Intra-aneurysm sac pressure - The holy grail of endoluminal grafting of AAA

被引:39
作者
Gawenda, M [1 ]
Heckenkamp, J [1 ]
Zaehringer, M [1 ]
Brunkwall, J [1 ]
机构
[1] Univ Cologne, Vasc Ctr, Dept Visceral & Vasc Surg, D-50924 Cologne, Germany
关键词
aneurysm sac pressure; stent graft; open surgery;
D O I
10.1053/ejvs.2002.1662
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: to relate intra-aneurysm sac pressure during endoluminal AAA repair to early and late endoleak, as well as to the aneurysm size upon follow-up. Design: prospective clinical investigation. Methods and patients: in 46 patients who had their AAAs treated by a stent graft (group I) intra-operative pressure measurement was performed (aorto uni-iliac stent grafts: 25 cases, bifurcated stent grafts: 21 cases). In 18 patients-with open repair (group II) flow in the inferior mesenteric artery, and the pressure in the aneurysm sac was measured, before and after aortic and iliac cross clamping. Values are given in median with range. Results: in group I, complete exclusion of AAA (no endoleak on intra-operative control angiogram) resulted in a statistically significant decrease in mean sac pressure from 74 (55-101) to 47 (4-104) mmHg. Pulse pressure reduced from 67 (34-103) to 8 (0-74) mmHg. In 11 patients a proximal type I endoleak was sealed by balloon modeling, after which the mean sac pressure reduced from 63 (14-91) to 52 (4-74) mmHg (n.s. versus patients with primary seal). Intra-operative pressure did not correlate with change in AAA diameter during twelve months follow-up. In group II, cross clamping of the proximal aorta significantly reduced mean sac pressure to 32 (21-55) mmHg, and the pulse pressure to 0 (0-13) mmHg (p < 0.05). Subsequent cross clamping of the iliac arteries did not significantly change the pressures. Conclusions: measurement of intra-aneurysm sac pressure can help to detect and treat endoleaks during endoluminal grafting. However, the intra-operative sac pressure did not predict the fate of aneurysm during follow up. Compared to open repair of AAA, the sac pressure after endoluminal grafting remains significantly higher, in relation to pulse pressure.
引用
收藏
页码:139 / 145
页数:7
相关论文
共 47 条
[1]   Abdominal aortic aneurysm measurements for endovascular repair: Intra- and interobserver variability of CT measurements [J].
Aarts, NJM ;
Schurink, GWH ;
Kool, LJS ;
Bode, PJ ;
van Baalen, JM ;
Hermans, J ;
van Bockel, JH .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1999, 18 (06) :475-480
[2]   Diagnosis and treatment of inferior mesenteric arterial endoleaks after endovascular repair of abdominal aortic aneurysms [J].
Baum, RA ;
Carpenter, JP ;
Tuite, CM ;
Velazquez, OC ;
Soulen, MC ;
Barker, CF ;
Golden, MA ;
Pyeron, AM ;
Fairman, RM .
RADIOLOGY, 2000, 215 (02) :409-413
[3]   Aneurysm pressure following endovascular exclusion [J].
Chuter, T ;
Ivancev, K ;
Malina, M ;
Resch, T ;
Brunkwall, J ;
Lindblad, B ;
Risberg, B .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 13 (01) :85-87
[4]   Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repair [J].
Chuter, TAM ;
Risberg, B ;
Hopkinson, BR ;
Wendt, G ;
Scott, RAP ;
Walker, PJ ;
Viscomi, S ;
White, G .
JOURNAL OF VASCULAR SURGERY, 1996, 24 (04) :655-666
[5]  
Ermis C, 2000, J ENDOVASC THER, V7, P441, DOI 10.1583/1545-1550(2000)007<0441:DSEOEL>2.0.CO
[6]  
2
[7]  
Faries PL, 1997, J ENDOVASC SURG, V4, P290, DOI 10.1583/1074-6218(1997)004<0290:AEMFTA>2.0.CO
[8]  
2
[9]  
Gilling-Smith G, 1999, J ENDOVASC SURG, V6, P305, DOI 10.1583/1074-6218(1999)006<0305:EAEARD>2.0.CO
[10]  
2