One thousand consecutive IntraLase laser in situ keratomileusis flaps

被引:155
作者
Binder, Perry S. [1 ]
机构
[1] Gordon Binder & Weiss Vis Inst, San Diego, CA USA
关键词
D O I
10.1016/j.jcrs.2006.02.043
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To measure laser in situ keratomileusis (LASIK) flap dimensions created with the IntraLase FS (IL) laser (Intralase Corporation). SETTING: Private practice, San Diego, California, USA. METHODS: Consecutive LASIK flaps created with the IL were measured with subtraction ultrasound at primary and enhancement surgeries. Data were stored in Outcomes Analysis Software and analyzed using MS Excel (Microsoft Corporation) and SSPS software. RESULTS: The mean achieved flap thickness exceeded the attempted by 9.4 to 34.3 mu m. The standard deviation varied from +/- 10.2 to +/- 21.7 mu m. Preoperative corneal thickness and power did not affect achieved flap thickness. Seventy-three percent of mate eye flaps were within +/- 15 mu m of each other for the 90 mu m attempted. The same flaps measured at enhancement were thicker than the primarily measured flaps (n = 58). Diffuse lamellar keratitis and slipped flaps were eliminated with experience. There were no decentered or irregular flaps, epithelial defects, or flap perforations. CONCLUSIONS: Compared with published results of mechanical microkeratomes, the IL reduced the standard deviation of flap thickness as well as the achieved range. It eliminated physical complications associated with mechanical flap creation, and the impact of preoperative pachymetry and corneal power, thereby permitting more myopia to be corrected without risking deep ablations.
引用
收藏
页码:962 / 969
页数:8
相关论文
共 30 条
[1]  
Arbelaez MC, 2002, J REFRACT SURG, V18, pS357
[2]  
Behrens A, 1999, J REFRACT SURG, V15, P118
[3]   Experimental evaluation of two current-generation automated microkeratomes: The Hansatome and the Supratome [J].
Behrens, A ;
Langenbucher, A ;
Kus, MM ;
Rummelt, C ;
Seitz, B .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (01) :59-67
[4]   Ectasia after laser in situ keratomileusis [J].
Binder, PS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (12) :2419-2429
[5]   Flap dimensions created with the IntraLase FS laser [J].
Binder, PS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (01) :26-32
[6]   REFRACTIVE KERATOPLASTY - MICROKERATOME EVALUATION [J].
BINDER, PS ;
AKERS, PH ;
DEG, JK ;
ZAVALA, EY .
ARCHIVES OF OPHTHALMOLOGY, 1982, 100 (05) :802-806
[7]  
Binder PS, 1997, J REFRACT SURG, V13, P142
[8]  
Binder PS, 1999, OPHTHALMIC PRACT, V17, P308
[9]   The architecture of the corneal stroma [J].
Bron, AJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (04) :379-381
[10]   Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome [J].
Cheng, ACK ;
Rao, SK ;
Yu, EYW ;
Leung, HTC ;
Law, RWK ;
Lam, DSC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (11) :1712-1712