective dose ranged between 54 mu Sv (4 x 4 cm, upper canine) and 303 mu(17 x 12 cm, maxillofacial). An empirical relationship between FOV dimension and effective dose was derived. The use of a 180 degrees rotation resulted in an average dose reduction of 45% compared with a 360 degrees rotation. Eye lens doses ranged between 95 and 6861 mu Gy. Conclusion: Significant dose reduction can be achieved by reducing the FOV size, particularly the FOV height, of CBCT examinations to the actual region of interest. In some cases, a 180 degrees rotation can be preferred, as it has the added value of reducing the scan time. Eye lens doses should be reduced by decreasing the height of the FOV rather than using inferior FOV positioning, as the latter would increase the effective dose considerably. Advances in knowledge: The effect of the FOV and rotation angle on the effective dose in dental CBCT was quantified. The dominant effect of FOV height was demonstrated. A preliminary model has been proposed, which could be used to predict effective dose as a function of FOV size and position.
引用
收藏
页数:9
相关论文
共 34 条
  • [1] Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography
    Chau, Anson C. M.
    Fung, Karl
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (04): : 559 - 565
  • [2] Effective doses from cone beam CT investigation of the jaws
    Davies, J.
    Johnson, B.
    Drage, N. A.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (01) : 30 - 36
  • [3] Cone-beam computed tomography for routine orthodontic treatment planning: A radiation dose evaluation
    Garcia Silva, Maria Alves
    Wolf, Ulrich
    Heinicke, Frank
    Bumann, Axel
    Visser, Heiko
    Hirsch, Edgar
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (05) : 640.e1 - 640.e5
  • [4] Effect of leaded glasses and thyroid shielding on cone beam CT radiation dose in an adult female phantom
    Goren, A. D.
    Prins, R. D.
    Dauer, L. T.
    Quinn, B.
    Al-Najjar, A.
    Faber, R. D.
    Patchell, G.
    Branets, I.
    Colosi, D. C.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (06)
  • [5] Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view
    Hirsch, E.
    Wolf, U.
    Heinicke, F.
    Silva, M. A. G.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (05) : 268 - 273
  • [6] Basic principles for use of dental cone beam computed tomography: consensus guidelines of the European Academy of Dental and Maxillofacial Radiology
    Horner, K.
    Islam, M.
    Flygare, L.
    Tsiklakis, K.
    Whaites, E.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (04) : 187 - 195
  • [7] HUDA W, 1984, HEALTH PHYS, V47, P463
  • [8] International Commission on Radiation Units and Measurements, 1989, TISS SUBST RAD DOS M
  • [9] Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT
    Jeong, Dae-Kyo
    Lee, Sang-Chul
    Huh, Kyung-Hoe
    Yi, Won-Jin
    Heo, Min-Suk
    Lee, Sam-Sun
    Choi, Soon-Chul
    [J]. IMAGING SCIENCE IN DENTISTRY, 2012, 42 (02) : 65 - 70
  • [10] Assessment of radiation exposure in dental cone-beam computerized tomography with the use of metal-oxide semiconductor field-effect transistor (MOSFET) dosimeters and Monte Carlo simulations
    Koivisto, J.
    Kiljunen, T.
    Tapiovaara, M.
    Wolff, J.
    Kortesniemi, M.
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 114 (03): : 393 - 400