The biomechanics of the T2 femoral nailing system: a comparison of synthetic femurs with finite element analysis

被引:41
作者
Bougherara, H. [1 ]
Zdero, R. [2 ]
Miric, M. [1 ]
Shah, S. [2 ]
Hardisty, M. [3 ]
Zalzal, P. [4 ]
Schemitsch, E. H. [5 ]
机构
[1] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON, Canada
[2] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
[3] Sunnybrook Hlth Sci Ctr, Orthoped Biomech Lab, Toronto, ON M4N 3M5, Canada
[4] McMaster Univ, Dept Surg, Hamilton, ON L8S 4L8, Canada
[5] Univ Toronto, Dept Surg, Toronto, ON, Canada
关键词
biomechanics; finite element; nail; femur; MECHANICAL VALIDATION; INTRAMEDULLARY NAIL; SHAFT FRACTURES; BONE; DEFORMITY; FIXATION; LOCKING; DESIGN;
D O I
10.1243/09544119JEIM501
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intramedullary nails are commonly used to repair femoral fractures. Fractures in normal healthy bone often occur in the young during motor vehicle accidents. Although clinically beneficial, bone refracture and implant failure persist. Large variations in human femur quality and geometry have motivated recent experimental use of synthetic femurs that mimic human tissue and the development of increasingly sophisticated theoretical models. Four synthetic femurs were fitted with a T2 femoral nailing system (Stryker, Mahwah, New Jersey, USA). The femurs were not fractured in order to simulate post-operative perfect union. Six configurations were created: retrograde nail with standard locking (RS), retrograde nail with advanced locking 'off' (RA-off), retrograde nail with advanced locking 'on' (RA-on), antegrade nail with standard locking (AS), antegrade nail with advanced locking 'off' (AA-off), and antegrade nail with advanced locking 'on' (AA-on). Strain gauges were placed on the medial side of femurs. A 580 N axial load was applied, and the stiffness was measured. Strains were recorded and compared with results from a three-dimensional finite element (FE) model. Experimental axial stiffnesses for RA-off (771.3 N/mm) and RA-on (681.7 N/mm) were similar to intact human cadaveric femurs from previous literature (757 +/- 264 N/mm). Conversely, experimental axial stiffnesses for AS (1168.8N/mm), AA-off (1135.3N/mm), AA-on (1152.1 N/mm), and RS (1294.0 N/mm) were similar to intact synthetic femurs from previous literature (1290 +/- 30 N/mm). There was better agreement between experimental and FE analysis strains for RS (average percentage difference, 11.6 per cent), RA-on (average percentage difference, 11.1 per cent), AA-off (average percentage difference, 13.4 per cent), and AA-on (average percentage difference, 16.0 per cent), than for RA-off (average percentage difference, 33.5 per cent) and AS (average percentage difference, 32.6 per cent). FE analysis was more predictive of strains in the proximal and middle sections of the femur-nail construct than the distal. The results mimicked post-operative clinical stability at low static axial loads once fracture healing begins to occur.
引用
收藏
页码:303 / 314
页数:12
相关论文
共 33 条
[1]   TORSIONAL DEFORMITY AFTER INTRAMEDULLARY NAILING OF FEMORAL-SHAFT FRACTURES - MEASUREMENT OF ANTEVERSION ANGLES IN 110 PATIENTS [J].
BRATEN, M ;
TERJESEN, T ;
ROSSVOLL, I .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (05) :799-803
[2]   Finite element analysis of a femoral retrograde intramedullary nail subject to gait loading [J].
Cheung, G ;
Zalzal, P ;
Bhandari, M ;
Spelt, JK ;
Papini, M .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (02) :93-108
[3]   Mechanical validation of whole bone composite femur models [J].
Cristofolini, L ;
Viceconti, M ;
Cappello, A ;
Toni, A .
JOURNAL OF BIOMECHANICS, 1996, 29 (04) :525-535
[4]   Mechanical validation of whole bone composite tibia models [J].
Cristofolini, L ;
Viceconti, M .
JOURNAL OF BIOMECHANICS, 2000, 33 (03) :279-288
[5]  
Danckwardt-Lilliestrom G, 1970, Acta Orthop Scand Suppl, V134, P1
[6]   Changes in strain distribution of loaded proximal femora caused by different types of cementless femoral stems [J].
Decking, Ralf ;
Puhl, Wolfhart ;
Simon, Ulrich ;
Claes, Lutz E. .
CLINICAL BIOMECHANICS, 2006, 21 (05) :495-501
[7]   Artificial composite bone as a model of human trabecular bone:: The implant-bone interface [J].
Grant, J. A. ;
Bishop, N. E. ;
Goetzen, N. ;
Sprecher, C. ;
Honl, M. ;
Morlock, M. M. .
JOURNAL OF BIOMECHANICS, 2007, 40 (05) :1158-1164
[8]   Structural properties of a new design of composite replicate femurs and tibias [J].
Heiner, AD ;
Brown, TD .
JOURNAL OF BIOMECHANICS, 2001, 34 (06) :773-781
[9]  
HEINER AD, 2003, T 29 ANN M SOC BIOM, P702
[10]   ADAPTIVE BONE-REMODELING THEORY APPLIED TO PROSTHETIC-DESIGN ANALYSIS [J].
HUISKES, R ;
WEINANS, H ;
GROOTENBOER, HJ ;
DALSTRA, M ;
FUDALA, B ;
SLOOFF, TJ .
JOURNAL OF BIOMECHANICS, 1987, 20 (11-12) :1135-1150