Influence of muscle fibre shortening on estimates of conduction velocity and spectral frequencies from surface electromyographic signals

被引:26
作者
Schulte, E [1 ]
Farina, D
Merletti, R
Rau, G
Disselhorst-Klug, C
机构
[1] Helmholtz Inst, Inst Biomed Technol, Aachen, Germany
[2] Politecn Torino, Dipartimento Elettron, Lab Ingn Sistema Neuromuscolare, Turin, Italy
关键词
surface EMG; dynamic EMG; spatial filtering; EMG modelling;
D O I
10.1007/BF02350988
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The study of surface electromyographic (EMG) signals under dynamic contractions is becoming increasingly important. However, knowledge of the methodological issues that may affect such analysis is still limited. The aim of the study was to analyse the effect of fibre shortening on estimates of conduction velocity (CV) and mean power spectral frequency (MNF) from surface EMG signals. Single fibre action potentials were simulated, as detected by commonly used spatial filters, for different fibre lengths. No physiological modifications were included with changes in fibre length, and thus only geometrical artifacts related to fibre shortening were investigated. The simulation results showed that the dependence of CV and MNF on fibre shortening is affected by the fibre location, electrode position and the spatial filter applied. With shortening of up to 50% for a fibre of 50 mm semi-length, the variations in CV and MNF estimates with shortening in bipolar recordings were 0.5% (CV) and 0.7% (MNF) for superficial fibres, and 3.6% and 5.1% for deeper fibres. Using the longitudinal double differential filter, under the same conditions, the percent variation was 0% and 0.2%, and 24.7% and 15.8%, respectively. The main conclusions were, first, muscle fibre shortening can significantly affect estimates of CV and MNF, especially for short fibre lengths. However, for long (semi-length >50 mm) and superficial fibres, this effect is limited for shortenings of up to 50% of the initial fibre length. Secondly, CV and MNF are almost equally affected by changes in muscle length; and, thirdly, sensitivity to fibre shortening depends on the spatial filter applied for signal detection.
引用
收藏
页码:477 / 486
页数:10
相关论文
共 55 条
[1]   Simulation analysis of the ability to estimate motor unit propagation velocity non-invasively by different two-channel methods and types of multi-electrodes [J].
Arabadzhiev, TI ;
Dimitrov, GV ;
Dimitrova, NA .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2003, 13 (05) :403-415
[2]  
ARENDTNIELSEN L, 1992, ELECTROEN CLIN NEURO, V85, P1428
[3]   Time-frequency analysis of surface myoelectric signals during athletic movement - Studying muscle activation and fatigue during propulsion of a racing wheelchair [J].
Balestra, G ;
Frassinelli, S ;
Knaflitz, M ;
Molinari, F .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2001, 20 (06) :106-115
[4]   Clinician's view: Dynamic EMG [J].
Benedetti, MG .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2001, 20 (06) :33-34
[5]   EMG-based measures of fatigue during a repetitive squat exercise - Assessment of dynamic conditions can provide information about compensatory muscle function in ACL patients [J].
Bonato, P ;
Cheng, MSS ;
Gonzales-Cueto, J ;
Leardini, A ;
O'Connor, J ;
Roy, SH .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2001, 20 (06) :133-143
[6]  
Brown T, 1996, MUSCLE NERVE, V19, P1493, DOI 10.1002/(SICI)1097-4598(199611)19:11<1493::AID-MUS17>3.0.CO
[7]  
2-U
[8]   The effects of four time-varying factors on the mean frequency of a myoelectric signal [J].
Cechetto, AD ;
Parker, PA ;
Scott, RN .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2001, 11 (05) :347-354
[9]   Simulation analysis of the ability of different types of multi-electrodes to increase selectivity of detection and to reduce cross-talk [J].
Dimitrov, GV ;
Disselhorst-Klug, C ;
Dimitrova, NA ;
Schulte, E ;
Rau, G .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2003, 13 (02) :125-138
[10]   Fundamentals of power spectra of extracellular potentials produced by a skeletal muscle fibre of finite length Part II: Effect of parameters altering with functional state [J].
Dimitrov, GV ;
Dimitrova, NA .
MEDICAL ENGINEERING & PHYSICS, 1998, 20 (09) :702-707