Rapid and simple multi-analyte LC-MS/MS method for the determination of benzodiazepines and Z-hypnotic drugs in blood samples: Development, validation and application based on three years of toxicological analyses

被引:20
作者
Banaszkiewicz, Laura [1 ]
Wozniak, Mateusz Kacper [1 ]
Kata, Marzena [2 ]
Domagalska, Ewa [2 ]
Wiergowski, Marek [2 ]
Szpiech, Beata [2 ]
Kot-Wasik, Agata [1 ]
机构
[1] Gdansk Univ Technol, Fac Chem, Dept Analyt Chem, 11-12 Narutowicza Str, PL-80233 Gdansk, Poland
[2] Med Univ Gdansk, Fac Med, Dept Forens Med, 3A Marii Sklodowskiej Curie Str, PL-80210 Gdansk, Poland
关键词
Benzodiazepines; Blood; Drug analysis; LC-MS/MS; Liquid-liquid extraction; Z-drugs; TANDEM MASS-SPECTROMETRY; LIQUID-LIQUID-EXTRACTION; WHOLE-BLOOD; DESIGNER BENZODIAZEPINES; METABOLITES; QUANTIFICATION; ZOPICLONE; ZOLPIDEM; ABUSE; ASSAY;
D O I
10.1016/j.jpba.2020.113569
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Benzodiazepines (BZDs) and Z-drugs have been particularly important treatments for sleeping and anxiety disorders for many years. However, recently, a number of new benzodiazepines (named designer benzodiazepines, DBZDs) were synthesised, but some of them have never been used in the clinic; they reached the black drug market as new psychoactive substances and are used for recreational purposes. The abuse of these substances has led to many crimes and even deaths. Therefore, it is necessary to develop new methods for their quantification for forensic and clinical toxicology. A liquid chromatography-tandem mass spectrometry-based method was developed for the simultaneous determination of 20 classical BZDS, 4 DBZDs and 3 Z-hypnotic drugs in human whole blood. As a sample preparation step, liquid-liquid extraction requiring the use of only 0.5 mL of blood sample and 1 mL of extraction solvent was applied. The selectivity, linearity, carry-over effects, limits of detection (LOD) and quantification (LOQ), precision, accuracy (both intra- and inter-day assays) and recovery were evaluated for validation. Calibration curves were linear with r values > 0.98. The LODs ranged from 0.01 to 0.33, and the LOQs were assumed to be 1 ng/mL. Inter-day precisions and accuracies were in the ranges of 87.8% - 108.5% and 1.8% - 11.2%, respectively. The recovery values ranged from 81.0% to 106.7%. The developed method proved to be sensitive, specific, simple, and fast and can be quickly modified and expanded for new compounds by the optimization of MRM. The method was applied for analysis of blood samples in 145 toxicological cases over a three-year study (2017 - 2019), which allowed us to obtain information on the prevalence of the use of these substances. The most frequently determined compounds were nordazepam (87 cases; 60%), diazepam (81 cases; 55.9%), temazepam (72 cases; 49.7%), oxazepam (56 cases; 38.7%), and midazolam (36 cases; 24.8%). The ranges of concentrations were wide and are presented as box plots. The results were used for the preparation of medico-legal opinions, which proved the utility of the method for routine toxicology analyses. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:11
相关论文
共 24 条
[2]   Drugs and chronic alcohol abuse in drivers [J].
Appenzeller, BMR ;
Schneider, S ;
Yegles, M ;
Maul, A ;
Wennig, R .
FORENSIC SCIENCE INTERNATIONAL, 2005, 155 (2-3) :83-90
[3]   Development and application of a multi-component LC-MS/MS method for determination of designer benzodiazepines in urine [J].
Bergstrand, Madeleine Pettersson ;
Helander, Anders ;
Beck, Olof .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1035 :104-110
[4]   Gas chromatography-tandem mass spectrometry assay for the quantification of four benzodiazepines and citalopram in eleven postmortem rabbit fluids and tissues, with application to animal and human samples [J].
Cartiser, N. ;
Bevalot, F. ;
Le Meur, C. ;
Gaillard, Y. ;
Malicier, D. ;
Hubert, N. ;
Guitton, J. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (27) :2909-2918
[5]   New benzodiazepines for sedation [J].
Cornett, Elyse M. ;
Novitch, Matthew B. ;
Brunk, Andrew J. ;
Davidson, Kelly S. ;
Menard, Bethany L. ;
Urman, Richard D. ;
Kaye, Alan D. .
BEST PRACTICE & RESEARCH-CLINICAL ANAESTHESIOLOGY, 2018, 32 (02) :149-164
[6]  
Dåderman AM, 1999, J AM ACAD PSYCHIATRY, V27, P83
[7]   Development and validation of a fast ionic liquid-based dispersive liquid-liquid microextraction procedure combined with LC-MS/MS analysis for the quantification of benzodiazepines and benzodiazepine-like hypnotics in whole blood [J].
De Boeck, Marieke ;
Missotten, Sophie ;
Dehaen, Wim ;
Tytgat, Jan ;
Cuypers, Eva .
FORENSIC SCIENCE INTERNATIONAL, 2017, 274 :44-54
[8]   Determination of 14 benzodiazepines and hydroxy metabolites, zaleplon and zolpidem as tert-butyldimethylsilyl derivatives compared with other common silylating reagents in whole blood by gas chromatography-mass spectrometry [J].
Gunnar, T ;
Ariniemi, K ;
Lillsunde, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 818 (02) :175-189
[9]   Blood concentrations of new designer benzodiazepines in forensic cases [J].
Hoiseth, Gudrun ;
Tuv, Silja Skogstad ;
Karinen, Ritva .
FORENSIC SCIENCE INTERNATIONAL, 2016, 268 :35-38
[10]   Validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous determination of 26 benzodiazepines and metabolites, zolpidem and zopiclone, in blood, urine, and hair [J].
Laloup, M ;
Fernandez, MDR ;
De Boeck, G ;
Wood, M ;
Maes, V ;
Samyn, N .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2005, 29 (07) :616-626