Spin transport and polarimetry in the beam delivery system of the international linear collider

被引:7
作者
Beckmann, M. [1 ,2 ]
List, J. [1 ]
Vauth, A. [1 ,2 ]
Vormwald, B. [1 ,2 ]
机构
[1] DESY, D-22607 Hamburg, Germany
[2] Univ Hamburg, Inst Expt Phys, D-22761 Hamburg, Germany
关键词
Instrumentation for particle accelerators and storage rings - high energy (linear accelerators; synchrotrons); Accelerator modelling and simulations (multi-particle dynamics single-particle dynamics);
D O I
10.1088/1748-0221/9/07/P07003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Polarised electron and positron beams are key ingredients to the physics programme of future linear colliders. Due to the chiral nature of weak interactions in the Standard Model and possibly beyond - the knowledge of the luminosity-weighted average beam polarisation at the e(+)e(-) interaction point is of similar importance as the knowledge of the luminosity and has to be controlled to permille-level precision in order to fully exploit the physics potential. The current concept to reach this challenging goal combines measurements from Laser-Compton polarimeters before and after the interaction point with measurements at the interaction point. A key element for this enterprise is the understanding of spin-transport effects between the polarimeters and the interaction point as well as collision effects. We show that without collisions, the polarimeters can be cross-calibrated to 0.1 %, and we discuss in detail the impact of collision effects and beam parameters on the polarisation value relevant for the interpretation of the e(+)e(-) collision data.
引用
收藏
页数:32
相关论文
共 53 条
[1]   High-precision measurement of the left-right Z boson cross-section asymmetry [J].
Abe, K ;
Abe, K ;
Abe, T ;
Adam, I ;
Akimoto, H ;
Aston, D ;
Baird, KG ;
Baltay, C ;
Band, HR ;
Barklow, TL ;
Bauer, JM ;
Bellodi, G ;
Berger, R ;
Blaylock, G ;
Bogart, JR ;
Bower, GR ;
Brau, JE ;
Breidenbach, M ;
Bugg, WM ;
Burke, D ;
Burnett, TH ;
Burrows, PN ;
Calcaterra, A ;
Cassell, R ;
Chou, A ;
Cohn, HO ;
Coller, JA ;
Convery, MR ;
Cook, V ;
Cowan, RF ;
Crawford, G ;
Damerell, CJS ;
Daoudi, M ;
Dasu, S ;
de Groot, N ;
de Sangro, R ;
Dong, DN ;
Doser, M ;
Dubois, R ;
Erofeeva, I ;
Eschenburg, V ;
Etzion, E ;
Fahey, S ;
Faiciai, D ;
Fernandez, JP ;
Fero, MJ ;
Flood, K ;
Frey, R ;
Hart, EL ;
Hasuko, K .
PHYSICAL REVIEW LETTERS, 2000, 84 (26) :5945-5949
[2]   Forward instrumentation for ILC detectors [J].
Abramowicz, H. ;
Abusleme, A. ;
Afanaciev, K. ;
Aguilar, J. ;
Ambalathankandy, P. ;
Bambade, P. ;
Bergholz, M. ;
Bozovic-Jelisavcic, I. ;
Castro, E. ;
Chelkov, G. ;
Coca, C. ;
Daniluk, W. ;
Dragone, A. ;
Dumitru, L. ;
Elsener, K. ;
Emeliantchik, I. ;
Fiutowski, T. ;
Gostkin, M. ;
Grah, C. ;
Grzelak, G. ;
Haller, G. ;
Henschel, H. ;
Ignatenko, A. ;
Idzik, M. ;
Ito, K. ;
Jovin, T. ;
Kielar, E. ;
Kotula, J. ;
Krumstein, Z. ;
Kulis, S. ;
Lange, W. ;
Lohmann, W. ;
Levy, A. ;
Moszczynski, A. ;
Nauenberg, U. ;
Novgorodova, O. ;
Ohlerich, M. ;
Orlande, M. ;
Oleinik, G. ;
Oliwa, K. ;
Olshevski, A. ;
Pandurovic, M. ;
Pawlik, B. ;
Przyborowski, D. ;
Sato, Y. ;
Sadeh, I. ;
Sailer, A. ;
Schmidt, R. ;
Schumm, B. ;
Schuwalow, S. .
JOURNAL OF INSTRUMENTATION, 2010, 5
[3]  
Adolphsen C., SLACPUB12751
[4]  
Angal-Kalinin D., EX SUMM WORKSH POL B
[5]  
[Anonymous], 2013, ARXIV13078102, V2
[6]  
[Anonymous], 2013, ARXIV13078102, V3.11
[7]  
[Anonymous], 1964, Soviet Physics Doklady
[8]  
[Anonymous], 2013, ARXIV13078102, V4
[9]  
[Anonymous], ARXIV13078102
[10]  
[Anonymous], 2013, ARXIV13078102, V1