CONTINUOUS SCINTILLATOR DETECTOR BLOCKS FOR SIMULTANEOUS PET-MR IMAGING OF THE HUMAN BRAIN

被引:0
作者
Rato Mendes, Pedro [1 ]
机构
[1] CIEMAT, Avda Complutense 22, Madrid 28040, Spain
来源
ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS | 2010年 / 5卷
关键词
GUIDED ATTENUATION; RESOLUTION; ARRAY; LSO;
D O I
暂无
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Continuous scintillator detector blocks have several advantages over pixelated designs, presenting a larger active volume and a lower cost with comparable or better energy and spatial resolutions. In this paper we describe the operation of continuous detector blocks for positron emission tomography (PET) and their suitability for multimodality imaging operating inside a magnetic resonance (MR) scanner. This detector technology is being used on a full-scale clinical scanner for human brain PET studies presently under development at Ciemat. Results will be presented on the laboratory characterization of monolithic scintillators coupled to APD matrices with ASIC readout, including images of point sources from a prototype dual-head demonstrator illustrating the potential of continuous scintillator detector blocks for high-resolution PET-MR imaging.
引用
收藏
页码:121 / 127
页数:7
相关论文
共 16 条
  • [1] Characterization and quality control of avalanche photodiode arrays for the Clear-PEM detector modules
    Abreu, Conceicao
    Amaral, Pedro
    Carrico, Bruno
    Ferreira, Miguel
    Luyten, Joan
    Moura, Rui
    Ortigao, Catarina
    Rato, Pedro
    Varela, Joao
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01) : 19 - 22
  • [2] SCINTILLATION CAMERA
    ANGER, HO
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1958, 29 (01) : 27 - 33
  • [3] Bailey DL, 2005, POSITRON EMISSION TO, V2
  • [4] Beyer T, 2000, J NUCL MED, V41, P1369
  • [5] Neural network-based position estimators for PET detectors using monolithic LSO blocks
    Bruyndonckx, P
    Léonard, S
    Tavernier, S
    Lemaître, C
    Devroede, O
    Wu, YB
    Krieguer, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2520 - 2525
  • [6] Spatial resolution and depth-of-interaction studies with a PET detector module composed of LSO and an APD array
    Fremout, AAR
    Chen, RR
    Bruyndonckx, P
    Tavernier, SPK
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 131 - 138
  • [7] Hendee W R, 1989, Radiographics, V9, P1155
  • [8] Advances in high-field magnetic resonance imaging
    Hu, XP
    Norris, DG
    [J]. ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2004, 6 : 157 - 184
  • [9] Simultaneous PET-MRI:: a new approach for functional and morphological imaging
    Judenhofer, Martin S.
    Wehrl, Hans F.
    Newport, Danny F.
    Catana, Ciprian
    Siegel, Stefan B.
    Becker, Markus
    Thielscher, Axel
    Kneilling, Manfred
    Lichy, Matthias P.
    Eichner, Martin
    Klingel, Karin
    Reischl, Gerald
    Widmaier, Stefan
    Roecken, Martin
    Nutt, Robert E.
    Machulla, Hans-Juergen
    Uludag, Kamil
    Cherry, Simon R.
    Claussen, Claus D.
    Pichler, Bernd J.
    [J]. NATURE MEDICINE, 2008, 14 (04) : 459 - 465
  • [10] Latest advances in molecular imaging instrumentation
    Pichler, Bernd J.
    Wehrl, Hans F.
    Judenhofer, Martin S.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2008, 49 : 5S - 23S